DUAL-WAVELENGTH RATIOMETRIC FLUORESCENCE MEASUREMENT OF THE MEMBRANE DIPOLE POTENTIAL

被引:224
|
作者
GROSS, E [1 ]
BEDLACK, RS [1 ]
LOEW, LM [1 ]
机构
[1] UNIV CONNECTICUT, CTR HLTH, SCH MED, DEPT PHYSIOL, FARMINGTON, CT 06030 USA
关键词
D O I
10.1016/S0006-3495(94)80471-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The electrostatic potentials associated with cell membranes include the transmembrane potential (Delta psi), the surface potential (psi(S)), and the dipole potential (psi(D)). psi(D), which originates from oriented dipoles at the surface of the membrane, rises steeply just within the membrane to similar to 300 mV. Here we show that the potential-sensitive fluorescent dye 1-(3-sulfonatopropyl)-4-[beta[2-(di-n-octylamino)-6-naphthyl]vinyl]pyridinium betaine (di-8-ANEPPS) can be used to measure changes in the intramembrane dipole potential. Increasing the content of cholesterol and 6-ketocholestanol (KC), which are known to increase psi(D) in the bilayer, results in an increase in the ratio, R, of the dye fluorescence excited at 440 nm to that excited at 530 nm in a lipid vesicle suspension; increasing the content of phloretin, which lowers psi(D), decreases R. Control experiments show that the ratio is insensitive to changes in the membrane's microviscosity. The lack of an isosbestic point in the fluorescence excitation and emission spectra of the dye at various concentrations of KC and phloretin argues against 1:1 chemical complexation between the dye and KC or phloretin. The macromolecular nonionic surfactant Pluronic F127 catalyzes the insertion of KC and phloretin into lipid vesicle and cell membranes, permitting convenient and controlled modulation of dipole potential. The sensitivity of R to psi(D) is 10-fold larger than to Delta psi, whereas it is insensitive to changes in psi(S). This can be understood in terms of the location of the dye chromophore with respect to the electric field profile associated with each of these potentials. These results suggest that the gradient in dipole potential occurs over a span less than or equal to 5 Angstrom, a short distance below the membrane-water interface. These approaches are easily adaptable to study the influence of dipole potentials on cell membrane physiology.
引用
收藏
页码:208 / 216
页数:9
相关论文
共 50 条
  • [1] DUAL-WAVELENGTH RATIOMETRIC FLUORESCENCE MEASUREMENT OF THE MEMBRANE DIPOLE POTENTIAL
    GROSS, E
    BEDLACK, RS
    LOEW, LM
    BIOPHYSICAL JOURNAL, 1994, 66 (02) : A387 - A387
  • [2] DUAL-WAVELENGTH RATIOMETRIC FLUORESCENCE MEASUREMENTS OF MEMBRANE-POTENTIAL
    MONTANA, V
    FARKAS, DL
    LOEW, LM
    BIOCHEMISTRY, 1989, 28 (11) : 4536 - 4539
  • [3] Dual-wavelength ratiometric fluorescence measurement of transmembrane potential and intramembrane dipole potential in single, N1E-115 neuroblastoma cells
    Zhang, J
    Davidson, RM
    Wei, MD
    Loew, LM
    BIOPHYSICAL JOURNAL, 1997, 72 (02) : MPO59 - MPO59
  • [4] QUANTIFICATION OF THE HEMATOPORPHYRIN DERIVATIVE BY FLUORESCENCE MEASUREMENT USING DUAL-WAVELENGTH EXCITATION AND DUAL-WAVELENGTH DETECTION
    SINAASAPPEL, M
    STERENBORG, HJCM
    APPLIED OPTICS, 1993, 32 (04): : 541 - 548
  • [5] Comparison of excitation and emission ratiometric fluorescence methods for quantifying the membrane dipole potential
    Vitha, Mark F.
    Clarke, Ronald J.
    BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2007, 1768 (01): : 107 - 114
  • [6] Dual-Wavelength Ratiometric Electrochemiluminescence Immunosensor for Cardiac Troponin I Detection
    Ye, Jing
    Zhu, Liping
    Yan, Mengxia
    Zhu, Qiuju
    Lu, Qingqing
    Huang, Jianshe
    Cui, Hua
    Yang, Xiurong
    ANALYTICAL CHEMISTRY, 2019, 91 (02) : 1524 - 1531
  • [7] Measurement of rainfall by dual-wavelength microwave attenuation
    Holt, AR
    Goddard, JWF
    Upton, GJG
    Willis, MJ
    Rahimi, AR
    Baxter, PD
    Collier, CG
    ELECTRONICS LETTERS, 2000, 36 (25) : 2099 - 2101
  • [8] Dual-wavelength Fourier ptychographic microscopy for topographic measurement
    Hao, Qun
    Lin, Chao
    Hu, Yao
    Yu, Qian
    Lv, Jiahang
    Zheng, Chuanjian
    Zhang, Shaohui
    Xu, Chuheng
    Song, Ci
    OPTICS EXPRESS, 2024, 32 (04): : 6684 - 6699
  • [9] Photoacoustic temperature measurement based on dual-wavelength method
    Liao Yu
    Jian Xiao-Hua
    Cui Yao-Yao
    Zhang Qi
    ACTA PHYSICA SINICA, 2017, 66 (11)
  • [10] Electrochemiluminescence Resonance Energy Transfer System for Dual-Wavelength Ratiometric miRNA Detection
    Huo, Xiao-Lei
    Zhang, Nan
    Yang, Hui
    Xu, Jing-Juan
    Chen, Hong-Yuan
    ANALYTICAL CHEMISTRY, 2018, 90 (22) : 13723 - 13728