Comparison of excitation and emission ratiometric fluorescence methods for quantifying the membrane dipole potential

被引:40
|
作者
Vitha, Mark F.
Clarke, Ronald J. [1 ]
机构
[1] Univ Sydney, Sch Chem, Sydney, NSW 2006, Australia
[2] Drake Univ, Dept Chem, Des Moines, IA 50311 USA
来源
基金
澳大利亚研究理事会;
关键词
lipid vesicle; voltage-sensitive styryl dye; emission ratio; excitation ratio; cholesterol; dipole potential;
D O I
10.1016/j.bbamem.2006.06.022
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
We are interested in developing fluorescence methods for quantifying lateral variations in the dipole potential across cell surfaces. Previous work in this laboratory showed that the ratio of fluorescence intensities of the voltage-sensitive dye di-8-ANEPPS using excitation wavelengths at 420 and 520 nm correlates well with measurements of the dipole potential. In the present work we evaluate the use of di-8-ANEPPS and an emission ratiometric method for measuring dipole potentials, as Bullen and Saggau (Biophys. J. 65 (1999) 2272-2287) have done to follow changes in the membrane potential in the presence of an externally applied field. Emission ratiometric methods have distinct advantages over excitation methods when applied to fluorescence microscopy because only a single wavelength is needed for excitation. We found that unlike the excitation ratio, the emission ratio does not correlate with the dipole potential of vesicles made from different lipids. A difference in the behaviour of the emission ratio in saturated compared to unsaturated lipid vesicles was noted. Furthermore, the emission ratio did not respond in the same way as the excitation ratio when cholesterol, 6-ketocholestanol, 7-ketocholesterol, and phloretin were added to dimyristoylphosphatidylcholine (DMPC) vesicles. We attribute the lack of correlation between the emission ratio and the dipole potential to simultaneous changes in membrane fluidity caused by changes in membrane composition, which do not occur when the electric field is externally applied as in the work of Bullen and Saggau. Di-8-ANEPPS can, thus, only be used via an excitation ratiometric method to quantify the dipole potential. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:107 / 114
页数:8
相关论文
共 50 条
  • [1] DUAL-WAVELENGTH RATIOMETRIC FLUORESCENCE MEASUREMENT OF THE MEMBRANE DIPOLE POTENTIAL
    GROSS, E
    BEDLACK, RS
    LOEW, LM
    BIOPHYSICAL JOURNAL, 1994, 66 (02) : A387 - A387
  • [2] DUAL-WAVELENGTH RATIOMETRIC FLUORESCENCE MEASUREMENT OF THE MEMBRANE DIPOLE POTENTIAL
    GROSS, E
    BEDLACK, RS
    LOEW, LM
    BIOPHYSICAL JOURNAL, 1994, 67 (01) : 208 - 216
  • [3] Membrane Dipole Potential as Measured by Ratiometric 3-Hydroxyflavone Fluorescence Probes: Accounting for Hydration Effects
    Gora M`Baye
    Vasyl V. Shynkar
    Andrey S. Klymchenko
    Yves Mély
    Guy Duportail
    Journal of Fluorescence, 2006, 16 : 35 - 42
  • [4] Membrane dipole potential as measured by ratiometric 3-hydroxyflavone fluorescence probes:: Accounting for hydration effects
    M'Baye, G
    Shynkar, VV
    Klymchenko, AS
    Mély, Y
    Duportail, G
    JOURNAL OF FLUORESCENCE, 2006, 16 (01) : 35 - 42
  • [5] Ratiometric fluorescence measurements and imaging of the dipole potential in cell plasma membranes
    Shynkar, VV
    Klymchenko, AS
    Duportail, G
    Demchenko, AP
    Mély, Y
    BIOPHOTONICS MICRO-AND NANO-IMAGING, 2004, 5462 : 118 - 130
  • [6] Potential of fluorescence excitation emission matrix (FEEM) analysis for foulant characterisation in membrane bioreactors (MBRs)
    Subhi, Nashida
    Henderson, Rita
    Stuetz, Richard M.
    Chen, Vicki
    Le-Clech, Pierre
    DESALINATION AND WATER TREATMENT, 2011, 34 (1-3) : 167 - 172
  • [7] DUAL-WAVELENGTH RATIOMETRIC FLUORESCENCE MEASUREMENTS OF MEMBRANE-POTENTIAL
    MONTANA, V
    FARKAS, DL
    LOEW, LM
    BIOCHEMISTRY, 1989, 28 (11) : 4536 - 4539
  • [8] Fluorescence quotient of excitation-emission matrices as a potential indicator of organic matter behavior in membrane bioreactors
    Xiao, Kang
    Liang, Shuai
    Xiao, Aihua
    Lei, Ting
    Tan, Jihua
    Wang, Xiaomao
    Huang, Xia
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2018, 4 (02) : 281 - 290
  • [9] A Comparison of Second-Order Calibration Methods Applied to Excitation-Emission Matrix Fluorescence Data
    Chen, Hui
    Lin, Zan
    Wu, Tong
    Tan, Chao
    JOURNAL OF CHEMISTRY, 2014, 2014
  • [10] COMPARISON OF METHODS FOR QUANTIFYING THE HYDROLYTIC POTENTIAL OF CELLULASE ENZYMES
    CHAN, M
    BREUIL, C
    SCHWALD, W
    SADDLER, JN
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 1989, 31 (04) : 413 - 418