IN-VIVO MEASUREMENT OF WATER DIFFUSION IN THE HUMAN HEART

被引:119
|
作者
EDELMAN, RR
GAA, JC
WEDEEN, VJ
LOH, E
HARE, JM
PRASAD, P
LI, W
机构
[1] MASSACHUSETTS GEN HOSP,BOSTON,MA 02114
[2] BRIGHAM & WOMENS HOSP,DIV CARDIOL,BOSTON,MA 02115
[3] HARVARD UNIV,SCH MED,BOSTON,MA
关键词
DIFFUSION; CARDIAC; MAGNETIC RESONANCE IMAGING; ECHO PLANAR IMAGING;
D O I
10.1002/mrm.1910320320
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Existing magnetic resonance methods for diffusion imaging, including echo planar, are ineffective in the beating heart due to motion-induced signal attenuation. To overcome this problem, we used a diffusion-weighted stimulated echo-echo planar magnetic resonance imaging sequence. The two lobes of the diffusion-sensitizing gradient were synchronized to the same point in successive cardiac cycles in order to fix the cardiac position and avoid bulk motion effects. The apparent diffusion coefficients (ADCs) of the interventricular septum in 12 healthy subjects for diffusion gradients along the x-, y-, and z-directions were 1.40 +/- 0.27, 1.48 +/- 0.35, and 1.78 +/- 0.27 x 10(-3) mm(2)/s. The ADCs of the interventricular septum ina second group of 15 healthy subjects for diffusion gradients along the short axis, horizontal and vertical long axes were 0.92 +/- 0.15, 1.50 +/- 0.15, and 1.10 +/- 0.24 x 10(-3) mm(2)/s. Because the ADCs were less than the measured values for skeletal muscle and their standard deviations were low, it seems unlikely that bulk motion effects made the dominant contribution to the measured myocardial ADC for the interventricular septum, although motion and/or susceptibility artifacts frequently degraded measurements in the free wall of the left ventricle. Additional evidence that ADC was not predominantly determined by wall motion was obtained in a third group of patients with various cardiac abnormalities, in whom there was only a weak correlation between ADC and ejection fraction. Although further study is needed to better understand the factors contributing to the myocardial ADC, we hypothesize that the measured diffusional anisotropy in the septum might be explained largely on the basis of myofiber orientation.
引用
收藏
页码:423 / 428
页数:6
相关论文
共 50 条
  • [31] In-Vivo time domain measurement of dielectric properties of human body tissue
    Koyama, Kazunori
    Hirata, Akimasa
    Wang, Jianquing
    Fujiwara, Osamu
    [J]. IEEJ Transactions on Fundamentals and Materials, 2010, 130 (12): : 1087 - 1091
  • [32] MEASUREMENT OF CARBAMAZEPINE AND CARBAMAZEPINE EPOXIDE IN THE HUMAN BRAIN USING IN-VIVO MICRODIALYSIS
    SCHEYER, RD
    DURING, MJ
    SPENCER, DD
    CRAMER, JA
    MATTSON, RH
    [J]. NEUROLOGY, 1994, 44 (08) : 1469 - 1472
  • [33] MEASUREMENT OF PSYCHOACTIVE-DRUGS IN THE HUMAN BRAIN IN-VIVO BY MR SPECTROSCOPY
    KOMOROSKI, RA
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1993, 14 (05) : 1038 - 1042
  • [34] Human Body Communication In-Vivo Measurement Using Different Test Equipment
    Maamir, Fouad
    Touhami, Rachida
    Tedjini, Smail
    Guiatni, Mohamed
    [J]. INTERNATIONAL JOURNAL OF WIRELESS INFORMATION NETWORKS, 2021, 28 (04) : 437 - 450
  • [35] MEASUREMENT OF THE YOUNG MODULE OF THE STRATUM-CORNEUM AND THE HUMAN DERMIS IN-VIVO
    AGACHE, P
    PANISSET, F
    VARCHON, D
    HUMBERT, P
    [J]. ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 1995, 103 (03) : C81 - C81
  • [36] MEASUREMENT IN-VIVO OF TRANSEPIDERMAL MOISTURE LOSS
    BERUBE, GR
    MESSINGE.M
    BERDICK, M
    [J]. SOAP AND CHEMICAL SPECIALITIES, 1970, 46 (07): : 38 - &
  • [37] In-vivo measurement of activated microglia in dementia
    Cagnin, A
    Brooks, DJ
    Kennedy, AM
    Gunn, RN
    Myers, R
    Turkheimer, FE
    Jones, T
    Banati, RB
    [J]. LANCET, 2001, 358 (9280): : 461 - 467
  • [38] PH MEASUREMENT IN-VIVO - EMPLOYMENT IN OBSTETRICS
    BELLEE, H
    KADEN, H
    OELSSNER, W
    [J]. ZEITSCHRIFT FUR GEBURTSHILFE UND PERINATOLOGIE, 1993, 197 (03): : 148 - 149
  • [39] A method for the measurement of toothbrushing forces in-vivo
    Jones, PR
    Raven, S
    Dawson, PL
    [J]. JOURNAL OF DENTAL RESEARCH, 1996, 75 : 1417 - 1417
  • [40] MEASUREMENT OF CALIFORNIUM-252 IN-VIVO
    NEWTON, D
    EAGLE, MC
    [J]. HEALTH PHYSICS, 1972, 23 (06): : 817 - +