IN-VIVO MEASUREMENT OF WATER DIFFUSION IN THE HUMAN HEART

被引:119
|
作者
EDELMAN, RR
GAA, JC
WEDEEN, VJ
LOH, E
HARE, JM
PRASAD, P
LI, W
机构
[1] MASSACHUSETTS GEN HOSP,BOSTON,MA 02114
[2] BRIGHAM & WOMENS HOSP,DIV CARDIOL,BOSTON,MA 02115
[3] HARVARD UNIV,SCH MED,BOSTON,MA
关键词
DIFFUSION; CARDIAC; MAGNETIC RESONANCE IMAGING; ECHO PLANAR IMAGING;
D O I
10.1002/mrm.1910320320
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Existing magnetic resonance methods for diffusion imaging, including echo planar, are ineffective in the beating heart due to motion-induced signal attenuation. To overcome this problem, we used a diffusion-weighted stimulated echo-echo planar magnetic resonance imaging sequence. The two lobes of the diffusion-sensitizing gradient were synchronized to the same point in successive cardiac cycles in order to fix the cardiac position and avoid bulk motion effects. The apparent diffusion coefficients (ADCs) of the interventricular septum in 12 healthy subjects for diffusion gradients along the x-, y-, and z-directions were 1.40 +/- 0.27, 1.48 +/- 0.35, and 1.78 +/- 0.27 x 10(-3) mm(2)/s. The ADCs of the interventricular septum ina second group of 15 healthy subjects for diffusion gradients along the short axis, horizontal and vertical long axes were 0.92 +/- 0.15, 1.50 +/- 0.15, and 1.10 +/- 0.24 x 10(-3) mm(2)/s. Because the ADCs were less than the measured values for skeletal muscle and their standard deviations were low, it seems unlikely that bulk motion effects made the dominant contribution to the measured myocardial ADC for the interventricular septum, although motion and/or susceptibility artifacts frequently degraded measurements in the free wall of the left ventricle. Additional evidence that ADC was not predominantly determined by wall motion was obtained in a third group of patients with various cardiac abnormalities, in whom there was only a weak correlation between ADC and ejection fraction. Although further study is needed to better understand the factors contributing to the myocardial ADC, we hypothesize that the measured diffusional anisotropy in the septum might be explained largely on the basis of myofiber orientation.
引用
收藏
页码:423 / 428
页数:6
相关论文
共 50 条
  • [1] MEASUREMENT OF WATER VAPOR LOSS THROUGH HUMAN NAIL IN-VIVO
    SPRUIT, D
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1971, 56 (05) : 359 - &
  • [2] MEASUREMENT OF HUMAN ESOPHAGEAL TONE IN-VIVO
    MAYRAND, S
    DIAMANT, NE
    [J]. GASTROENTEROLOGY, 1993, 105 (05) : 1411 - 1420
  • [3] IN-VIVO MEASUREMENT OF HUMAN ULNAR STRENGTH
    YOUNG, DR
    [J]. FEDERATION PROCEEDINGS, 1974, 33 (03) : 375 - 375
  • [4] High resolution in-vivo diffusion imaging of the human hippocampus
    Treit, Sarah
    Steve, Trevor
    Gross, Donald W.
    Beaulieu, Christian
    [J]. NEUROIMAGE, 2018, 182 : 479 - 487
  • [5] Diffusion studies of human brain tissue in-vivo by MRI
    Nezamzadeh, M
    Cameron, I
    [J]. MEDICAL PHYSICS, 2005, 32 (07) : 2409 - 2409
  • [6] When perfusion meets diffusion:: in vivo measurement of water permeability in human brain
    Wang, Jiongjiong
    Fernandez-Seara, Maria A.
    Wang, Sumei
    St Lawrence, Keith S.
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2007, 27 (04): : 839 - 849
  • [7] WATER VAPOR DIFFUSION THROUGH HUMAN EPIDERMIS IN-VIVO AT DIFFERENT ENVIRONMENTAL HUMIDITIES AND AFTER SOAKING
    OPPERMAN.C
    HEERD, E
    [J]. PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1970, 318 (01): : 51 - &
  • [8] MEASUREMENT OF YOUNGS MODULUS IN THE IN-VIVO HUMAN VOCAL FOLDS
    TRAN, QT
    GERRATT, BR
    BERKE, GS
    KREIMAN, J
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1993, 102 (08): : 584 - 591
  • [9] Geometrical Scaling for the Measurement of In-Vivo Human Inner Ear
    Yu, Jen-Fang
    Lee, Kun-Che
    Chin, Wei-Chung
    [J]. SENSOR LETTERS, 2012, 10 (5-6) : 1247 - 1251
  • [10] METHOD FOR IN-VIVO MEASUREMENT OF MUCOCILIARY ACTIVITY IN THE HUMAN NOSE
    LINDBERG, S
    RUNER, T
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1994, 103 (07): : 558 - 566