A METHOD FOR DETERMINING PULSE TRANSMISSION TIME

被引:2
|
作者
BUGRAM, R
AKHLAGHIFARSI, H
MARESCH, H
PFURTSCHELLER, G
机构
来源
BIOMEDIZINISCHE TECHNIK | 1994年 / 39卷 / 03期
关键词
BLOOD PRESSURE; PULSE PRESSURE; PULSE TRANSMISSION TIME;
D O I
10.1515/bmte.1994.39.3.51
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Analysis of the transit time of a pulse wave is a possibility for the continuous observation of the changes in blood pressure activity. With invasive procedures, the interval between two notable events on pressure pulse waveforms, which is known as the pulse transit time, is often calculated. Using the second heart sound, the pre-ejection period and the left-ventricular ejection time (systolic time interval) are computed in order to be able to exclude the effect of haemodynamic parameters on aortic pressure increase. Since the use of noninvasive procedures excludes computation of the systolic time interval, and a phonocardiography is also often lacking, a method of relatively quickly determining the time interval between the R-wave of the ECG and the peripheral pulse was developed. The computed pulse transmission time is suitable for studying phasic events and their effects on the mean blood pressure.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 50 条
  • [31] Whole bag method for determining oxygen transmission rate
    Moyls, A.L.
    Transactions of the American Society of Agricultural Engineers, 2004, 47 (01): : 159 - 164
  • [32] Whole bag method for determining oxygen transmission rate
    Moyls, AL
    TRANSACTIONS OF THE ASAE, 2004, 47 (01): : 159 - 164
  • [33] In situ method for determining the transmission loss of noise barriers
    Watts, GR
    APPLIED ACOUSTICS, 1997, 51 (04) : 421 - 438
  • [34] Method for Determining the Intrinsic Parameters of Strip Transmission Lines
    E. A. Lupanova
    S. M. Nikulin
    Measurement Techniques, 2021, 64 : 398 - 404
  • [35] Method for Determining the Intrinsic Parameters of Strip Transmission Lines
    Lupanova, E. A.
    Nikulin, S. M.
    MEASUREMENT TECHNIQUES, 2021, 64 (05) : 398 - 404
  • [36] TRANSMISSION METHOD FOR DETERMINING OPTICAL-CONSTANTS OF METALS
    JOENSEN, P
    IRWIN, JC
    COCHRAN, JF
    CURZON, AE
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1973, 63 (12) : 1556 - 1562
  • [37] Determining the impact pulse at the point of tooth engagement in the driving and driven gears of a transmission
    Mamedov A.F.
    Russian Engineering Research, 2009, 29 (11) : 1081 - 1082
  • [38] TIME TRANSFORMATION METHOD FOR PULSE THERMOGRAPHY
    Muzika, Lukas
    Svantner, Michal
    Moskal, Denis
    28TH INTERNATIONAL CONFERENCE ON METALLURGY AND MATERIALS (METAL 2019), 2019, : 892 - 896
  • [39] PULSE METHOD FOR DETERMINING THERMAL DIFFUSIVITY OF POOR HEAT CONDUCTORS
    EGOROV, BN
    KILESSO, VS
    MEASUREMENT TECHNIQUES-USSR, 1969, (10): : 1375 - &
  • [40] Determining the Best Method for Nellcor Pulse Oximeter Sensor Application
    J A Dawson
    A Saraswat
    L Simionato
    M Thio
    C O F Kamlin
    L Owen
    G M Schmoelzer
    P G Davis
    Pediatric Research, 2011, 70 : 631 - 631