FRACTURE OF THE KNEE ENDOPROSTHESIS - REPORT OF 3 CASES OF TIBIAL COMPONENT FAILURE

被引:0
|
作者
TJORNSTRAND, B [1 ]
LIDGREN, L [1 ]
机构
[1] UNIV LUND HOSP,DEPT ORTHOPAED,S-22185 LUND,SWEDEN
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1985年 / 56卷 / 02期
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
引用
收藏
页码:124 / 126
页数:3
相关论文
共 50 条
  • [1] Stress fracture of the femoral component in total knee replacement: A report of 3 cases
    Wada, M
    Imura, S
    Bo, A
    Baba, H
    Miyazaki, T
    INTERNATIONAL ORTHOPAEDICS, 1997, 21 (01) : 54 - 55
  • [2] Stress fracture of the femoral component in total knee replacement: a report of 3 cases
    M. Wada
    S. Imura
    A. Bo
    H. Baba
    T. Miyazaki
    International Orthopaedics, 1997, 21 : 54 - 55
  • [3] FRACTURE OF POLYETHYLENE TIBIAL COMPONENT IN A TOTAL KNEE REPLACEMENT - A CASE-REPORT
    MOWERY, C
    BOTTE, M
    BRADLEY, G
    ORTHOPEDICS, 1987, 10 (02) : 309 - 313
  • [4] FRACTURE OF THE TIBIAL TRAY FOLLOWING PCA KNEE REPLACEMENT - A REPORT OF 2 CASES
    MARUYAMA, M
    TERAYAMA, K
    SUNOHARA, H
    ADACHI, T
    SUZUKI, S
    FUKUZAWA, T
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1994, 113 (06) : 330 - 333
  • [5] Implant fracture of the Regenerex® modular metal tibial component: A report of three cases
    Rytter, Soren
    Madsen, Frank
    Jepsen, Claus Fink
    Stilling, Maiken
    KNEE, 2019, 26 (05): : 1143 - 1151
  • [6] Early Aseptic Failure of the Tibial Component-Cement Interface in ATTUNE® Total Knee Arthroplasty: A Report of Three Cases
    Murphy, John D.
    Braunlich, Phillip R.
    Judson, William R.
    Harker, John N.
    Baumann, Patricia A.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (12)
  • [7] FRACTURE OF THE METALLIC TIBIAL TRAY FOLLOWING TOTAL KNEE REPLACEMENT - REPORT OF 2 CASES
    SCOTT, RD
    EWALD, FC
    WALKER, PS
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (05): : 780 - 782
  • [8] Tibial component failure mechanisms in total knee arthroplasty
    Berend, ME
    Ritter, MA
    Meding, JB
    Faris, PM
    Keating, EM
    Redelman, R
    Faris, GW
    Davis, KE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) : 26 - 34
  • [9] Catastrophic Failure of the Tibial Component After Total Knee Arthroplasty: Fracture and Dissociation Between the Baseplate and Stem
    Worgul, Christopher A.
    Lentine, Brandon
    Dicken, Quinten G.
    Freccero, David M.
    ARTHROPLASTY TODAY, 2022, 14 : 194 - 198
  • [10] UNICOMPARTMENTAL KNEE REPLACEMENT IN FAILURE OF HIGH TIBIAL OSTEOTOMY FOR MEDIAL GONARTHROSIS - REPORT ON 25 CASES
    CARTIER, P
    SANOUILLER, JL
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1992, 78 : 112 - 114