INTRAOPERATIVE MEASURING OF LEG LENGTH IN TOTAL HIP-ARTHROPLASTY

被引:0
|
作者
ENGELBRECHT, E [1 ]
KLUBER, D [1 ]
HAHN, M [1 ]
机构
[1] UNIV HAMBURG,ZENTRUM BIOMECH PATHOL,OSTEOPATHOL ABT,W-2000 HAMBURG 13,GERMANY
来源
CHIRURG | 1994年 / 65卷 / 11期
关键词
TOTAL HIP ARTHROPLASTY; MEASURING OF LEG LENGTH; LEG LENGTH DISCREPANCY; FEMORAL; ACETABULAR COMPONENT; INCLINATION; ANTEVERSION;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Preservation or restoration of the equal length of both legs after total hip arthroplasty is best achieved by direct intraoperative measurement. The measuring instruments designed for this purpose are presented and their application described for the posterior approach to the hip. The instruments are easy and quick to use. They can also be used for other approaches to the hip and in addition they are a valuable aid when estimating the angles of anteversion and inclination of the acetabular component. The high degree of accuracy and the significant improvement in results when this instrument was used intraoperatively was confirmed by comparison of radiographic measurements of two operation series.
引用
收藏
页码:1034 / 1041
页数:8
相关论文
共 50 条
  • [21] Stability and leg length equality in total hip arthroplasty
    Austin, MS
    Hozack, WJ
    Sharkey, PF
    Rothman, RH
    [J]. JOURNAL OF ARTHROPLASTY, 2003, 18 (03): : 88 - 90
  • [22] Leg Length Discrepancy in Primary Total Hip Arthroplasty
    Pyrko, Peter
    Zuckerman, Joseph
    [J]. BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2016, 74 (01): : 82 - 87
  • [23] Optimizing leg length correction in total hip arthroplasty
    Kenji Fujita
    Tamon Kabata
    Yoshitomo Kajino
    Hiroyuki Tsuchiya
    [J]. International Orthopaedics, 2020, 44 : 437 - 443
  • [24] Leg length discrepancy after total hip arthroplasty
    Maloney, WJ
    Keeney, JA
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (04): : 108 - 110
  • [25] ISOELASTICITY AND TOTAL HIP-ARTHROPLASTY
    SKINNER, HB
    [J]. ORTHOPEDICS, 1991, 14 (03) : 323 - 328
  • [26] REVISION TOTAL HIP-ARTHROPLASTY
    PELLICCI, PM
    WILSON, PD
    SLEDGE, CB
    SALVATI, EA
    RANAWAT, CS
    POSS, R
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1982, (170) : 34 - 41
  • [27] An accurate method for measuring leg length and hip offset in hip arthroplasty
    Huddleston, HD
    [J]. ORTHOPEDICS, 1997, 20 (04) : 331 - 332
  • [28] EFFICACY OF INTRAOPERATIVE CULTURES OBTAINED DURING REVISION TOTAL HIP-ARTHROPLASTY
    PADGETT, DE
    SILVERMAN, A
    SACHJOWICZ, F
    SIMPSON, RB
    ROSENBERG, AG
    GALANTE, JO
    [J]. JOURNAL OF ARTHROPLASTY, 1995, 10 (04): : 420 - 426
  • [29] Intraoperative limb length measurement in total hip arthroplasty
    Naito, M
    Ogata, K
    Asayama, I
    [J]. INTERNATIONAL ORTHOPAEDICS, 1999, 23 (01) : 31 - 33
  • [30] COST-EFFECTIVENESS OF INTRAOPERATIVE AUTOTRANSFUSION IN TOTAL HIP-ARTHROPLASTY SURGERY