REDUCTION OF ARTIFACTS IN MAGNETIC-RESONANCE IMAGES BY USING OPTIMIZED MATERIALS FOR DIAGNOSTIC DEVICES AND IMPLANTS

被引:12
|
作者
FRITZSCHE, S [1 ]
THULL, R [1 ]
HAASE, A [1 ]
机构
[1] UNIV WURZBURG,INST PHYS,LEHRSTUHL EXPTL PHYS 5,W-8700 WURZBURG,GERMANY
来源
BIOMEDIZINISCHE TECHNIK | 1994年 / 39卷 / 03期
关键词
MAGNETIC SUSCEPTIBILITY; ARTIFACTS; BIOMATERIALS; MAGNETIC RESONANCE IMAGING;
D O I
10.1515/bmte.1994.39.3.42
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Differences in magnetic susceptibility, as occur for example at the boundary between implant materials and the surrounding body tissue, result in artefacts and a signal loss in magnetic resonance imaging. By using materials with a magnetic susceptibility matched to the respective environment, it is possible to minimize both artefacts and signal loss. Such materials can be made by combining two materials of different magnetic susceptibility (e.g. diamagnetic and paramagnetic materials) in such a way that the resulting material has the desired effective magnetic susceptibility.
引用
收藏
页码:42 / 46
页数:5
相关论文
共 50 条
  • [31] INSTANT IMAGES OF THE BODY BY MAGNETIC-RESONANCE
    PYKETT, IL
    RZEDZIAN, RR
    MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (06) : 563 - 571
  • [32] COMPUTER VISION ON MAGNETIC-RESONANCE IMAGES
    MENHARDT, W
    SCHMIDT, KH
    PATTERN RECOGNITION LETTERS, 1988, 8 (02) : 73 - 85
  • [33] RESPIRATORY GATING OF MAGNETIC-RESONANCE IMAGES
    CLANTON, JA
    RUNGE, VM
    JAMES, AE
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (05) : P7 - P7
  • [34] SEGMENTATION OF MAGNETIC-RESONANCE BRAIN IMAGES
    KOHN, MI
    NCGA 89 CONFERENCE PROCEEDINGS, VOLS 1-3, 1989, : A168 - A171
  • [35] TECHNICAL BASIS FOR MAGNETIC-RESONANCE IMAGES
    PASSERINI, A
    STRADA, L
    GRISOLI, M
    SBERNA, M
    BRUZZONE, MG
    CHILDS NERVOUS SYSTEM, 1990, 6 (01) : 33 - 36
  • [36] NUCLEAR MAGNETIC-RESONANCE CHEMICAL-SHIFTS USING OPTIMIZED GEOMETRIES
    CHESNUT, DB
    PHUNG, CG
    JOURNAL OF CHEMICAL PHYSICS, 1989, 91 (10): : 6238 - 6245
  • [37] DIAGNOSTIC APPLICATIONS OF NUCLEAR MAGNETIC-RESONANCE
    LETERRIER, F
    GRANIER, R
    MEDECINE ET ARMEES, 1979, 7 (07): : 607 - 613
  • [38] NOISE-REDUCTION FOR T2 DERIVED MAGNETIC-RESONANCE IMAGES
    BUHLE, EL
    BLOCH, P
    LENKINSKI, RE
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1990, 14 (03) : 185 - 190
  • [39] Suppression of vascular artifacts in functional magnetic resonance images using MR angiograms
    Hlustik, P
    Noll, DC
    Small, SL
    NEUROIMAGE, 1998, 7 (03) : 224 - 231
  • [40] THE DIAGNOSTIC-VALUE OF RENAL CORTEX-TO-MEDULLA CONTRAST ON MAGNETIC-RESONANCE IMAGES
    TERRIER, F
    HRICAK, H
    JUSTICH, E
    DOOMS, GC
    GRODD, W
    EUROPEAN JOURNAL OF RADIOLOGY, 1986, 6 (02) : 121 - 126