An Ultrasound Study of Cerebral Venous Drainage after Internal Jugular Vein Catheterization

被引:10
|
作者
Vailati, Davide [1 ]
Lamperti, Massimo [1 ]
Subert, Matteo [1 ]
Sommariva, Alberto [1 ]
机构
[1] Neurol Inst C Besta, Dept Neuroanesthesia, I-20133 Milan, Italy
关键词
D O I
10.1155/2012/685481
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives. it has been advocated that internal jugular vein (IJV) cannulation in patients at risk for intracranial hypertension could impair cerebral venous return. Aim of this study was to demonstrate that ultrasound-guided IJV cannulation in elective neurosurgical patients is safe and does not impair cerebral venous return. Methods. IJV cross-sectional diameter and flow weremeasured using two-dimensional ultrasound and Doppler function bilaterally before and after IJV cannulation with the head supine and elevated at 30 degrees. Results. Fifty patients with intracranial lesions at risk for intracranial hypertension were enrolled in this observational prospective study. IJV diameters before and after ultrasound-guided cannulation were not statistically different during supine or head-up position and the absolute variation of the venous flow revealed an average reduction of the venous flow after cannulation without a significant reduction of the venous flow rate after cannulation. Conclusions. Ultrasound-guided IJV cannulation in neurosurgical patients at risk for intracranial hypertension does not impair significantly jugular venous flow and indirectly cerebral venous return.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Internal jugular versus subclavian vein catheterization for central venous catheterization in orthotopic liver transplantation
    Torgay, A
    Pirat, A
    Candan, S
    Zeyneloglu, P
    Arslan, G
    Haberal, M
    TRANSPLANTATION PROCEEDINGS, 2005, 37 (07) : 3171 - 3173
  • [32] Internal jugular vein and intracranial venous drainage in transient global amnesia
    Valdueza, J. M.
    CEREBROVASCULAR DISEASES, 2014, 37 : 28 - 28
  • [33] A POINT OF CARE ULTRASOUND DURING CATHETERIZATION OF INTERNAL JUGULAR VEIN; SONOGRAPHIC ASSESSMENT OF THE VENOUS EXCAVATION (SAVE) PROTOCOL
    Park, S-M
    Kim, H.
    Doh, H.
    Koh, C-Y
    INTENSIVE CARE MEDICINE, 2014, 40 : S204 - S204
  • [34] Ultrasound-facilitated versus anatomically oriented biopsy of the internal jugular vein for central venous catheterization -: Reply
    Förster, R
    ULTRASCHALL IN DER MEDIZIN, 1999, 20 (06): : 274 - 274
  • [35] The surface projection line of internal jugular vein to guide the internal jugular vein catheterization
    Yu, Qing-Qing
    Ren, Qiu-Sheng
    Liang, Rui-Jia
    VASCULAR, 2019, 27 (05) : 535 - 536
  • [36] SONOGRAPHIC DETECTION OF INTERNAL JUGULAR-VEIN THROMBOSIS AFTER CENTRAL VENOUS CATHETERIZATION IN THE NEWBORN PERIOD
    RAND, T
    KOHLHAUSER, C
    POPOW, C
    ROKITANSKY, A
    KAINBERGER, F
    JAKL, RJ
    PONHOLD, W
    WENINGER, M
    PEDIATRIC RADIOLOGY, 1994, 24 (08) : 577 - 580
  • [37] The accuracy of the central landmark used for central venous catheterization of the internal jugular vein
    Bailey, PL
    Whitaker, EE
    Palmer, LS
    Glance, LG
    ANESTHESIA AND ANALGESIA, 2006, 102 (05): : 1327 - 1332
  • [38] Internal Jugular Vein Valve Dysfunction and Venous Dissection-Complications of Central Venous Catheterization
    Ogawa, Miho
    Honda, Jun
    Yoshida, Keisuke
    Yakushiji, Tatsumi
    Inoue, Satoki
    ANNALS OF CARDIAC ANAESTHESIA, 2024, 27 (04) : 383 - 384
  • [39] CEREBRAL VENOUS INFARCTION SECONDARY TO OTOGENIC INTERNAL JUGULAR VEIN AND CEREBRAL VENOUS SINUSES THROMBOSIS
    Espada Rubio, S.
    Cantador Pavon, E.
    Lopez Carbonero, J. I.
    Lopez Diego, V.
    Castellano Vicente, A.
    Martinez Lopez, E.
    Novillo Lopez, M. E.
    INTERNATIONAL JOURNAL OF STROKE, 2020, 15 (1_SUPPL) : 717 - 717
  • [40] Routine Chest Radiography Is Not Necessary After Ultrasound-Guided Right Internal Jugular Vein Catheterization
    Hourmozdi, Justin J.
    Markin, Abraham
    Johnson, Brad
    Fleming, Patrick R.
    Miller, Joseph B.
    CRITICAL CARE MEDICINE, 2016, 44 (09) : E804 - E808