EXPEDIENT SET-UP OF TANGENTIAL BREAST FIELDS WITH A SIMPLE GANTRY ATTACHMENT

被引:0
|
作者
BREZOVICH, IA
MEREDITH, RF
WEPPELMANN, B
PAREEK, PN
SALTER, MM
机构
[1] Department of Radiation Oncology, University of Alabama at Birmingham, Birmingham, AL 35233
关键词
BREAST CANCER; SET-UP TECHNIQUES; TANGENTIAL FIELDS;
D O I
10.1016/0360-3016(91)90752-P
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A novel technique for setting up tangential fields is described. The technique uses a simple device (Breast Aligner) which attaches to the collimator of the treatment unit. The function of the Breast Aligner is similar to conventional front and back pointers except that the beam edge rather than central ray is defined. By delineating beam entrance and exit points at the posterior field edge, the device greatly simplifies and expedites set-up, and enhances precision of port alignment. Additional advantageous features include: (a) the ability to compensate for small inadvertent variations from the initial set-up position or for patient movement between the set-up of opposing ports, (b) the ability to visually check port alignment in the treatment position immediately before irradiation, and (c) decreased chance of human and equipment error by eliminating the need for measurements and calculations at the time of treatment. Our method can be used for SSD or SAD techniques and, with minor adjustment, is applicable for establishment of coplanar cephalad field borders as required at the junction of a supraclavicular field.
引用
收藏
页码:1073 / 1083
页数:11
相关论文
共 50 条
  • [31] Tattoo Free Set-up for Partial Breast Irradiation: A Feasibility Study
    Jimenez, R. B.
    Batin, E.
    Giantsoudi, D.
    Hazeltine, W.
    Bertolino, K.
    MacDonald, S.
    Taghian, A. G.
    Gierga, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E600 - E600
  • [32] Dosimetric Validation of Surface Guided Patient Set-Up for Breast Radiotherapy
    Gopal, A.
    Lasio, G.
    Zhang, B.
    Xu, H.
    Chen, S.
    Mcavoy, S.
    Decesaris, C.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [33] A simple, low-cost and fast Peltier thermoregulation set-up for electrophysiology
    Corrèges, P
    Bugnard, E
    Millerin, C
    Masiero, A
    Andrivet, JP
    Bloc, A
    Dunant, Y
    JOURNAL OF NEUROSCIENCE METHODS, 1998, 83 (02) : 177 - 184
  • [34] SIMPLE AND VERY SENSITIVE SET-UP FOR SUPERCONDUCTIVITY MAGNETIZATION MEASUREMENTS ON TUBULAR SAMPLES
    CIMBERLE, MR
    FERDEGHINI, C
    SIRI, AS
    CRYOGENICS, 1989, 29 (01) : 69 - 70
  • [35] Simple schemes for traffic integration at call set-up level in ATM networks
    Univ of Genoa, Genova, Italy
    Comput Commun, 8 (645-652):
  • [36] SIMPLE HAND-EYE EXPERIMENTAL SET-UP FOR COMPUTER VISION RESEARCH
    JARVIS, RA
    COMPUTER, 1977, 10 (09) : 65 - 69
  • [37] Simple schemes for traffic integration at call set-up level in ATM networks
    Bolla, R
    Davoli, F
    Marchese, M
    COMPUTER COMMUNICATIONS, 1996, 19 (08) : 645 - 652
  • [38] A simple set-up for the evaluation of air-sensitive magnetic powders and composites
    Tournilhac, FG
    Garde, R
    Verdaguer, M
    INORGANICA CHIMICA ACTA, 2001, 326 (01) : 73 - 77
  • [39] SIMPLE AND RELATIVELY EXACT METHOD TO GENERATE TUNING FREQUENCY OF A LEVEL SET-UP
    HARZER, P
    NACHRICHTENTECHNISCHE ZEITSCHRIFT, 1971, 24 (10): : 545 - &
  • [40] A simple and convenient set-up for high-temperature Brillouin light scattering
    Guerette, Michael
    Huang, Liping
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2012, 45 (27)