PLASMA DIAGNOSTIC-X-RAY TOMOGRAPHY SYSTEM

被引:0
|
作者
ESHELMAN, CD
TSENG, HK
DOLAN, TJ
PRELAS, MA
机构
[1] UNIV MISSOURI,DEPT NUCL ENGN,ROLLA,MO 65401
[2] UNIV MISSOURI,DEPT NUCL ENGN,COLUMBIA,MO 65211
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1991年 / 62卷 / 03期
关键词
D O I
10.1063/1.1142079
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A radiation-hardened 60-channel x-ray tomography system has been developed to determine the two-dimensional distribution of x-ray emissivity from magnetically confined plasmas. In order to maximize their field of view, the diode arrays are mounted in re-entrant tubes inside the plasma chamber diagnostic ports. Metal foil vacuum windows serve as x-ray filters and permit the diodes and cables to be at atmospheric pressure. Preamplifers are mounted at the outside end of the re-entrant tubes. The diode arrays and preamplifiers are protected from the harsh radiation environment by lead shielding. Image reconstruction is done using the harmonic expansion method or the linear algebraic method. For plasmas with some cylindrical symmetry the harmonic expansion method is superior, but for small discrete objects the Cartesian algebraic method is better. Preliminary data from the Missouri Magnetic Mirror plasma with electron cyclotron resonance heating show evidence of a hot electron ring.
引用
收藏
页码:751 / 754
页数:4
相关论文
共 50 条
  • [21] ATTENUATION PROPERTIES OF DIAGNOSTIC-X-RAY SHIELDING MATERIALS
    ARCHER, BR
    FEWELL, TR
    CONWAY, BJ
    QUINN, PW
    MEDICAL PHYSICS, 1994, 21 (09) : 1499 - 1507
  • [22] THE MEASUREMENT OF TOTAL FILTRATION OF DIAGNOSTIC-X-RAY TUBES
    CRANLEY, K
    FOGARTY, GWA
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (725): : 388 - 392
  • [23] THE POSITION OF THE PERSONAL DOSIMETER IN DIAGNOSTIC-X-RAY PRACTICE
    BUCHAN, RCT
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (715): : 728 - 728
  • [24] ANNUAL FREQUENCY OF DIAGNOSTIC-X-RAY EXAMINATIONS IN THE NETHERLANDS
    BEENTJES, LB
    TIMMERMANS, CW
    HEALTH PHYSICS, 1990, 59 (03): : 357 - 358
  • [25] PRACTICAL BEAM FILTERS FOR DIAGNOSTIC-X-RAY MACHINES
    SIEDBAND, MP
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 772 - 772
  • [26] MORE ON GENERATOR LINEARITY OF DIAGNOSTIC-X-RAY EQUIPMENT
    RUMMERFIELD, PS
    HEALTH PHYSICS, 1983, 45 (03): : 815 - 816
  • [27] RECONSTRUCTION OF DIAGNOSTIC-X-RAY SPECTRA BY ATTENUATION ANALYSIS
    HUANG, PH
    KASE, KR
    MEDICAL PHYSICS, 1983, 10 (04) : 546 - 547
  • [28] EFFECT OF COLLIMATORS ON THE MEASUREMENT OF DIAGNOSTIC-X-RAY SPECTRA
    KODERA, Y
    CHAN, HP
    DOI, K
    PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (07): : 841 - 852
  • [29] TRANSMISSION DATA FOR SHIELDING DIAGNOSTIC-X-RAY FACILITIES
    SIMPKIN, DJ
    HEALTH PHYSICS, 1995, 68 (05): : 704 - 709
  • [30] LAPLACE RECONSTRUCTION OF EXPERIMENTAL DIAGNOSTIC-X-RAY SPECTRA
    ARCHER, BR
    FEWELL, TR
    WAGNER, LK
    MEDICAL PHYSICS, 1988, 15 (06) : 832 - 837