ZIRCONIUM ISOTOPE SHIFT MEASUREMENT USING LASER PUMPING AND OPTOGALVANIC DETECTION

被引:4
|
作者
LANGLOIS, E
GAGNE, JM
机构
[1] Laboratoire d’ Optique et de Spectroscopie, Département de Génie Physique, Ecole Polytechnique de Monétral Campus de J’Université de Montréal, Montréal
关键词
D O I
10.1364/JOSAB.11.000552
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report the measurement of the even isotope shifts for eight zirconium transitions between odd levels near 18 000 cm-1 and levels of the e5F even term located above 35 000 cm-1. These transitions are scanned by a probe dye laser; the optogalvanic effect is used to detect laser absorption, while laser pumping from the ground term is employed to increase the population of the odd levels in the hollow-cathode lamp used as the zirconium vapor generator. Because of the narrow bandwidth (5 MHz) of the pump beam, for each isotope only atoms in a specific speed class are pumped, and the probe beam requires no other sub-Doppler techniques for the different zirconium isotopes to be resolved.
引用
收藏
页码:552 / 557
页数:6
相关论文
共 50 条
  • [21] Comparative Study of Electric Field Measurement in Glow Discharges using Laser Optogalvanic Spectroscopy
    Hussain, Shahid
    Saleem, M.
    Baig, M. A.
    SPECTRAL LINE SHAPES VOL 15, 2008, 1058 : 169 - +
  • [22] MEASUREMENT OF ABSORPTION LINE PROFILE BY LASER OPTOGALVANIC SPECTROSCOPY.
    Kalinov, V.S.
    Ovseichuk, S.I.
    1600, (47):
  • [23] Laser optogalvanic spectroscopy of lead lines - Isotope shifts and hyperfine structure studies
    Sobolewski, L. M.
    Rathi, S.
    Sharma, L.
    Windholz, L.
    Kwela, J.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2024, 316
  • [24] LASER MEASUREMENT OF THE O-16-O-18 ISOTOPE SHIFT AT OPTICAL FREQUENCIES
    ERNST, K
    MINUTOLO, P
    SASSO, A
    TINO, GM
    INGUSCIO, M
    OPTICS LETTERS, 1989, 14 (11) : 554 - 556
  • [25] Optogalvanic detection of velocity-selective optical pumping in an open, cascade atomic medium
    de Araujo, Luis E. E.
    Carvalho, Silvania A.
    Cruz, Luciano S.
    Soares, A. A.
    Mirage, Armando
    Pereira, Daniel
    Cruz, Flavio C.
    OPTICS COMMUNICATIONS, 2008, 281 (04) : 626 - 632
  • [26] OPTOGALVANIC MEASUREMENT OF ISOTOPE SHIFTS OF DOUBLY IONIZED URANIUM (U III) MADE USING NATURAL-U SAMPLES
    PIYAKIS, KN
    GAGNE, JM
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1989, 6 (12) : 2289 - 2294
  • [27] Determination of actinide isotope ratios using glow discharge optogalvanic spectroscopy
    Young, JP
    Shaw, RW
    Barshick, CM
    Ramsey, JM
    JOURNAL OF ALLOYS AND COMPOUNDS, 1998, 271 : 62 - 65
  • [28] Measurement of hyperfine structure and isotope shift of transitions in gadolinium using blue diode
    Niki, H
    Tanikawa, T
    Tokita, S
    Izawa, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (08): : 6075 - 6078
  • [29] Isotope shift measurement at 244fAm
    Backe, H
    Dretzke, A
    Hies, M
    Kube, G
    Kunz, H
    Lauth, W
    Sewtz, M
    Trautmann, N
    Repnow, R
    Maier, HJ
    HYPERFINE INTERACTIONS, 2000, 127 (1-4): : 35 - 39
  • [30] Isotope shift measurement at 244fAm *
    H. Backe
    A. Dretzke
    M. Hies
    G. Kube
    H. Kunz
    W. Lauth
    M. Sewtz
    N. Trautmann
    R. Repnow
    H.J. Maier
    Hyperfine Interactions, 2000, 127 : 35 - 39