A CONTROL-LOOP PERFORMANCE MONITOR

被引:196
|
作者
HAGGLUND, T
机构
[1] Department of Automatic Control, Lund Institute of Technology
关键词
VALVE; OSCILLATION; FRICTION; STICK-SLIP MOTION; FAULT DETECTION;
D O I
10.1016/0967-0661(95)00164-P
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A procedure for automatic monitoring of control-loop performance is presented. The control-loop performance monitor (CLPM) detects oscillations in the control loop. These oscillations are normally caused by too-high friction in the control valve, but there are other reasons as well. The CLPM is primarily intended to be connected to PID controllers, but it can also be connected to other controllers. The procedure is automatic in the sense that no additional parameters except the normal controller parameters have to be specified. The paper contains both a derivation of the CLPM and results from industrial experiments.
引用
收藏
页码:1543 / 1551
页数:9
相关论文
共 50 条
  • [31] Shot-noise-limited control-loop noise in an interferometer with multiple degrees of freedom
    Somiya, Kentaro
    Miyakawa, Osamu
    APPLIED OPTICS, 2010, 49 (23) : 4335 - 4342
  • [32] PWM-PD multiple output DC/DC converters:: Operation and control-loop modeling
    Barrado, A
    Olías, E
    Lázaro, A
    Pleite, J
    Vázquez, R
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2004, 19 (01) : 140 - 149
  • [33] Control-loop modeling of the controllable ZVS PWM forward converters using saturable magnetic cores
    Chen, YT
    Liu, WH
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (01) : 140 - 155
  • [34] Hydrogenerator control-loop monitoring using graphical results obtained from a principal component analysis
    Cyr, C
    Poulin, É
    Pomerleau, A
    Desbiens, A
    IEE PROCEEDINGS-CONTROL THEORY AND APPLICATIONS, 2006, 153 (01): : 53 - 58
  • [35] A derivation of the long-term degradation of a pulsed atomic frequency standard from a control-loop model
    Greenhall, CA
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (04) : 895 - 898
  • [36] Control-loop interaction in multi-output DC-DC converter with magamp post-regulation
    Wang, Jian-Hua
    Qian, Zhu-Xu
    Zhang, Fang-Hua
    Gong, Chun-Ying
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (09): : 33 - 39
  • [37] A NOC closed-loop performance monitor and adapter
    Matos, Debora
    Concatto, Caroline
    Kologeski, Anelise
    Carro, Luigi
    Kreutz, Marcio
    Kastensmidt, Fernanda
    Susin, Altamiro
    MICROPROCESSORS AND MICROSYSTEMS, 2013, 37 (6-7) : 661 - 671
  • [38] Extending the admissible control-loop delays for the inverted pendulum by fractional-order proportional-derivative controller
    Balogh, Tamas
    Insperger, Tamas
    JOURNAL OF VIBRATION AND CONTROL, 2024, 30 (11-12) : 2596 - 2604
  • [39] HIGH-SPEED MONITOR FOR CLOSED-LOOP CONTROL
    LENNOX, CG
    PEARSON, A
    NUCLEONICS, 1962, 20 (06): : 73 - &
  • [40] Assessing control loop performance
    VanDoren, VJ
    CONTROL ENGINEERING, 1999, 46 (05) : 91 - +