Stent graft placement and balloon dilation for pseudoaneurysm complicated by distal arterial stenosis of the hepatic artery after pancreaticoduodenectomy

被引:0
|
作者
Fujioka, Shuichi [1 ]
Suzuki, Fumitake [1 ]
Funamizu, Naotake [1 ]
Okamoto, Tomoyoshi [1 ]
Munakata, Koji [2 ]
Ashida, Hirokazu [2 ]
Yanaga, Katsuhiko [3 ]
机构
[1] Jikei Univ, Daisan Hosp, Dept Surg, 4-11-1,Izumi Honcho, Komae, Tokyo 2010003, Japan
[2] Jikei Daisan Hosp, Dept Radiol, Tokyo 2010003, Japan
[3] Jikei Univ, Sch Med, Dept Surg, Tokyo 1058461, Japan
来源
SURGICAL CASE REPORTS | 2015年 / 1卷
关键词
Pseudoaneurysm; Interventional radiology; Stent graft; Balloon dilation;
D O I
10.1186/s40792-015-0060-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Hemorrhage from ruptured pseudoaneurysm is a rapidly progressing and potentially fatal complication after pancreaticoduodenectomy (PD). Stent graft placement for hepatic artery pseudoaneurysm has recently been reported as a valid alternative to transcatheter arterial embolization (TAE). We report a case of pseudoaneurysm of the common hepatic artery (CHA) with distal arterial stenosis treated by stent graft placement for pseudoaneurysm and balloon dilation for arterial stenosis due to pancreatic fistula after PD. A 67-year-old man underwent PD for intraductal papillary mucinous neoplasm with concomitant early gastric cancer. After the operation, pancreatic fistula developed, for which conservative management by drainage was continued. On the postoperative day 30, melena started. Emergency abdominal angiography revealed a pseudoaneurysm in the CHA, as well as distal arterial stenosis extending from the proper hepatic artery (PHA) to bilateral hepatic arteries. The portal vein was also stenotic due to pancreatic fistula, for which TAE was not judged suitable because of the risk of liver failure. Therefore, stent graft placement and balloon dilation were chosen. Three pieces of coronary covered stent were placed in a coaxial overlapping manner followed by balloon dilation of the proper and left hepatic arteries. Balloon dilation of the right hepatic artery failed by technical reasons. Completion arteriography confirmed the patency from the CHA to the left hepatic artery as well as the exclusion of the pseudoaneurysm. A liver abscess that developed in the right hepatic lobe after intervention was successfully treated by percutaneous drainage, and the patient discharged on day 27 after stent graft placement. Non-embolic management with preservation of the liver arterial flow may be an option for complicated pseudoaneurysm after PD.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Superior mesenteric artery pseudoaneurysm following pancreaticoduodenectomy: Management by endovascular stent-graft placement and transluminal thrombin injection
    Wallace, Michael J.
    Choi, Eugene
    McRae, Stephen
    Madoff, David C.
    Ahrar, Kamran
    Pisters, Peter
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (03) : 518 - 522
  • [22] Stent-graft placement for femoral artery pseudoaneurysm in a patient with idiopathic multiple arterial aneurysmal disease
    Koo, BK
    Choi, D
    Kwon, K
    Jang, Y
    Shim, WH
    Cho, SY
    Lee, DY
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 25 (06) : 520 - 523
  • [23] Stent-Graft Placement for Femoral Artery Pseudoaneurysm in a Patient with Idiopathic Multiple Arterial Aneurysmal Disease
    Bon Kwon Koo
    Donghoon Choi
    Kihwan Kwon
    Yangsoo Jang
    Won-Heum Shim
    Seung-Yun Cho
    Do Yun Lee
    CardioVascular and Interventional Radiology, 2002, 25 : 520 - 523
  • [24] Superior Mesenteric Artery Pseudoaneurysm Following Pancreaticoduodenectomy: Management by Endovascular Stent-Graft Placement and Transluminal Thrombin Injection
    Michael J. Wallace
    Eugene Choi
    Stephen McRae
    David C. Madoff
    Kamran Ahrar
    Peter Pisters
    CardioVascular and Interventional Radiology, 2007, 30 : 518 - 522
  • [25] Percutaneous Transarterial Stent Placement in a Transplant Liver Hepatic Artery Complicated by Angioplasty Balloon Rupture and Fragmentation
    Vairavamurthy, Jenanan P.
    Li, Charles
    Urban, Seth
    Katz, Michael
    SEMINARS IN INTERVENTIONAL RADIOLOGY, 2019, 36 (02) : 133 - 136
  • [26] Covered Stent Placement Using "Pull-Through" Technique for a Gastroduodenal Artery Stump Pseudoaneurysm after Pancreaticoduodenectomy
    Miyazawa, Ryo
    Kamo, Minobu
    Nishiyama, Tomoya
    Ohigashi, Seiji
    Yagihashi, Kunihiro
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (11) : 1743 - 1745
  • [27] Hemobilia Due to Hepatic Artery Pseudoaneurysm Secondary to Biliary Stent Placement
    Nasir, Umair M.
    Parikh, Aashka
    Paer, Jeffrey M.
    Surathi, Pratibha
    Yu, Qi
    Pergament, Kathleen
    Ahlawat, Sushil
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2020, 115 : S784 - S785
  • [28] Right Hepatic Artery Pseudoaneurysm: A Rare Complication of Biliary Stent Placement
    Guerson-Gil, Arcelia Marlane
    Patel, Param
    Ho, Sammy
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2021, 116 : S1076 - S1076
  • [29] Stent Graft of Pseudoaneurysm Rupture After Subtotal Stomach-preserving Pancreaticoduodenectomy
    Kimura, Koichi
    Minagawa, Ryosuke
    Yamaoka, Terutoshi
    Izumi, Takuma
    Takahashi, Yu
    Nakanishi, Mitsuru
    Tokunaga, Takayuki
    Matsuda, Daisuke
    Honma, Kenichi
    Nagata, Shigeyuki
    Minami, Kazuhito
    Nishizaki, Takashi
    ANTICANCER RESEARCH, 2023, 43 (08) : 3639 - 3645
  • [30] Stent placement in pediatric patients with hepatic artery stenosis or thrombosis after liver transplantation
    Boyvat, F.
    Aytekin, C.
    Karakayali, H.
    Ozyer, U.
    Sevmis, S.
    Emiroglu, R.
    Haberal, M.
    TRANSPLANTATION PROCEEDINGS, 2006, 38 (10) : 3656 - 3660