Stent graft placement and balloon dilation for pseudoaneurysm complicated by distal arterial stenosis of the hepatic artery after pancreaticoduodenectomy

被引:0
|
作者
Fujioka, Shuichi [1 ]
Suzuki, Fumitake [1 ]
Funamizu, Naotake [1 ]
Okamoto, Tomoyoshi [1 ]
Munakata, Koji [2 ]
Ashida, Hirokazu [2 ]
Yanaga, Katsuhiko [3 ]
机构
[1] Jikei Univ, Daisan Hosp, Dept Surg, 4-11-1,Izumi Honcho, Komae, Tokyo 2010003, Japan
[2] Jikei Daisan Hosp, Dept Radiol, Tokyo 2010003, Japan
[3] Jikei Univ, Sch Med, Dept Surg, Tokyo 1058461, Japan
来源
SURGICAL CASE REPORTS | 2015年 / 1卷
关键词
Pseudoaneurysm; Interventional radiology; Stent graft; Balloon dilation;
D O I
10.1186/s40792-015-0060-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Hemorrhage from ruptured pseudoaneurysm is a rapidly progressing and potentially fatal complication after pancreaticoduodenectomy (PD). Stent graft placement for hepatic artery pseudoaneurysm has recently been reported as a valid alternative to transcatheter arterial embolization (TAE). We report a case of pseudoaneurysm of the common hepatic artery (CHA) with distal arterial stenosis treated by stent graft placement for pseudoaneurysm and balloon dilation for arterial stenosis due to pancreatic fistula after PD. A 67-year-old man underwent PD for intraductal papillary mucinous neoplasm with concomitant early gastric cancer. After the operation, pancreatic fistula developed, for which conservative management by drainage was continued. On the postoperative day 30, melena started. Emergency abdominal angiography revealed a pseudoaneurysm in the CHA, as well as distal arterial stenosis extending from the proper hepatic artery (PHA) to bilateral hepatic arteries. The portal vein was also stenotic due to pancreatic fistula, for which TAE was not judged suitable because of the risk of liver failure. Therefore, stent graft placement and balloon dilation were chosen. Three pieces of coronary covered stent were placed in a coaxial overlapping manner followed by balloon dilation of the proper and left hepatic arteries. Balloon dilation of the right hepatic artery failed by technical reasons. Completion arteriography confirmed the patency from the CHA to the left hepatic artery as well as the exclusion of the pseudoaneurysm. A liver abscess that developed in the right hepatic lobe after intervention was successfully treated by percutaneous drainage, and the patient discharged on day 27 after stent graft placement. Non-embolic management with preservation of the liver arterial flow may be an option for complicated pseudoaneurysm after PD.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Stent graft placement and balloon dilation for pseudoaneurysm complicated by distal arterial stenosis of the hepatic artery after pancreaticoduodenectomy
    Shuichi Fujioka
    Fumitake Suzuki
    Naotake Funamizu
    Tomoyoshi Okamoto
    Koji Munakata
    Hirokazu Ashida
    Katsuhiko Yanaga
    Surgical Case Reports, 1 (1)
  • [2] Use of a stent graft for bleeding hepatic artery pseudoaneurysm following pancreaticoduodenectomy
    Kaw, Leoncio L., Jr.
    Saeed, Moshin
    Brunson, Matt
    Delaria, Giacomo A.
    Dilley, Ralph B.
    ASIAN JOURNAL OF SURGERY, 2006, 29 (04) : 283 - 286
  • [3] Treatment of post-liver transplant hepatic artery pseudoaneurysm with balloon angioplasty after failed stent graft placement
    Lu, Ning-Ning
    Huang, Qiang
    Wang, Jian-Feng
    Wei, Bao-Jie
    Gao, Kun
    Zhai, Ren-You
    CLINICS AND RESEARCH IN HEPATOLOGY AND GASTROENTEROLOGY, 2012, 36 (06) : E109 - E113
  • [4] Successful treatment of an iatrogenic right hepatic artery pseudoaneurysm and stenosis with a stent graft
    Hylton, Jared R.
    Pevec, William C.
    JOURNAL OF VASCULAR SURGERY, 2010, 51 (06) : 1510 - 1513
  • [5] Covered stent placement for hepatic artery pseudoaneurysm
    Li Cui
    Lu Kong
    Yan-Hua Bai
    Xiao-Hui Li
    Xiu-Qi Wang
    Jing-jing Hao
    Feng Duan
    Abdominal Radiology, 2020, 45 : 3337 - 3341
  • [6] Covered stent placement for hepatic artery pseudoaneurysm
    Cui, Li
    Kong, Lu
    Bai, Yan-Hua
    Li, Xiao-Hui
    Wang, Xiu-Qi
    Hao, Jing-jing
    Duan, Feng
    ABDOMINAL RADIOLOGY, 2020, 45 (10) : 3337 - 3341
  • [7] Stent-Graft Placement for Management of Iatrogenic Hepatic Artery Branch Pseudoaneurysm After Liver Transplantation
    Ginat, Daniel T.
    Saad, Wael E. A.
    Waldman, David L.
    Davies, Mark G.
    VASCULAR AND ENDOVASCULAR SURGERY, 2009, 43 (05) : 513 - 517
  • [8] Metallic stent placement in hemodialysis graft patients after insufficient balloon dilation
    Liang, Huei-Lung
    Pan, Huay-Ben
    Lin, Yih-Huie
    Chen, Chiung-Yu
    Chung, Hsiao-Min
    Wu, Tung-Ho
    Chou, Kang-Ju
    Lai, Pin-Hong
    Yang, Chien-Fang
    KOREAN JOURNAL OF RADIOLOGY, 2006, 7 (02) : 118 - 124
  • [9] Stent-Graft Treatment for Bleeding Superior Mesenteric Artery Pseudoaneurysm After Pancreaticoduodenectomy
    Suzuki, Kojiro
    Mori, Yoshine
    Komada, Tomohiro
    Matsushima, Masaya
    Ota, Toyohiro
    Naganawa, Shinji
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (04) : 762 - 766
  • [10] Stent-Graft Treatment for Bleeding Superior Mesenteric Artery Pseudoaneurysm After Pancreaticoduodenectomy
    Kojiro Suzuki
    Yoshine Mori
    Tomohiro Komada
    Masaya Matsushima
    Toyohiro Ota
    Shinji Naganawa
    CardioVascular and Interventional Radiology, 2009, 32 : 762 - 766