Bilateral Three-Level Lumbar Spondylolysis Repaired by Hook-Screw Technique

被引:4
|
作者
Sharifi, Guive [1 ]
Jahanbakhshi, Amin [1 ]
Daneshpajouh, Behnam [1 ]
Rahimizadeh, Abolfazl [2 ]
机构
[1] Shahid Beheshti Univ Med Sci, Loghman Hakim Med Ctr, Dept Neurosurg, Tehran, Iran
[2] Iranian Neurospine Assoc, Tehran, Iran
关键词
hook-screw; low back pain; spondylolysis;
D O I
10.1055/s-0032-1307255
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We report a case of bilateral three-level lumbar spondylolysis that was directly repaired by use of hook-screw technique. The patient complained of low back pain for 2 years that progressively worsened and was exacerbated with standing and walking. He also mentioned bilateral sciatalgia. The neurological examination was normal. Interestingly, we found bilateral lumbar spondylolysis in L3, L4, and L5 levels in imaging studies. After proving that spondylolysis was the source of the low back pain by local anesthetic agent injection, we used a direct technique for correction of spondylolysis by use of a hookscrew device plus decortications of lysis area and iliac crest autograft. We assessed the patient after surgery to evaluate pain recovery and fusion rate. The results were favorable and proved the efficacy of the hook-screw technique for treatment of symptomatic multilevel lumbar spondylolysis.
引用
收藏
页码:51 / 55
页数:5
相关论文
共 50 条
  • [1] REPAIR OF LUMBAR SPONDYLOLYSIS WITH A HOOK-SCREW
    HEFTI, F
    SEELIG, W
    MORSCHER, E
    INTERNATIONAL ORTHOPAEDICS, 1992, 16 (01) : 81 - 85
  • [2] Minimally invasive direct repair of lumbar spondylolysis with a pedicle screw and hook construct
    Noggle, Joseph C.
    Sciubba, Daniel M.
    Samdani, Amer F.
    Anderson, D. Greg
    Betz, Randal R.
    Asghar, Jahangir
    NEUROSURGICAL FOCUS, 2008, 25 (02)
  • [3] Biomechanical and clinical study on screw hook fixation after direct repair of lumbar spondylolysis
    赵剑
    刘璠
    施红光
    樊建
    赵卫东
    王友华
    蔡玉辉
    中华创伤杂志(英文版), 2006, (05) : 288 - 292
  • [4] Biomechanical and clinical study on screw hook fixation after direct repair of lumbar spondylolysis
    赵剑
    刘璠
    施红光
    樊建
    赵卫东
    王友华
    蔡玉辉
    Chinese Journal of Traumatology, 2006, (05) : 288 - 292
  • [5] Biomechanical analysis of a novel hook-screw technique for C1-2 stabilization Technical note
    Reis, Marco Tulio
    Nottmeier, Eric W.
    Reyes, Phillip M.
    Baek, Seungwon
    Crawford, Neil R.
    JOURNAL OF NEUROSURGERY-SPINE, 2012, 17 (03) : 220 - 226
  • [6] Screw-type transparency in a three-level medium
    Kazinets, IV
    Matisov, BG
    Mazets, IE
    JETP LETTERS, 1998, 67 (11) : 919 - 926
  • [7] Screw-type transparency in a three-level medium
    I. V. Kazinets
    B. G. Matisov
    I. E. Mazets
    JETP Letters, 1998, 67
  • [8] Application of a new anatomic hook-rod-pedicle screw system in young patients with lumbar spondylolysis: A pilot study
    Li, Duan-Ming
    Li, Yong-Chao
    Jiang, Wei
    Peng, Bao-Gan
    WORLD JOURNAL OF CLINICAL CASES, 2022, 10 (17) : 5680 - 5689
  • [9] Application of a new anatomic hook-rod-pedicle screw system in young patients with lumbar spondylolysis:A pilot study
    Duan-Ming Li
    Yong-Chao Li
    Wei Jiang
    Bao-Gan Peng
    World Journal of Clinical Cases, 2022, (17) : 5680 - 5689
  • [10] Buck technique supplemented by temporary intersegmental pedicle screw fixation to repair lumbar spondylolysis in youth
    Ye, Yuchen
    Yang, Huiwen
    Ma, Tao
    Zhu, Kun
    Xu, Gang
    Han, Zhongbing
    Zhang, Zhili
    Wu, Nan
    Guo, Xuan
    Li, Huanyu
    Zhou, Pinghui
    Bao, Zhengqi
    Zhang, Changchun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):