INTRAPELVIC 2-DIMENSIONAL TIME-OF-FLIGHT MAGNETIC-RESONANCE ANGIOGRAPHY IN HEALTHY AND DISEASED SUBJECTS

被引:10
|
作者
YOSHIKAWA, K
SUGIMURA, K
KAWAMITSU, H
ISHIDA, T
机构
[1] Department of Radiology, Shimane Medical University
来源
BRITISH JOURNAL OF RADIOLOGY | 1994年 / 67卷 / 794期
关键词
D O I
10.1259/0007-1285-67-794-140
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We evaluated the use of magnetic resonance angiography (MRA) based on two-dimensional (2D) time-of-flight (TOF) technique in the pelvic vasculature. In the initial phase of this study, MRA was performed in 10 normal subjects for determination of the optimum imaging parameters. Systemically varied scan parameters included flip angle ranging from 20 degrees to 90 degrees by 10 degrees increments and repetition time (TR) of 30, 40, and 50 ms. The optimum imaging parameters for intrapelvic MR angiography were found to be flip angle of 90 degrees, pulse sequence of 30/4.9 (TR ms/TE ms). Using these imaging parameters, 70-100% of the second division branches of the internal iliac artery could be visualized in each subject. In the second phase of this study, we evaluated the use of MR angiography in patients with intrapelvic vascular disease by comparing its accuracy in evaluating the iliac arteries with that of conventional angiography. In patients with atheromatous disease, the MR angiographic determination was consistent with that of conventional angiography in 23 of 28 visualized arterial segments (82%). In eight lesions in patients with non-stenotic vascular disease or hypervascular pelvic tumours, all lesions were demonstrated clearly with MR angiography. 2D TOF technique with high flip angle excitation is suitable for the evaluation of main iliac branches and diseased vessels.
引用
收藏
页码:140 / 146
页数:7
相关论文
共 50 条
  • [31] MAGNETIC-RESONANCE ANGIOGRAPHY OF CORONARY-ARTERIES - A 2-DIMENSIONAL VERSUS 3-DIMENSIONAL APPROACH
    HOFMAN, MBM
    VANROSSUM, AC
    PASCHAL, CB
    LI, DB
    HAACKE, M
    SPRENGER, M
    VISSER, CA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A298 - A298
  • [32] MAGNETIC-RESONANCE ANGIOGRAPHY OF THE CAROTID-ARTERY COMBINING 2-DIMENSIONAL AND 3-DIMENSIONAL ACQUISITIONS
    PAN, XM
    ANDERSON, CM
    REILLY, LM
    SALONER, D
    LEE, RE
    PEREZ, S
    KRUPSKI, WC
    RAPP, JH
    [J]. JOURNAL OF VASCULAR SURGERY, 1992, 16 (04) : 609 - 618
  • [33] QUANTITATION OF SATURATION EFFECTS VERSUS DOSE IN 3-DIMENSIONAL TIME-OF-FLIGHT MAGNETIC-RESONANCE ANGIOGRAPHY WITH BLOOD-POOL CONTRAST AGENTS
    DESSER, TS
    RUBIN, DL
    FAN, Q
    MULLER, HH
    YOUNG, SW
    KELLAR, KE
    WELLONS, JA
    LADD, DL
    TONER, JL
    SNOW, RA
    [J]. INVESTIGATIVE RADIOLOGY, 1994, 29 : S65 - S68
  • [34] NONINVASIVE ASSESSMENT OF COARCTATION OF THE AORTA - COMPARATIVE MEASUREMENTS BY 2-DIMENSIONAL ECHOCARDIOGRAPHY, MAGNETIC-RESONANCE, AND ANGIOGRAPHY
    STERN, HC
    LOCHER, D
    WALLNOFER, K
    WEBER, F
    SCHEID, KF
    EMMRICH, P
    BUHLMEYER, K
    [J]. PEDIATRIC CARDIOLOGY, 1991, 12 (01) : 1 - 5
  • [35] 2-DIMENSIONAL REGISTRATION OF MAGNETIC-RESONANCE BRAIN IMAGES
    FITCHARD, EF
    NARAYANA, PA
    [J]. MEDICAL PHYSICS, 1994, 21 (08) : 1333 - 1337
  • [36] 2-DIMENSIONAL SPECTROSCOPY - APPLICATION TO NUCLEAR MAGNETIC-RESONANCE
    AUE, WP
    BARTHOLDI, E
    ERNST, RR
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1976, 64 (05): : 2229 - 2246
  • [37] Computational Fluid Dynamics Simulations Based on Time-of-Flight Magnetic Resonance Angiography
    Topkara, Ahmet
    Okeer, Emre
    Hakyemez, Bahattin
    Isik, Esin Ozturk
    Olcay, Bahadir
    [J]. 2014 18TH NATIONAL BIOMEDICAL ENGINEERING MEETING (BIYOMUT), 2014,
  • [38] Editorial for "Quantitative Time-of-Flight Head Magnetic Resonance Angiography of Cerebrovascular Disease"
    Balu, Niranjan
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024,
  • [39] Contrast-enhanced Magnetic Resonance Angiography in Stroke Diagnostics Additional Information Compared with Time-of-Flight Magnetic Resonance Angiography?
    Alfke, K.
    Jensen, U.
    Pool, C.
    Rohr, A.
    Bruening, R.
    Weber, J.
    Bartsch, T.
    Stingele, R.
    Jansen, O.
    [J]. CLINICAL NEURORADIOLOGY, 2011, 21 (01) : 5 - 10
  • [40] Compressed Sensing 3-Dimensional Time-of-Flight Magnetic Resonance Angiography for Cerebral Aneurysms Optimization and Evaluation
    Fushimi, Yasutaka
    Fujimoto, Koji
    Okada, Tomohisa
    Yamamoto, Akira
    Tanaka, Toshiyuki
    Kikuchi, Takayuki
    Miyamoto, Susumu
    Togashi, Kaori
    [J]. INVESTIGATIVE RADIOLOGY, 2016, 51 (04) : 228 - 235