ITERATIVE PRINCIPAL AXES REGISTRATION METHOD FOR ANALYSIS OF MR-PET BRAIN IMAGES

被引:25
|
作者
DHAWAN, AP
ARATA, LK
LEVY, AV
MANTIL, J
机构
[1] KETTERING MED CTR,DEPT MAGNET RESONANCE IMAGING,KETTERING,OH 45429
[2] KETTERING MED CTR,DEPT NUCL MED,KETTERING,OH 45429
[3] BROOKHAVEN NATL LAB,UPTON,NY 11973
关键词
D O I
10.1109/10.469374
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Computerized automatic registration of MR-PET images of the brain is of significant interest for multimodality brain image analysis, In this paper, we discuss the Principal Axes Transformation for registration of three-dimensional MR and PET images, A new brain phantom designed to test MR-PET registration accuracy determines that the Principal Axes Registration method is accurate to within an average of 1.37 mm with a standard deviation of 0.78 mm, Often the PET scans are not complete in the sense that the PET volume does not match the respective MR volume. We have developed an Iterative Principal Axes Registration (IPAR) algorithm for such cases, Partial volumes of PET can be accurately registered to the complete MR volume using the new iterative algorithm. The quantitative and qualitative analyses of MR-PET image registration are presented and discussed. Results show that the new Principal Axes Registration algorithm is accurate and practical in MR-PET correlation studies.
引用
收藏
页码:1079 / 1087
页数:9
相关论文
共 50 条
  • [1] Automatic MR-PET registration algorithm
    Phillips, PJ
    Vardi, Y
    Dunn, SM
    Buchsbaum, MS
    Spiegel-Cohen, JL
    [J]. INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1998, 9 (01) : 46 - 50
  • [2] Method of human brain MR-PET image registration using maximal mutual information
    Yang, H.
    Ma, B.
    Ren, H.
    Shen, J.
    [J]. Beijing Shengwu Yixue Gongcheng/Beijing Biomedical Engineering, 2001, 20 (04): : 246 - 251
  • [3] MR-PET head motion correction based on co-registration of multicontrast MR images
    Chen, Zhaolin
    Sforazzini, Francesco
    Baran, Jakub
    Close, Thomas
    Shah, Nadim Jon
    Egan, Gary F.
    [J]. HUMAN BRAIN MAPPING, 2021, 42 (13) : 4081 - 4091
  • [4] Dynamic analysis of MR-PET data on brain tumors
    Ana Morgado
    Liliana Caldeira
    Nuno da Silva
    C Filss
    N Matela
    K-J Langen
    N Jon Shah
    [J]. EJNMMI Physics, 1 (Suppl 1)
  • [5] Human brain MR-PET image registration using mathematics morphological tools
    Yang, Hu
    Ma, Bin-rong
    Ren, Hai-ping
    Shen, Jin-hui
    [J]. Chinese Journal of Biomedical Engineering, 2002, 21 (05) : 430 - 436
  • [6] Uncertainty analysis of MR-PET image registration for precision neuro-PET imaging
    Markiewicz, Pawel J.
    Matthews, Julian C.
    Ashburner, John
    Cash, David M.
    Thomas, David L.
    De Vita, Enrico
    Barnes, Anna
    Cardoso, M. Jorge
    Modat, Marc
    Brown, Richard
    Thielemans, Kris
    Da Costa-Luis, Casper
    Alves, Isadora Lopes
    Gispert, Juan Domingo
    Schmidt, Mark E.
    Marsden, Paul
    Hammers, Alexander
    Ourselin, Sebastien
    Barkhof, Frederik
    [J]. NEUROIMAGE, 2021, 232
  • [7] Integrated registration and visualization of MR and PET brain images
    Hong, H
    Kye, H
    Shin, YG
    [J]. MEDICAL IMAGING 2004: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2004, 5367 : 617 - 627
  • [8] Hybrid surface- and voxel-based registration for MR-PET brain fusion
    Lee, H
    Hong, H
    [J]. IMAGE ANALYSIS AND PROCESSING - ICIAP 2005, PROCEEDINGS, 2005, 3617 : 930 - 937
  • [9] 3-DIMENSIONAL ANATOMICAL MODEL-BASED SEGMENTATION OF MR BRAIN IMAGES THROUGH PRINCIPAL AXES REGISTRATION
    ARATA, LK
    DHAWAN, AP
    BRODERICK, JP
    GASKILSHIPLEY, MF
    LEVY, AV
    VOLKOW, ND
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (11) : 1069 - 1078
  • [10] From simultaneous to synergistic MR-PET brain imaging: A review of hybrid MR-PET imaging methodologies
    Chen, Zhaolin
    Jamadar, Sharna D.
    Li, Shenpeng
    Sforazzini, Francesco
    Baran, Jakub
    Ferris, Nicholas
    Shah, Nadim Jon
    Egan, Gary F.
    [J]. HUMAN BRAIN MAPPING, 2018, 39 (12) : 5126 - 5144