CARBON-DIOXIDE DIGITAL SUBTRACTION ANGIOGRAPHY IN ONCOLOGICAL-INTERVENTIONAL RADIOLOGY

被引:5
|
作者
GARBAGNATI, F [1 ]
SPREAFICO, C [1 ]
MARCHIANO, A [1 ]
FRIGERIO, LF [1 ]
PATELLI, G [1 ]
GERVASONI, M [1 ]
GIOVANNARDI, G [1 ]
DAMASCELLI, B [1 ]
机构
[1] IST NAZL STUDIO & CURA TUMORI,I-20133 MILAN,ITALY
关键词
CARBON DIOXIDE; DIGITAL ANGIOGRAPHY;
D O I
10.1177/030089169508100113
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aims and background: The aim of this work is to demonstrate the usefulness of carbon dioxide, used as contrast agent, in special indications in vascular interventional oncological procedures. Methods: We studied 40 patients with digital subtraction angiography enhanced with CO2 as a contrast agent. At the same time we utilized also, in all cases, jodinated contrast agent to evaluate the different opacification gradient, the different viscosity range and the different perfusion. Results: The low viscosity of CO2 allows demonstration of the presence of even minimal blood losses in gastrointestinal tumors and enhances arteriovenous shunts in hepatocellular carcinoma. Carbon dioxide can also be employed to assess the patency of small-sized catheters for chemotherapy infusion which do not allow easy injection of the traditional iodinated contrast agents characterized by high viscosity. Conclusion: Carboangiographic study combined to digital subtraction angiography can dear some diagnostic problems and is further method to assess the outcome of angiographic interventional procedures in oncology.
引用
下载
收藏
页码:52 / 55
页数:4
相关论文
共 50 条
  • [21] Use of a compression paddle to displace bowel gas for carbon dioxide digital subtraction angiography
    Stram, ES
    Molgaard, CP
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (04) : 405 - 408
  • [22] Assessment of Image Quality and Dose Reduction Via Grid Elimination Using Statistical Pixel Angiography Over Digital Subtraction Angiography in Interventional Radiology
    Olguin, E.
    Rill, L.
    Arreola, M.
    MEDICAL PHYSICS, 2020, 47 (06) : E515 - E515
  • [23] A Comparison Between Contrast Assisted Carbon Dioxide Digital Subtraction and Pure Carbon Dioxide Digital Subtraction Angiography in Endovascular Therapy: A Sub-study of the CO2 Angiography Registry (a Prospective Multicenter Trial)
    Fukuoka, Ryota
    Shintani, Yoshiaki
    Fujihara, Masahiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : S29 - S29
  • [24] DIGITAL SUBTRACTION ANGIOGRAPHY IN INTERVENTIONAL NEURORADIOLOGY - THE VALUE OF IMMEDIATE SUBTRACTION AND SCOUT-VIEW TECHNIQUE
    SAMEC, P
    HEIMBERGER, K
    NEURORADIOLOGY, 1985, 27 (04) : 373 - 373
  • [25] Endovascular Therapy for Persistent Sciatic Artery Occlusion Using Carbon Dioxide Digital Subtraction Angiography
    Kaneko, Nobuhito
    Murata, Teppei
    Kubo, Yoshifumi
    Kagawa, Noboru
    Kuwada, Masao
    Souma, Yusuke
    Tatebayashi, Takayuki
    Noji, Sakashi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (17) : S371 - S373
  • [26] Quiescent-Interval Single-Shot Magnetic Resonance Angiography May Outperform Carbon-Dioxide Digital Subtraction Angiography in Chronic Lower Extremity Peripheral Arterial Disease
    Csore, Judit
    Suhai, Ferenc Imre
    Gyano, Marcell
    Pataki, Akos Andras
    Juhasz, Georgina
    Vecsey-Nagy, Milan
    Pal, Daniel
    Fontanini, Daniele Mariastefano
    Berczi, Akos
    Csobay-Novak, Csaba
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (15)
  • [27] The value of digital personal dosemeters in angiography/interventional radiology: Preliminary experience
    Casey, M
    Malone, DE
    RADIATION PROTECTION DOSIMETRY, 2001, 94 (1-2) : 93 - 94
  • [28] Clinical applications of digital angiography with the harmonization function in body interventional radiology
    Hidekatsu Tateishi
    Kazunori Kuroki
    Haruhiko Machida
    Toshihiko Iwamoto
    Toshiya Kariyasu
    Yuusuke Kinoshita
    Masanaka Watanabe
    Hisae Shiga
    Saori Yuda
    Kenichi Yokoyama
    Japanese Journal of Radiology, 2020, 38 : 922 - 933
  • [29] Clinical applications of digital angiography with the harmonization function in body interventional radiology
    Tateishi, Hidekatsu
    Kuroki, Kazunori
    Machida, Haruhiko
    Iwamoto, Toshihiko
    Kariyasu, Toshiya
    Kinoshita, Yuusuke
    Watanabe, Masanaka
    Shiga, Hisae
    Yuda, Saori
    Yokoyama, Kenichi
    JAPANESE JOURNAL OF RADIOLOGY, 2020, 38 (10) : 922 - 933
  • [30] The value of digital personal dosemeters in angiography/interventional radiology: Preliminary experience
    Casey, M
    Malone, DE
    DOSE AND IMAGE QUALITY IN DIGITAL IMAGING AND INTERVENTIONAL RADIOLOGY (DIMOND), 2001, : 93 - 94