DEVELOPMENT OF SEMIPORTABLE DC-SQUID MAGNETOMETER

被引:5
|
作者
KANDORI, A [1 ]
UEDA, M [1 ]
OGATA, H [1 ]
KADO, H [1 ]
机构
[1] ELECTROTECH LAB, TSUKUBA, IBARAKI 305, JAPAN
关键词
D O I
10.1109/77.403092
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A semi-portable DC-SQUID magnetometer with a liquid helium continuous how cryostat has been developed. The cryostat is 340 mm long and 50 mm in outer diameter. The pick-up coil is a co-axial, first order, differential type, 20 mm in diameter and 30 mm in baseline. The distance between the pick-up coil and the outer surface of the cryostat is 5 mm. It is easy to set this cryostat on the chest wall or on a human head. The cool down time is about 20 minutes, which is much shorter than that for a conventional storage Dewar. The white noise level, measured in a magnetically shielded room, is 8.7 fT/root Hz at 30 Hz. Noise at 1 Hz is about 30 fT/root Hz. Noise from temperature fluctuations (< 9 mK) and drift (4.22 K similar to 4.55 K) is negligible. The consumption rate of liquid helium is 10 l/h. In this paper, we show the measurement of a magnetocardiogram in a magnetically shielded room.
引用
收藏
页码:2474 / 2477
页数:4
相关论文
共 50 条
  • [31] Self-shielded multiloop dc-SQUID
    Carelli, P
    Castellano, MG
    Leoni, R
    Rossi, M
    Torrioli, G
    APPLIED SUPERCONDUCTIVITY 1995, VOLS. 1 AND 2: VOL 1: PLENARY TALKS AND HIGH CURRENT APPLICATIONS; VOL 2: SMALL SCALE APPLICATIONS, 1995, 148 : 1557 - 1560
  • [32] SIGNAL AND NOISE THEORY FOR A DC-SQUID AMPLIFIER
    MARTINIS, JM
    CLARKE, J
    JOURNAL OF LOW TEMPERATURE PHYSICS, 1985, 61 (3-4) : 227 - 236
  • [33] CORRECTION OF TRANSFER CHARACTERISTIC OF RELAXATION DC-SQUID
    BUDNIK, NN
    MINOV, YD
    SOSNITSKY, VN
    SUTKOVOY, PI
    RADIOTEKHNIKA I ELEKTRONIKA, 1993, 38 (08): : 1526 - 1531
  • [34] Electrically and magnetically resonant dc-SQUID metamaterials
    O. V. Shramkova
    N. Lazarides
    G. P. Tsironis
    A. V. Ustinov
    Applied Physics A, 2017, 123
  • [35] High-Tc dc-SQUID magnetometer and its application in eddy current non-destructive evaluation
    Qi, HH
    Lang, PL
    Zhang, MJ
    Wang, TS
    Zheng, DN
    Tian, YJ
    CRYOGENICS, 2004, 44 (10) : 695 - 699
  • [36] RELIABLE LOW-NOISE DC-SQUID
    CARELLI, P
    FOGLIETTI, V
    LEONI, R
    PULLANO, M
    IEEE TRANSACTIONS ON MAGNETICS, 1989, 25 (02) : 1026 - 1029
  • [37] MONOLITHIC THIN-FILM DC-SQUID
    DETTMANN, F
    RICHTER, W
    ALBRECHT, G
    ZAHN, W
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1979, 51 (02): : K185 - K188
  • [38] Electrically and magnetically resonant dc-SQUID metamaterials
    Shramkova, O. V.
    Lazarides, N.
    Tsironis, G. P.
    Ustinov, A. V.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2017, 123 (01):
  • [39] Magnetorelaxation (MRX) Measurements With DC-SQUID Gradiometers
    Buettner, M.
    Schmidl, F.
    Schiffler, M.
    Seidel, P.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 473 - 476
  • [40] INFLUENCE OF THE SIGNAL COIL ON DC-SQUID DYNAMICS
    SEPPA, H
    RYHANEN, T
    IEEE TRANSACTIONS ON MAGNETICS, 1987, 23 (02) : 1083 - 1086