ACCURACY OF THICK-TARGET MICRO-PIXE ANALYSIS

被引:9
|
作者
CAMPBELL, JL
TEESDALE, WJ
WANG, JX
机构
[1] Guelph-Waterloo Program for Graduate Work in Physics, University of Guelph, Guelph
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1016/0168-583X(90)90354-W
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The accuracy attainable in micro-PIXE analysis is assessed in terms of the X-ray production model and its assumptions, physical realities of the specimen, the necessary data base, and techniques of standardization. NTIS reference materials are analyzed to provide the experimental tests of accuracy. © 1990.
引用
收藏
页码:189 / 196
页数:8
相关论文
共 50 条
  • [21] Elemental imaging of rat epididymis by micro-PIXE analysis
    Homma-Takeda, S
    Nishimura, Y
    Watanabe, Y
    Imaseki, H
    Yukawa, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 210 : 368 - 372
  • [22] Analysis of geological samples by the micro-PIXE facility at KFUPM
    Ahmed, M
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 265 (01) : 39 - 45
  • [23] MICRO-PIXE ANALYSIS OF SILICATE REFERENCE-STANDARDS
    CZAMANSKE, GK
    SISSON, TW
    CAMPBELL, JL
    TEESDALE, WJ
    [J]. AMERICAN MINERALOGIST, 1993, 78 (9-10) : 893 - 903
  • [24] Analysis of geological samples by the micro-PIXE facility at KFUPM
    M. Ahmed
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2005, 265 : 39 - 45
  • [25] Micro-PIXE and PIGE analysis of individual fluid inclusions
    Zhou, SJ
    Ren, ZG
    Lin, ZR
    Yang, FJ
    [J]. RADIATION PHYSICS AND CHEMISTRY, 1996, 47 (06) : 847 - 853
  • [26] MICRO-PIXE ANALYSIS OF MAJOR ELEMENTS IN MINERAL SPECIMENS
    CAMPBELL, JL
    TEESDALE, WJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 74 (04): : 503 - 510
  • [27] ANALYSIS OF THICK-TARGET THICK-CATCHER RECOIL EXPERIMENTS
    CHRAPKOWSKI, A
    WINSBERG, L
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (01): : 94 - 94
  • [28] Micro-PIXE analyses of frozen-hydrated semi-thick biological sections
    Wang, Y. D.
    Mesjasz-Przybylowicz, J.
    Tylko, G.
    Barnabas, A. D.
    Przybylowicz, W. J.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 306 : 134 - 139
  • [29] MICRO-PIXE AND MILLI-PIXE ANALYSIS AT 40 MEV - WHY, HOW AND WHEN
    MCKEE, JSC
    DUROCHER, JJG
    GALLOP, D
    HALDEN, NM
    MATHUR, MS
    MIRZAI, A
    SMITH, GR
    YEO, YH
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 45 (1-4): : 513 - 515
  • [30] MICRO-PIXE QUANTIFICATION OF HISTOCHEMICAL REACTIONS
    ROKITA, E
    CICHOCKI, T
    DIVOUX, S
    GONSIOR, B
    HOFERT, M
    JARCZYK, L
    STRZALKOWSKI, A
    SYCH, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 49 (1-4): : 441 - 445