COMPUTER-ASSISTED LOCALIZER FOR PLANNING OF SURGERY AND INTRAOPERATIVE ORIENTATION

被引:65
|
作者
LABORDE, G
GILSBACH, J
HARDERS, A
KLIMEK, L
MOESGES, R
KRYBUS, W
机构
[1] RHEIN WESTFAL TH AACHEN,DEPT NEUROSURG,W-5100 AACHEN,GERMANY
[2] RHEIN WESTFAL TH AACHEN,DEPT ENT HEAD & NECK SURG,W-5100 AACHEN,GERMANY
[3] RHEIN WESTFAL TH AACHEN,INST MEASURING TECHNIQUES,W-5100 AACHEN,GERMANY
关键词
COMPUTER ASSISTED NEUROSURGERY; PLANNING OF SURGERY; INTRAOPERATIVE LOCALIZATION; BRAIN TUMOR;
D O I
10.1007/BF01541803
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
There is discrepancy between the exact representation of anatomical structures and tumours in the CT or MRI scan and the more or less accurate intra-operative localisation methods based mostly upon landmarks of the skull and extracerebral space and visible abnormalities of the cerebral surface. To overcome these problems of exact intra-operative localisation a Computer Assisted Localizer (CAL) is presented which allows precise intra-operative orientation without these aids. It consists of a mechanically articulated arm with six degrees of freedom with a high precision digital incremental and an image processor for 3 D data of the head. MRI and/or CT investigation is done pre-operatively with four reference markers fixed on the patient's head. They are visible on the CT or MRI slices and arc used as reference points during surgery for adjustment of the device. The co-ordinates of the digitalizer arm tip are projected into the corresponding axial, sagittal and coronal CT slices so that the system simultaneously presents three orthogonal multiplanar CT reconstructions with a reticule indicating the position of the tip of the arm. As the surgeon directs the arm to the region of interest the corresponding CT slices are displayed on the monitor at a rate of 20 slices/sec determined by the motion of the arm. The accuracy of measurement of the device itself lies within 1 mm. The accuracy is somewhat reduced however by the thickness of CT or MRI slices (routinely 2 mm slices were taken) and by deviations of the reference markers on the skin surface which amount up to 3 mm. Intra-operatively the accuracy decreases with CSF and tumour removal. Nevertheless the system has proved to be extremely useful in 50 cases to focus a trepanation and to guide the surgeon to subcortical lesions, invisible from the surface of the brain.
引用
收藏
页码:166 / 170
页数:5
相关论文
共 50 条
  • [21] Computer-Assisted Path Planning for Minimally Invasive Vascular Surgery
    HUANG Dongjin
    TANG Pengbin
    WANG Yin
    LI Hejuan
    TANG Wen
    DING Youdong
    Chinese Journal of Electronics, 2018, 27 (06) : 1241 - 1249
  • [22] COMPUTER-ASSISTED MINE PLANNING
    HENDRY, JW
    CIM BULLETIN, 1987, 80 (899): : 79 - 80
  • [23] Increase of quality in preoperative planning and intraoperative handling by the use of computer-assisted surgery and a surgical robot - an experimental study
    Jerosch, J
    Von Hasselbach, C
    Filler, T
    Peuker, E
    Rahgozar, M
    Lahmer, A
    CHIRURG, 1998, 69 (09): : 973 - 976
  • [24] COMPUTER-ASSISTED FLAP PLANNING
    KONONAS, TC
    MANIOS, A
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1991, 88 (06) : 1111 - 1112
  • [25] Advanced procedures in reconstructive and function-preserving orbital surgery by computer-assisted presurgical planning (CAPP) and computer-assisted surgery (CAS)
    Zizelmann, C
    Schramm, A
    Schön, R
    Ridder, GJ
    Maier, W
    Schipper, J
    Gellrich, NC
    HNO, 2005, 53 (05) : 428 - +
  • [26] CRANIO - computer-assisted planning for navigated and robot-assisted surgery on the skull
    Popovic, A
    Engelhardt, M
    Wu, T
    Portheine, F
    Schmieder, K
    Radermacher, K
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 1269 - 1275
  • [27] Computer-assisted Trauma Surgery
    Atesok, Kivanc
    Schemitsch, Emil H.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2010, 18 (05) : 247 - 258
  • [28] COMPUTER-ASSISTED STEREOTAXIC SURGERY
    WALKER, CF
    TANEJA, U
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 1934 - 1934
  • [29] Reliability of computer-assisted surgery as an intraoperative ruler in navigated high tibial osteotomy
    Gebhard, Florian
    Krettek, Christian
    Huefner, Tobias
    Gruetzner, Paul A.
    Stoeckle, Ulrich
    Imhoff, Andreas B.
    Lorenz, Stephan
    Ljungqvist, Jan
    Keppler, Peter
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (03) : 297 - 302
  • [30] Reliability of computer-assisted surgery as an intraoperative ruler in navigated high tibial osteotomy
    Florian Gebhard
    Christian Krettek
    Tobias Hüfner
    Paul A. Grützner
    Ulrich Stöckle
    Andreas B. Imhoff
    Stephan Lorenz
    Jan Ljungqvist
    Peter Keppler
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 297 - 302