Comparison of Intraocular Lens Power Calculation Methods after Refractive Surgery Provided by the ASCRS

被引:1
|
作者
Jung, Soyeon [1 ]
Jung, Jiwon [1 ]
机构
[1] Inha Univ, Dept Ophthalmol, Sch Med, Incheon, South Korea
来源
关键词
American Society of Cataract and Refractive Surgery (ASCRS) intraocular lens (IOL) calculator; Cataract; Corneal refractive surgery; IOL power calculation;
D O I
10.3341/jkos.2018.59.9.827
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Methods of intraocular lens (IOL) calculations for cataract surgery after myopic corneal refractive surgery were compared. Methods: The medical records of 23 eyes from 20 patients were retrospectively analyzed. Five methods - Haigis L and Barrett no history method from Post-Refractive IOL Calculator of American Society of Cataract and Refractive Surgery (ASCRS), Shammas no history method, Haigis suite from IOL Master 700, and clinical history method - were used. Results: The Barrette no history method from the ASCRS showed the lowest arithmetic errors, while the Haigis-L from the ASCRS showed the lowest absolute prediction errors (-0.38 +/- 0.99 diopters [D] and 0.76 +/- 0.68 D, respectively). The percentages of refractive prediction errors within 0.50 D and 1.00 D of the Barrett no history method were 52.2% and 82.6%, respectively. Conclusions: The Barrette no history method and Haigis-L from the ASCRS showed the smallest errors in this study. The Barrett no history method showed a high percentage of refractive prediction errors within 0.50 D and 1.00 D.
引用
收藏
页码:827 / 833
页数:7
相关论文
共 50 条
  • [11] Prediction accuracy of intraocular lens power calculation methods after laser refractive surgery
    Wu, Yubo
    Liu, Songyu
    Liao, Rongfeng
    BMC OPHTHALMOLOGY, 2017, 17
  • [12] Intraocular Lens Power Calculation After Refractive Surgery and Technologic Improvements
    Can, Cigdem
    Ilhan, Bayazit
    Polat, Sibel
    Zilelioglu, Orhan
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2006, 36 (05): : 384 - 388
  • [13] Intraocular lens power calculation with the Scheimpflug camera after refractive surgery
    Savini, Giacomo
    Ducoli, Pietro
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (08): : 1280 - 1280
  • [14] Intraocular lens power calculation in eyes after corneal refractive surgery
    Seitz, B
    Langenbucher, A
    JOURNAL OF REFRACTIVE SURGERY, 2000, 16 (03) : 349 - 361
  • [15] Updated practical intraocular lens power calculation after refractive surgery
    Jonna, Gowtham
    Channa, Prabjot
    CURRENT OPINION IN OPHTHALMOLOGY, 2013, 24 (04) : 275 - 280
  • [16] Intraocular lens power calculation after previous laser refractive surgery
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (04): : 759 - 765
  • [17] Comparison of the accuracy of intraocular lens power calculation formulas for eyes after corneal refractive surgery
    Wang, Xiao-Zhen
    Cui, Rui
    Song, Xu-Dong
    Yun, Bo
    Qian, Jin
    Ding, Ning
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (14)
  • [18] Comparative Analysis of Accuracy and Predictability of Intraocular Lens Power Calculation after Refractive Surgery: Conventional Regression Formula versus ASCRS Calculator
    Kang, Byeong Soo
    Oh, Joo Youn
    Kim, Mee Kum
    Wee, Won Ryang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [19] A new formula for intraocular lens power calculation after refractive corneal surgery
    Camellin, M
    Calossi, A
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (02) : 187 - 199
  • [20] Intraocular lens power calculation after corneal refractive surgery remains challenging
    Sun, R
    Gimbel, H
    Penno, EEA
    OPHTHALMOLOGY, 2000, 107 (02) : 226 - 227