PHOTON-BEAM CONVOLUTION USING POLYENERGETIC ENERGY DEPOSITION KERNELS

被引:29
|
作者
HOBAN, PW [1 ]
MURRAY, DC [1 ]
ROUND, WH [1 ]
机构
[1] UNIV WAIKATO,DEPT PHYS,HAMILTON,NEW ZEALAND
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1994年 / 39卷 / 04期
关键词
D O I
10.1088/0031-9155/39/4/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In photon beam convolution calculations where polyenergetic energy deposition kernels (EDKS) are used, the primary photon energy spectrum should be correctly accounted for in Monte Carlo generation of EDKS. This requires the probability of interaction, determined by the linear attenuation coefficient, mu, to be taken into account when primary photon interactions are forced to occur at the EDK origin. The use of primary and scattered EDKS generated with a fixed photon spectrum can give rise to an error in the dose calculation due to neglecting the effects of beam hardening with depth. The proportion of primary photon energy that is transferred to secondary electrons increases with depth of interaction, due to the increase in the ratio mu(ab)/mu as the beam hardens. Convolution depth-dose curves calculated using polyenergetic EDKS generated for the primary photon spectra which exist at depths of 0, 20 and 40 cm in water, show a fall-off which is too steep when compared with EGS4 Monte Carlo results. A beam hardening correction factor applied to primary and scattered 0 cm EDKS, based on the ratio of kerma to terma at each depth, gives primary, scattered and total dose in good agreement with Monte Carlo results.
引用
收藏
页码:669 / 685
页数:17
相关论文
共 50 条
  • [41] Conformal photon-beam radiotherapy of prostate carcinoma
    Bogers, JA
    van der Maazen, RWM
    Visser, AG
    EUROPEAN UROLOGY, 2002, 41 (05) : 515 - 522
  • [42] EVALUATION OF MULTILEAF COLLIMATOR DESIGN FOR A PHOTON-BEAM
    GALVIN, JM
    SMITH, AR
    MOELLER, RD
    GOODMAN, RL
    POWLIS, WD
    RUBENSTEIN, J
    SOLIN, LJ
    MICHAEL, B
    NEEDHAM, M
    HUNTZINGER, CJ
    KLIGERMAN, MM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (04): : 789 - 801
  • [43] HIGH-FLUX PHOTON-BEAM MONITOR
    MORTAZAVI, P
    WOODLE, M
    RARBACK, H
    SHU, D
    HOWELLS, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 389 - 393
  • [44] TAGGED PHOTON-BEAM FROM A JET RADIATOR
    RICCO, G
    ANGHINOLFI, M
    CORVISIERO, P
    COSTA, C
    SANZONE, M
    TAIUTI, M
    ZUCCHIATTI, A
    DESANCTIS, E
    BIANCHI, N
    SANDRI, PL
    LUCCHERINI, V
    MUCCIFORA, V
    POLLI, E
    REOLON, A
    GARIBALDI, F
    BERTOCCHI, A
    FRULLANI, S
    URCIOLI, G
    NUCLEAR PHYSICS A, 1989, 497 : C477 - C482
  • [45] BEAM PARAMETERS FOR DUAL AND SINGLE PHOTON-BEAM LINEAR ACCELERATORS
    GILLIN, MT
    MEDICAL PHYSICS, 1987, 14 (03) : 464 - 465
  • [46] THE DOSE DISTRIBUTION AT THE EDGE OF A BLOCKED PHOTON-BEAM
    WERNER, BL
    DAS, IJ
    MEDICAL PHYSICS, 1985, 12 (04) : 508 - 508
  • [47] COMPUTER ALGORITHMS FOR PHOTON-BEAM DOSE CALCULATIONS
    SONTAG, MR
    MEDICAL PHYSICS, 1986, 13 (04) : 625 - 625
  • [48] MODELING TRANSMISSION AND SCATTER FOR PHOTON-BEAM ATTENUATORS
    AHNESJO, A
    WEBER, L
    NILSSON, P
    MEDICAL PHYSICS, 1995, 22 (11) : 1711 - 1720
  • [49] HEAD AND NECK TUMORS - DOSIMETRIC CONSIDERATIONS OF MIXED-ENERGY PHOTON-BEAM THERAPY
    PROWS, J
    JANJAN, NA
    GILLIN, MT
    WILSON, JF
    RADIOLOGY, 1988, 169 (03) : 831 - 834
  • [50] SEMIEMPIRICAL CALCULATION OF DOSE DISTRIBUTIONS FOR HIGH-ENERGY PHOTON-BEAM GRID THERAPY
    MITEV, G
    SUNTHARALINGAM, N
    MEDICAL PHYSICS, 1986, 13 (04) : 592 - 592