PHOTON-BEAM CONVOLUTION USING POLYENERGETIC ENERGY DEPOSITION KERNELS

被引:29
|
作者
HOBAN, PW [1 ]
MURRAY, DC [1 ]
ROUND, WH [1 ]
机构
[1] UNIV WAIKATO,DEPT PHYS,HAMILTON,NEW ZEALAND
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1994年 / 39卷 / 04期
关键词
D O I
10.1088/0031-9155/39/4/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In photon beam convolution calculations where polyenergetic energy deposition kernels (EDKS) are used, the primary photon energy spectrum should be correctly accounted for in Monte Carlo generation of EDKS. This requires the probability of interaction, determined by the linear attenuation coefficient, mu, to be taken into account when primary photon interactions are forced to occur at the EDK origin. The use of primary and scattered EDKS generated with a fixed photon spectrum can give rise to an error in the dose calculation due to neglecting the effects of beam hardening with depth. The proportion of primary photon energy that is transferred to secondary electrons increases with depth of interaction, due to the increase in the ratio mu(ab)/mu as the beam hardens. Convolution depth-dose curves calculated using polyenergetic EDKS generated for the primary photon spectra which exist at depths of 0, 20 and 40 cm in water, show a fall-off which is too steep when compared with EGS4 Monte Carlo results. A beam hardening correction factor applied to primary and scattered 0 cm EDKS, based on the ratio of kerma to terma at each depth, gives primary, scattered and total dose in good agreement with Monte Carlo results.
引用
收藏
页码:669 / 685
页数:17
相关论文
共 50 条
  • [1] PHOTON-BEAM ENERGY DEPOSITION KERNELS FOR INVERSE RADIOTHERAPY PLANNING
    EKLOF, A
    AHNESJO, A
    BRAHME, A
    ACTA ONCOLOGICA, 1990, 29 (04) : 447 - 454
  • [2] ANALYSIS OF PHOTON-BEAM EXIT DOSE USING PHOTON POINT KERNELS
    WOO, MK
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (04): : 687 - 702
  • [3] ACQUISITION OF THE EFFECTIVE LATERAL ENERGY FLUENCE DISTRIBUTION FOR PHOTON-BEAM DOSE CALCULATIONS BY CONVOLUTION MODELS
    AHNESJO, A
    TREPP, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (07): : 973 - 985
  • [4] Accounting for the variation in collision kerma-to-terma ratio in polyenergetic photon beam convolution
    Hoban, PW
    MEDICAL PHYSICS, 1995, 22 (12) : 2035 - 2044
  • [5] A POLARIZED HIGH-ENERGY TAGGED PHOTON-BEAM
    BUSSEY, PJ
    PATERSON, CN
    RAINE, C
    HUGHESJONES, RE
    LAFFERTY, GD
    LANE, JB
    MERCER, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 211 (2-3): : 301 - 308
  • [6] OUTPUT FACTOR CONSTITUENTS OF A HIGH-ENERGY PHOTON-BEAM
    LUXTON, G
    ASTRAHAN, MA
    MEDICAL PHYSICS, 1988, 15 (01) : 88 - 91
  • [7] PHOTON-BEAM POSITION MONITOR
    IZUMI, T
    NAKAJIMA, T
    KURIHAMA, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 1951 - 1952
  • [8] SUMMARY OF PHOTON-BEAM STABILIZATION AT THE PHOTON FACTORY
    KOBAYAKAWA, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 509 - 512
  • [9] DETECTION OF LOW-ENERGY PIONS AT A TAGGED PHOTON-BEAM
    GOTHE, RW
    BECK, R
    IRMSCHER, D
    GOEBEL, J
    SCHOCH, B
    VOGT, JM
    MIN, K
    MURPHY, LY
    SO, K
    WINHOLD, EJ
    YAMAZAKI, M
    YERGIN, PF
    HALL, SJ
    KELLIE, JD
    MACGREGOR, IJD
    BRANFORD, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 276 (1-2): : 233 - 236
  • [10] THE LADON PHOTON-BEAM AT FRASCATI
    FEDERICI, L
    GIORDANO, G
    MATONE, G
    PASQUARIELLO, G
    PICOZZA, PG
    CALOI, R
    CASANO, L
    DEPASCALE, MP
    MATTIOLI, M
    POLDI, E
    SCHAERF, C
    VANNI, M
    PELFER, P
    PROSPERI, D
    FRULLANI, S
    GIROLAMI, B
    HADRONIC JOURNAL, 1981, 4 (04): : 1295 - 1304