PHOTOLUMINESCENCE LIFETIME MICROSCOPE SPECTROMETER BASED ON TIME-CORRELATED SINGLE-PHOTON COUNTING WITH AN AVALANCHE-DIODE DETECTOR

被引:35
|
作者
LOUIS, TA
RIPAMONTI, G
LACAITA, A
机构
[1] HERIOT WATT UNIV,DEPT PHYS,EDINBURGH EH14 4AS,MIDLOTHIAN,SCOTLAND
[2] POLITECN MILAN,DIPARTIMENTO ELETTRON,I-20133 MILAN,ITALY
[3] CNR,CTR ELETTRON QUANTIST & STRUMENTAZ,I-20133 MILAN,ITALY
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1990年 / 61卷 / 01期
关键词
D O I
10.1063/1.1141885
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A photoluminescence lifetime microscope spectrometer (PLμS) based on time-correlated single-photon counting (TCSPC) with a single-photon avalanche diode (SPAD) detector was developed for the investigation of the microscopic spatial fluctuations of the minority-carrier lifetime and other material parameters in gallium arsenide (GaAs) and related compound semiconductors. The high sensitivity of the TCSPC technique is essential for time-resolved photoluminescence (TRPL) measurements with a spatial resolution of the order of a few micrometers. The spatial resolution of the PLμS is compatible with the diffusion length in GaAs substrates or the dimensions of small, highly integrated GaAs devices. The PLμS is the first instrument of its kind based entirely on solid-state components, i.e., a gain-switched diode laser for pulsed excitation and an avalanche diode for single-photon detection. It is explained why, in samples dominated by nonradiative linear recombination, the relatively large excitation pulse width of the diode laser compared to a synchronously pumped dye laser does not adversely affect the timing accuracy of the measured decay time constants. It was previously shown that, by using nonlinear least-squares iterative convolution analysis, a TCSPC instrument with an instrumental response width of 70 ps (FWHM) is capable of accurately measuring fluorescence decay time constants down to 10 ps with ±2 ps timing accuracy. The PLμS is designed to take full advantage of the high repetition rates, up to 100 MHz, typical for mode-locked laser sources or gain-switched diode lasers. The data-acquisition time for a complete decay curve containing typically several hundred thousand counts is thus reduced to a few seconds. Hence, the PLμS is, in principle, suitable for scanning operation and topographical imaging.
引用
收藏
页码:11 / 22
页数:12
相关论文
共 50 条
  • [11] Increasing the collection efficiency of time-correlated single-photon counting with single-photon avalanche diodes using immersion lenses
    Pichette, Charles
    Giudice, Andrea
    Thibault, Simon
    Berube-Lauziere, Yves
    APPLIED OPTICS, 2016, 55 (33) : 9555 - 9562
  • [12] Fluorescence lifetime imaging based on time-correlated single photon counting
    Sheng C.
    Li T.
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2010, 22 (08): : 1731 - 1734
  • [13] Multiplexed single-photon counting .1. A time-correlated fluorescence lifetime camera
    McLoskey, D
    Birch, DJS
    Sanderson, A
    Suhling, K
    Welch, E
    Hicks, PJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (06): : 2228 - 2237
  • [14] Laser depth measurement based on time-correlated single-photon counting
    Massa, JS
    Wallace, AM
    Buller, GS
    Fancey, SJ
    Walker, AC
    OPTICS LETTERS, 1997, 22 (08) : 543 - 545
  • [15] Laser depth measurement based on time-correlated single-photon counting
    Department of Physics, Heriot-Watt University, Riccarton, Edinburgh EH14 4AS, United Kingdom
    不详
    Opt. Lett., 8 (543-545):
  • [16] Dynamic time-correlated single-photon counting laser ranging
    Peng H.
    Wang Y.-R.
    Meng W.-D.
    Yan P.-Q.
    Li Z.-H.
    Li C.
    Pan H.-F.
    Wu G.
    Wang, Yu-rong (yrwang152@163.com), 2018, Springer Verlag (14): : 129 - 132
  • [17] PICOSECOND FLUORESCENCE SPECTROSCOPY BY TIME-CORRELATED SINGLE-PHOTON COUNTING
    KINOSHITA, S
    KUSHIDA, T
    ANALYTICAL INSTRUMENTATION, 1985, 14 (3-4): : 503 - 524
  • [18] Dynamic time-correlated single-photon counting laser ranging
    彭欢
    王煜蓉
    孟文东
    颜佩琴
    李召辉
    李辰
    潘海峰
    吴光
    OptoelectronicsLetters, 2018, 14 (02) : 129 - 132
  • [19] Time-correlated single-photon counting laser radar in turbulence
    Henriksson, Markus
    Sjoqvist, Lars
    TECHNOLOGIES FOR OPTICAL COUNTERMEASURES VIII, 2011, 8187
  • [20] SINGLE-PHOTON AVALANCHE-DIODE FOR SINGLE-MOLECULE DETECTION
    LI, LQ
    DAVIS, LM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (06): : 1524 - 1529