Performance assessment of an evaporative cooling-assisted window air conditioner
被引:17
|作者:
Sawant, Aditya P.
[1
]
Agrawal, Neeraj
[1
]
Nanda, Prasant
[2
]
机构:
[1] Dr BA Technol Univ, Dept Mech Engn, Lonere 402103, India
[2] Veer Surendra Sai Univ Technol, Dept Mech Engn, Burla 768018, Orissa, India
关键词:
evaporative cooling;
condenser pressure;
condensate;
D O I:
10.1093/ijlct/ctr029
中图分类号:
O414.1 [热力学];
学科分类号:
摘要:
Substantial growth in refrigeration and air-conditioning industry has made a significant impact on net energy consumption. Condenser pressure is one of the critical parameters in the energy-efficient operation of refrigeration and air-conditioning systems. A novel system is developed to use the condensate, available at the cooling coil, for condenser cooling of a window air-conditioner unit by employing evaporative cooling. Performance testing of the system has shown 13% savings in energy and up to 18% enhancement in coefficient of performance. The maximum benefit of the evaporative cooling cycle over the basic cycle was found to be in the region of moderate climatic conditions.