CRITICAL CONDITIONS IN THE LIQUID-CHROMATOGRAPHY OF POLYMERS

被引:0
|
作者
HUNKELER, D [1 ]
MACKO, T [1 ]
BEREK, D [1 ]
机构
[1] SLOVAK ACAD SCI, INST POLYMER, CS-84236 BRATISLAVA, CZECHOSLOVAKIA
来源
ACS SYMPOSIUM SERIES | 1993年 / 521卷
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The liquid chromatography of polystyrene and polymethylmethacrylate have been investigated using porous silica gel packings. It has been found that the size exclusion and interactive modes of chromatography can be combined in a single column, operating isocratically, provided the thermodynamic quality of a mixed eluent is precisely controlled. In our experiments the ratio of a nonpolar thermodynamically good-solvent (toluene) and a polar nonsolvent (methanol) were systematically varied. The calibration curves were observed to shift rapidly towards the vertical, particularly for mixtures thermodynamically much poorer than the theta-composition. Furthermore, binary mobile phase compositions were identified where the retention volume was independent of the molar mass of the polymer probe. These ''limiting conditions'' have been measured on polymers up to two million daltons and have been found to be largely pressure insensitive. They potentially can be applied for the molecular weight analysis of block and graft copolymers, and for polymer blends, since the separation according to size is deconvoluted from the separation by chemical composition.
引用
收藏
页码:90 / 102
页数:13
相关论文
共 50 条
  • [21] Liquid chromatography under critical and limiting conditions: A survey of experimental systems for synthetic polymers
    Macko, T
    Hunkeler, D
    LIQUID CHROMATOGRAPHY FTIR MICROSPECTROSCOPY MICROWAVE ASSISTED SYNTHESIS, 2003, 163 : 61 - 136
  • [22] Liquid chromatography of synthetic polymers under critical conditions.: The case of single eluents and the role of Θ conditions
    Macko, T
    Hunkeler, D
    Berek, D
    MACROMOLECULES, 2002, 35 (05) : 1797 - 1804
  • [23] CHARACTERIZATION OF ETHOXYLATED FATTY ALCOHOLS USING LIQUID-CHROMATOGRAPHY WITH DENSITY AND REFRACTIVE-INDEX DETECTION .2. QUANTIFICATION IN LIQUID-CHROMATOGRAPHY UNDER CRITICAL CONDITIONS
    TRATHNIGG, B
    THAMER, D
    YAN, X
    MAIER, B
    HOLZBAUER, HR
    MUCH, H
    JOURNAL OF CHROMATOGRAPHY A, 1994, 665 (01) : 47 - 53
  • [24] MACROMOLECULE LIQUID-CHROMATOGRAPHY IN CRITICAL CONDITIONS - SEPARATION ON FUNCTIONALITIES OF HYDROXYL-CONTAINING POLYDIETHYLENE GLYCOLADIPINATES
    GORSHKOV, AV
    EVREINOV, VV
    ENTELIS, SG
    ZHURNAL FIZICHESKOI KHIMII, 1985, 59 (04): : 958 - 960
  • [25] LIQUID-CHROMATOGRAPHY OF MACROMOLECULES UNDER CRITICAL CONDITIONS - FRACTIONATION OF POLY(OXYPROPYLEN POLYOLES) IN RESPECT TO THEIR FUNCTIONALITY
    GORSKOV, AV
    JEVREINOV, VV
    LAUSECKER, B
    PASCH, H
    BECKER, H
    WAGNER, G
    ACTA POLYMERICA, 1986, 37 (11-12) : 740 - 741
  • [26] STUDY OF PERTINENCY OF PRESSURE IN LIQUID-CHROMATOGRAPHY .3. PRACTICAL METHOD FOR CHOOSING EXPERIMENTAL CONDITIONS IN LIQUID-CHROMATOGRAPHY
    MARTIN, M
    EON, C
    GUIOCHON, G
    JOURNAL OF CHROMATOGRAPHY, 1975, 110 (02): : 213 - 232
  • [27] GRADIENT ELUTION IN LIQUID-CHROMATOGRAPHY .9. SELECTION OF OPTIMAL CONDITIONS IN STEPWISE-ELUTION LIQUID-CHROMATOGRAPHY
    JANDERA, P
    CHURACEK, J
    JOURNAL OF CHROMATOGRAPHY, 1979, 170 (01): : 1 - 10
  • [28] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF BIO-POLYMERS
    REGNIER, FE
    SCIENCE, 1983, 222 (4621) : 245 - 252
  • [29] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF BIO-POLYMERS
    STUTING, HH
    KRULL, IS
    KRZYSKO, SC
    BARTH, HG
    MHATRE, R
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1989, 7 (05): : 402 - &
  • [30] A VERSATILE STRATEGY FOR THE OPTIMIZATION OF ELUENT CONDITIONS FOR LIQUID-CHROMATOGRAPHY
    MICHAUD, DP
    WARREN, FV
    BIDLINGMEYER, BA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 16 - ANYL