Agreement between inferior vena cava diameter measurements by subxiphoid versus transhepatic views

被引:22
|
作者
Kulkarni, Atul Prabhakar [1 ]
Janarthanan, S. [1 ]
Harish, M. M. [1 ]
Suhail, Siddique [1 ]
Chaudhari, Harish [1 ]
Agarwal, Vandana [2 ]
Patil, Vijaya P. [2 ]
Divatia, Jigeeshu V. [2 ]
机构
[1] Tata Mem Hosp, Div Crit Care Med, Dept Anaesthesia Crit Care & Pain, Dr E Borges Rd, Mumbai 400012, Maharashtra, India
[2] Tata Mem Hosp, Dept Anaesthesia Crit Care & Pain, Mumbai, Maharashtra, India
关键词
Fluid responsiveness; inferior vena cava collapsibility; inferior vena cava diameter; inferior vena cava distensibility; limits of agreement;
D O I
10.4103/0972-5229.171390
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Context: Correcting hypovolemia is extremely important. Central venous pressure measurement is often done to assess volume status. Measurement of inferior vena cava (IVC) is conventionally done in the subcostal view using ultrasonography. It may not be possible to obtain this view in all patients. Aims: We therefore evaluated the limits of agreement between the IVC diameter measurement and variation in subcostal and that by the lateral transhepatic view. Settings and Design: Prospective study in a tertiary care referral hospital intensive care unit. Subjects and Methods: After Institutional Ethics Committee approval and informed consent, we obtained 175 paired measurements of the IVC diameter and variation in both the views in adult mechanically ventilated patients. The measurements were carried out by experienced researchers. We then obtained the limits of agreement for minimum, maximum diameter, percentage variation of IVC in relation to respiration. Statistical Analysis Used: Bland-Altman's limits of agreement to get precision and bias. Results: The limits of agreement were wide for minimum and maximum IVC diameter with variation of as much as 4 mm in both directions. However, the limits of agreement were much narrower when the percentage variation in relation to respiration was plotted on the Bland-Altman plot. Conclusions: We conclude that when it is not possible to obtain the subcostal view, it is possible to use the lateral transhepatic view. However, using the percentage variation in IVC size is likely to be more reliable than the absolute diameter alone. It is possible to use both views interchangeably.
引用
收藏
页码:719 / 722
页数:4
相关论文
共 50 条
  • [21] Influence of angle variation between right hepatic vein and inferior vena cava on inferior vena cava diaphragm
    Zhang, Haowei (howiezh@sina.com), 1600, West China Hospital, Sichuan Institute of Biomedical Engineering (33):
  • [22] Ultrasonographic measurements of the inferior vena cava diameter in newborns: is it a useful tool for choosing an umbilical venous catheter?
    Galdo, Francesca
    Trappan, Antonella
    Cossovel, Francesca
    Rodriguez-Perez, Carmen
    Ronfani, Luca
    Montaldo, Paolo
    Bibalo, Cristina
    Travan, Laura
    Risso, Francesco Maria
    FRONTIERS IN PEDIATRICS, 2023, 11
  • [23] The association between post-delivery inferior vena cava diameter and Postpartum hemoglobin levels
    Noy, Ariel
    Barzilay, Eran
    Sason, Anna Babakine
    Sadon, Alisa
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2024, 230 (01) : S155 - S155
  • [24] Inferior Vena Cava Diameter and Left Atrial Diameter Measure Volume but Not Dry Weight
    Agarwal, Rajiv
    Bouldin, J. Michael
    Light, Robert P.
    Garg, Ashok
    CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2011, 6 (05): : 1066 - 1072
  • [25] The utility and limitation of inferior vena cava diameter as a dry weight marker
    Shibata, Eriko
    Nagai, Kojiro
    Ueda, Sayo
    Ono, Hiroyuki
    Nishimura, Kenji
    Inagaki, Taizo
    Minato, Masanori
    Kishi, Fumi
    Tamaki, Masanori
    Murakami, Taichi
    Kishi, Seiji
    Abe, Hideharu
    Yokota, Narushi
    Minakuchi, Jun
    Doi, Toshio
    JOURNAL OF MEDICAL INVESTIGATION, 2019, 66 (1-2): : 172 - 177
  • [26] Bioimpedance and inferior vena cava diameter for assessment of dialysis dry weight
    Dietel, T
    Filler, G
    Grenda, R
    Wolfish, N
    PEDIATRIC NEPHROLOGY, 2000, 14 (10-11) : 903 - 907
  • [27] Unveiling the Link: Minimum Inferior Vena Cava Diameter and Thrombosis Risk
    Gong, Maofeng
    Qian, Cheng
    Jiang, Rui
    He, Xu
    Gu, Jianping
    ACADEMIC RADIOLOGY, 2024, 31 (10) : 4129 - 4138
  • [28] Decreased inferior vena cava diameter as an early marker in postpartum hemorrhage
    Massalha, M.
    Faranish, R.
    Romano, S.
    Salim, R.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2022, 59 (02) : 234 - 240
  • [29] Prognostic capacity of inferior vena cava diameter for severe postpartum hemorrhage
    Sert, Zekiye Soykan
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2021, 267 : 6 - 10
  • [30] Bioimpedance and inferior vena cava diameter for assessment of dialysis dry weight
    Tobias Dietel
    Guido Filler
    Ryszard Grenda
    Norman Wolfish
    Pediatric Nephrology, 2000, 14 : 903 - 907