CHRONIC EVALUATIONS OF VENTRICULAR EJECTION PHASE DYNAMICS DURING ABDOMINAL LEFT-VENTRICULAR ASSIST DEVICE (ALVAD) PUMPING IN AWAKE, UNANESTHETIZED CALF

被引:0
|
作者
IGO, SR
HIBBS, CW
FUQUA, JM
WALKER, MG
NAIFEH, JG
NORMAN, JC
机构
[1] ST LUKES EPISCOPAL HOSP, TEXAS HEART INST, CARDIOVASC SURG RES LABS, HOUSTON, TX 77025 USA
[2] TEXAS CHILDRENS HOSP, MED CTR, HOUSTON, TX 77025 USA
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
引用
收藏
页码:480 / 487
页数:8
相关论文
共 50 条
  • [21] SEQUENTIAL ELECTROCARDIOGRAPHIC ANALYSIS OF STONE HEART SYNDROME IN A PATIENT SUPPORTED SIX DAYS WITH AN ABDOMINAL LEFT-VENTRICULAR ASSIST DEVICE (ALVAD)
    SOLOMON, AR
    STURM, JT
    MASSIN, EK
    NORMAN, JC
    [J]. CARDIOVASCULAR DISEASES, 1979, 6 (02): : 173 - 180
  • [22] RENIN SECRETION DURING NONPULSATILE LEFT-VENTRICULAR BYPASS IN AWAKE CALF
    SHOOR, PM
    MARZEC, UM
    GRIFFITH, LF
    HAMMILL, F
    DILLEY, RB
    BERNSTEIN, EF
    [J]. SURGICAL FORUM, 1978, 29 : 120 - 121
  • [23] CHRONIC LEFT-VENTRICULAR SUPPORT WITH A VENTED ELECTRIC ASSIST DEVICE
    FRAZIER, OH
    [J]. ANNALS OF THORACIC SURGERY, 1993, 55 (01): : 273 - 275
  • [24] HEMODYNAMIC-EFFECTS OF AN IMPLANTABLE LEFT-VENTRICULAR ASSIST DEVICE (LVAD) IN THE CALF
    WITHINGTON, PS
    GRAHAM, T
    CAREY, C
    WHITE, D
    LEWIS, CT
    COLVIN, MP
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1989, 63 (02) : P243 - P243
  • [25] PREFABRICATION DESIGN CONSIDERATIONS FOR A LONG-TERM ELECTRICALLY-ACTUATED ABDOMINAL LEFT-VENTRICULAR ASSIST DEVICE (E-TYPE ALVAD)
    STURM, JT
    IGO, SR
    POIRIER, VL
    KEISER, JT
    HIBBS, CW
    FUQUA, JM
    EDMONDS, CH
    HOLUB, DA
    MCGEE, MG
    FUHRMAN, TM
    JOSEPH, AR
    NORMAN, JC
    [J]. CARDIOVASCULAR DISEASES, 1978, 5 (04): : 425 - 436
  • [26] LEFT-VENTRICULAR SHAPE DURING EJECTION PHASE IN CORONARY PATIENTS
    TIKHONOV, KB
    MINKO, BA
    LITVINOV, PD
    GUT, RE
    NOVIKOV, VI
    [J]. KARDIOLOGIYA, 1987, 27 (12) : 31 - &
  • [27] EFFECT OF RATE ON LEFT-VENTRICULAR VOLUMES AND EJECTION FRACTION DURING CHRONIC VENTRICULAR PACING
    NARAHARA, KA
    BLETTEL, ML
    [J]. CIRCULATION, 1983, 67 (02) : 323 - 329
  • [28] CHRONIC INVIVO EVALUATIONS OF A LONG-TERM, IMPLANTABLE LEFT-VENTRICULAR ASSIST SYSTEM
    MCGEE, MG
    IGO, SR
    FUQUA, JM
    CREAGER, GJ
    URRUTIA, CO
    POOL, GE
    PAINVIN, GA
    KRUDEWIG, TW
    CHAMBERS, JA
    CLAY, WC
    FRAZIER, OH
    [J]. TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1983, 29 : 97 - 102
  • [29] MANAGEMENT OF CHRONIC LEFT-VENTRICULAR ASSIST DEVICE PERCUTANEOUS LEAD INSERTION SITES
    HRAVNAK, M
    GEORGE, E
    KORMOS, RL
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 1993, 12 (05): : 856 - 863
  • [30] Control of Left Ventricular Load and Pulsatility by a Continuous-flow Left Ventricular Assist Device With a Native Heart Load Control System in Chronic Awake Phase
    Date, Kazuma
    Nishimura, Takashi
    Kishimoto, Satoru
    Takewa, Yoshiaki
    Ono, Minoru
    Tatsumi, Eisuke
    [J]. CIRCULATION, 2014, 130