A HIGH-RESOLUTION FLYING MAGNETIC DISK RECORDING-SYSTEM WITH ZERO REPRODUCE SPACING LOSS

被引:17
|
作者
GOOCH, B
NIEDERMEYER, R
WOOD, R
PISHARODY, R
机构
[1] Ampex Corp. 401 Broadway, Redwood City
[2] IBM Corp., Magnetic Recording Institute
关键词
D O I
10.1109/20.278679
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel method has been developed for reducing the reproduce spacing loss and thereby potentially allowing increased linear densities on a disc media while maintaining a reasonable flying height. A laminated magnetic recording media is composed of a high coercivity layer in which the data signals are stored and a thin, low coercivity, high permeability, overlayer which is called a keeper layer. A small DC bias applied to the head saturates a section of the keeper layer forming a virtual gap that is in direct contact with the high coercivity storage layer. This virtual gap functions as a transducing zone that enables a signal flux to be transferred from unsaturated keeper regions to the pole pieces of the flying head. Experimental results show that a considerable reduction, if not elimination of the reproduce spacing loss is achieved using the keepered disc. Additionally the keepered disc virtual gap was found to be about 10% smaller than the physical gap in the flying head that induced it. A series of simulations were conducted using finite difference models which confirmed the trends observed in the experimental data.
引用
下载
收藏
页码:4549 / 4554
页数:6
相关论文
共 50 条
  • [41] A SIMPLE HIGH-PERFORMANCE HIGH-RESOLUTION ELECTRON ENERGY-LOSS SPECTROSCOPY SYSTEM
    UNWIN, R
    STENZEL, W
    GARBOUT, A
    CONRAD, H
    HOFFMANN, FM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1984, 55 (11): : 1809 - 1813
  • [42] Dynamic High-Resolution Sonography Compared to Magnetic Resonance Imaging for Diagnosis of Temporomandibular Joint Disk Displacement
    Habashi, Hadeel
    Eran, Ayelet
    Blumenfeld, Israel
    Gaitini, Diana
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (01) : 75 - 82
  • [43] Simulation of high-resolution MFM tips for high-density magnetic recording media with low bit aspect ratio
    Saito, H
    Rheem, YW
    Ishio, S
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2005, 287 : 102 - 106
  • [44] SUPERCONDUCTING MAGNETIC SYSTEM OF A 400-MHZ HIGH-RESOLUTION NMR SPECTROMETER
    TARYANIK, NV
    LAPTIENKO, AY
    LUTSENKO, VP
    SHAPARENKO, VV
    MATVEENKO, EG
    MEASUREMENT TECHNIQUES USSR, 1989, 32 (11): : 1107 - 1109
  • [45] High-resolution magnetic sensors in ferrite/piezoelectric heterostructure with giant magnetodielectric effect at zero bias field
    Zhang, Jitao
    Liu, Jiahui
    Zhang, Qingfang
    Filippov, D. A.
    Li, Kang
    Wu, Jie
    Tao, Jiagui
    Jiang, Liying
    Cao, Lingzhi
    Srinivasan, Gopalan
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (04): : 1ENG
  • [46] High-resolution magnetic resonance spectroscopy in unstable fields via intermolecular zero-quantum coherences
    Lin, Meijin
    Chen, Xi
    Cai, Shuhui
    Chen, Zhong
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2010, 12 (23) : 6014 - 6020
  • [47] HIGH-DENSITY RECORDING WITH A SUPER-RESOLUTION MAGNETOOPTICAL DISK USING MAGNETIC-FIELD MODULATION METHOD
    MURAKAMI, Y
    TAKAHASHI, A
    TERASHIMA, S
    JOURNAL OF PHYSICS AND CHEMISTRY OF SOLIDS, 1995, 56 (11) : 1535 - 1541
  • [48] Application of a multichannel detection system to the high-resolution fast electron energy loss spectrometer
    Liu, XJ
    Zhu, LF
    Jiang, XM
    Yuan, ZS
    Cai, B
    Chen, XJ
    Xu, KZ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (08): : 3357 - 3361
  • [49] HIGH-RESOLUTION ELECTRON-ENERGY LOSS SPECTROSCOPY ON MO(100) /CO SYSTEM
    THUAULT, C
    BALLU, Y
    JOURNAL DE MICROSCOPIE ET DE SPECTROSCOPIE ELECTRONIQUES, 1981, 6 (06): : 575 - 582
  • [50] HIGH-T-C RF SQUID MAGNETOMETER SYSTEM FOR HIGH-RESOLUTION MAGNETIC IMAGING
    Tinchev, S. S.
    Hinken, J. H.
    Stiller, M.
    Baranyak, A.
    Hartmann, D.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1993, 3 (01) : 2469 - 2471