A numerical model of an Active Magnetic Regenerator for refrigeration at room temperature

被引:0
|
作者
Aprea, Ciro [1 ]
Maiorino, Angelo [1 ]
Mastrullo, Rita [2 ]
机构
[1] Univ Salerno, Dept Mech Engn, Via Ponte Don Melillo 1, I-84084 Fisciano Salerno, Italy
[2] Univ Naples Federico II, DETEC, I-80125 Naples, Italy
关键词
magnetocaloric effect; magnetic refrigeration; entropy; gadolinium; mathematical model;
D O I
10.1504/IJETM.2007.013240
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, a numerical model of an Active Magnetic Regenerator (AMR) for refrigeration at room temperature has been evaluated. The model is based on the equation of state of a homogeneous ferromagnetic with reference to the gadolinium used as magnetocaloric substance. In this way the curves of the magnetisation and of the specific heat at constant magnetic field and of the adiabatic temperature variation for the gadolinium subject to a variable magnetic field have been obtained using the Brillouin function.
引用
收藏
页码:113 / 133
页数:21
相关论文
共 50 条
  • [21] Study of geometries of active magnetic regenerators for room temperature magnetocaloric refrigeration
    Lei, Tian
    Engelbrecht, Kurt
    Nielsen, Kaspar K.
    Veje, Christian T.
    APPLIED THERMAL ENGINEERING, 2017, 111 : 1232 - 1243
  • [22] Numerical analysis of a reciprocating active magnetic regenerator
    Lionte, Sergiu
    Vasile, Carmen
    Siroux, Monica
    APPLIED THERMAL ENGINEERING, 2015, 75 : 871 - 879
  • [23] ACTIVE MAGNETIC REGENERATOR: A NUMERICAL AND EXPERIMENTAL STUDY
    Niknia, I.
    Rowe, A.
    6TH IIR/IIF INTERNATIONAL CONFERENCE ON MAGNETIC REFRIGERATION (THERMAG VI), 2014, : 57 - 58
  • [24] Gd-Zn alloys as active magnetic regenerator materials for magnetic refrigeration
    Pecharsky, VK
    Gschneidner, KA
    CRYOCOOLERS 10, 1999, : 629 - 637
  • [25] Mathematical Modelling of Active Magnetic Regenerator Refrigeration System for Design Considerations
    Effatpisheh, Aref
    Vadiee, Amir
    Monfared, Behzad A.
    ENERGIES, 2020, 13 (23)
  • [26] A flexible numerical model to study an active magnetic refrigerator for near room temperature applications
    Aprea, Ciro
    Maiorino, Angelo
    APPLIED ENERGY, 2010, 87 (08) : 2690 - 2698
  • [27] Progress of room temperature magnetic refrigeration technology
    Li Zhen-Xing
    Li Ke
    Shen Jun
    Dai Wei
    Gao Xin-Qiang
    Guo Xiao-Hui
    Gong Mao-Qiong
    ACTA PHYSICA SINICA, 2017, 66 (11)
  • [28] Special issue - Magnetic refrigeration at room temperature
    Auracher, Hein
    Egolf, Peter W.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (08): : 1235 - 1238
  • [29] Analysis of room temperature magnetic regenerative refrigeration
    Shir, F
    Mavriplis, C
    Bennett, LH
    Della Torre, E
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (04): : 616 - 627
  • [30] Review on research of room temperature magnetic refrigeration
    Yu, BF
    Gao, Q
    Zhang, B
    Meng, XZ
    Chen, Z
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (06): : 622 - 636