Sonographic measurement of thyroid gland volume: A comparison of 2D and 3D ultrasound

被引:9
|
作者
Ying, Michael [1 ]
Sin, Man-hong [1 ]
Pang, Shuk-fan [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Optometry & Radiog, Kowloon, Hong Kong, Peoples R China
关键词
Thyroid volume; 2D ultrasound; 3D ultrasound; Reproducibility;
D O I
10.1016/j.radi.2005.03.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aims This study was undertaken to investigate the inter-observer reproducibility of 2D and 3D ultrasound in the measurement of thyroid gland volume. The symmetry of thyroid lobes in healthy subjects was also investigated. Materials and methods The volume of the left and right lobes of the thyroid gland was measured in 20 healthy subjects (10 men and 10 women) using 2D and 3D ultrasound. On 2D ultrasound, the thyroid lobe volume was calculated by ellipsoid equation (volume = pi/6 x craniocaudal x mediolateral x anteroposterior dimensions), whereas 3D ultrasound volumetric measurements were performed with a 3D add-on system. In each subject, the thyroid gland was scanned by two operators to investigate inter-observer variability. Results There was a moderate agreement between 2D and 3D ultrasound in the measurement of thyroid volume (r = 0.77). 3D ultrasound (90%) had a higher inter-observer reproducibility than 2D ultrasound (85%) in the measurements. About 74% of healthy subjects had the right thyroid lobe larger than the left lobe. Conclusion 3D ultrasound is useful in the measurement of thyroid volume with a higher reproducibility than 2D ultrasound. Asymmetry of thyroid lobes was noted in healthy subjects. (C) 2005 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:242 / 248
页数:7
相关论文
共 50 条
  • [41] A COMPARISON OF 2D AND 3D NUMERICAL SIMULATION FOR TUNNEL EXCAVATION ACCOMPANIED BY MEASUREMENT RESULTS
    Bacic, Mario
    Marcic, Danijela
    Kovacevic, Meho Sasa
    ROAD AND RAIL INFRASTRUCTURE II, 2012, : 797 - 803
  • [42] 2D or 3D?
    Mills, R
    COMPUTER-AIDED ENGINEERING, 1996, 15 (08): : 4 - 4
  • [43] 2D and 3D Palmprint Extraction by an Automated Ultrasound System
    Iula, Antonio
    Hine, Gabriel
    Ramalli, Alessandro
    Guidi, Francesco
    Boni, Enrico
    APPLICATIONS IN ELECTRONICS PERVADING INDUSTRY, ENVIRONMENT AND SOCIETY, APPLEPIES 2014, 2016, 351 : 83 - 89
  • [44] 3D Kidney Reconstruction from 2D Ultrasound Images
    Teresa Alvarez-Gutierrez, Mariana
    Rodrigo Mejia-Rodriguez, Aldo
    Alejandro Cruz-Guerrero, Ines
    Roman Arce-Santana, Edgar
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 393 - 400
  • [45] Similarity Registration Problems for 2D/3D Ultrasound Calibration
    Vasconcelos, Francisco
    Peebles, Donald
    Ourselin, Sebastien
    Stoyanov, Danail
    COMPUTER VISION - ECCV 2016, PT VI, 2016, 9910 : 171 - 187
  • [46] Prenatal Diagnosis of a Case of Ectrodactyly in 2D and 3D Ultrasound
    Kang, A.
    Visca, E.
    Bruder, E.
    Holzgreve, W.
    Struben, H.
    Tercanli, S.
    ULTRASCHALL IN DER MEDIZIN, 2009, 30 (02): : 121 - 123
  • [47] Calibration of 2D Ultrasound in 3D Space for Robotic Biopsies
    Ahmad, Awais
    Cavusoglu, M. Cenk
    Bebek, Ozkan
    PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS (ICAR), 2015, : 40 - 45
  • [48] A deep kiss with 2D and dynamic 3D ultrasound imaging
    Newton, N
    CLINICAL RADIOLOGY, 2000, 55 (12) : 987 - 987
  • [49] First Trimester Diagnosis of Sirenomelia by 2D and 3D Ultrasound
    Contu, Rossana
    Zoppi, Maria A.
    Axiana, Carolina
    Ibba, Rosa M.
    Monni, Giovanni
    FETAL DIAGNOSIS AND THERAPY, 2009, 26 (01) : 41 - 44
  • [50] REPRESENTATIVE VOLUME ELEMENT IN 2D FOR DISKS AND IN 3D FOR BALLS
    Rylko, Natalia
    JOURNAL OF MECHANICS OF MATERIALS AND STRUCTURES, 2014, 9 (04) : 427 - 439