DETERMINATION OF AMPICILLIN IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING ULTRAVIOLET DETECTION

被引:14
|
作者
AKHTAR, MJ [1 ]
KHAN, S [1 ]
KHAN, MAS [1 ]
机构
[1] WELLCOME PAKISTAN LTD,RES & DEV LABS,D-43,SITE,KARACHI,PAKISTAN
关键词
AMPICILLIN; REVERSED-PHASE HPLC; ISOCRATIC ELUTION; UV DETECTION; HUMAN PLASMA;
D O I
10.1016/0731-7085(93)80031-U
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance liquid chromatographic method with isocratic elution has been developed for the determination of ampicillin in human plasma. The method comprises injection of the plasma after protein precipitation on to a reversed-phase C18 column, using phosphate buffer (pH 3.5)-methanol as the mobile phase. The method involves UV detection at 225 nm. This method provides a simple technique for the rapid analysis of ampicillin within the concentration range 0.2-25 mug ml-1 with a high degree of accuracy and precision.