ASBESTOS AND OTHER FIBER LEVELS IN BUILDINGS

被引:17
|
作者
ALTREEWILLIAMS, S
PRESTON, JS
机构
[1] OCCUPAT HYG CONSULTANTS, CANBERRA, AUSTRALIA
[2] AUSTRALIAN NATL UNIV, SCANNING ELECTRON MICROSCOPY UNIT, CANBERRA, ACT 2600, AUSTRALIA
来源
ANNALS OF OCCUPATIONAL HYGIENE | 1985年 / 29卷 / 03期
关键词
D O I
10.1093/annhyg/29.3.357
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
A Nuclepore filter/SEM method was used to determine the airborne concentration of asbestos and other fibres in office and plant buildings. The monitoring/SEM/XRMA conditions were chosen to match the collection efficiency, fibre detectability and convenience of the membrane filter/optical microscope method. Additionally, the SEM/XRMA technique provides identification of counted fibres and a detection limit of 1 fiber l.-1 under the routine conditions of occupational hygiene sampling. Application of the method to the collection of 193 air samples in the occupied areas of 22 asbestos-containing office and plant bulidings gave the following asbestos counts: 22 fibre l.-1 (1 sample); 3 fibre l.-1 (3 samples); 2 fibre l.-1 (5 samples); 1 fibre l.-1(22 samples); 0 fibre l.-1 (162 samples). Organic fibre levels ranged from 63-0 fibre l.-1 (median = 4 fibre l.-1). Mineral (non-asbestos) fibre levels ranged from 13 to 0 fibre l.-1 (median = 1 fibre l.-1).
引用
收藏
页码:357 / 363
页数:7