Effects of shielding the radiosensitive superficial organs of ORNL pediatric phantoms on dose reduction in computed tomography

被引:24
|
作者
Akhlaghi, Parisa [1 ]
Miri-Hakimabad, Hashem [1 ]
Rafat-Motavalli, Laleh [1 ]
机构
[1] Ferdowsi Univ Mashhad, Fac Sci, Dept Phys, Azadi Sq, Mashhad 917751436, Iran
关键词
Image quality; lead and bismuth; Monte Carlo simulation; superficial organs' doses;
D O I
10.4103/0971-6203.144490
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In computed tomography (CT), some superficial organs which have increased sensitivity to radiation, receive doses that are significant enough to be matter of concern. Therefore, in this study, the effects of using shields on the amount of dose reduction and image quality was investigated for pediatric imaging. Absorbed doses of breasts, eyes, thyroid and testes of a series of pediatric phantoms without and with different thickness of bismuth and lead were calculated by Monte Carlo simulation. Appropriate thicknesses of shields were chosen based on their weights, X-ray spectrum, and the amount of dose reduction. In addition, the effect of lead shield on image quality of a simple phantom was assessed quantitatively using region of interest (ROI) measurements. Considering the maximum reduction in absorbed doses and X-ray spectrum, using a lead shield with a maximum thickness of 0.4 mm would be appropriate for testes and thyroid and two other organs (which are exposed directly) should be protected with thinner shields. Moreover, the image quality assessment showed that lead was associated with significant increases in both noise and CT attenuation values, especially in the anterior of the phantom. Overall, the results suggested that shielding is a useful optimization tool in CT.
引用
收藏
页码:238 / 246
页数:9
相关论文
共 50 条
  • [41] State of the art: Technologies for computed tomography dose reduction
    Gunn M.L.D.
    Kohr J.R.
    Emergency Radiology, 2010, 17 (3) : 209 - 218
  • [42] Reduction Of Uterus Dose In Clinical Thoracic Computed Tomography
    Danova, D.
    Keil, B.
    Kastner, B.
    Wulff, J.
    Fiebich, M.
    Zink, K.
    Klose, K. J.
    Heverhagen, J. T.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (12): : 1091 - 1096
  • [43] Effects of Different Fields of View and Rotation Angles on Radiation Doses to Highly Radiosensitive Organs in Children Using Dental Cone Beam Computed Tomography
    Ito, Misaki
    Kojima, Ikuho
    Iikubo, Masahiro
    Onodera, Shu
    Sai, Masahiro
    Fujisawa, Masaki
    Kato, Toshiki
    Nakamura, Masaaki
    Zuguchi, Masayuki
    Chida, Koichi
    APPLIED SCIENCES-BASEL, 2024, 14 (19):
  • [44] Streak Artifact Reduction in Low Dose Computed Tomography
    Zamyatin, Alexander A.
    Yang, Zhi
    Akino, Naruomi
    Nakanishi, Satoru
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4150 - +
  • [45] New dose reduction techniques for thoracic computed tomography
    Revel, M. -P.
    REVUE DES MALADIES RESPIRATOIRES, 2013, 30 (02) : 161 - 164
  • [46] Radiation exposure in spiral computed tomography -: Dose distribution and dose reduction
    Hidajat, N
    Mäurer, J
    Schröder, RJ
    Wolf, M
    Vogl, T
    Felix, R
    INVESTIGATIVE RADIOLOGY, 1999, 34 (01) : 51 - 57
  • [47] Organ dose measurement in computed tomography using thermoluminescence dosimeter in locally developed phantoms
    Akpochafor M.O.
    Adeneye S.O.
    Habeebu M.Y.
    Omojola A.D.
    Adedewe N.A.
    Adedokun A.R.
    Joseph A.O.
    Ajibade O.S.
    Etim V.E.
    Aweda M.A.
    Iranian Journal of Medical Physics, 2019, 16 (02) : 126 - 132
  • [48] Radiation dose reduction in pediatric computed tomography (CT) using deep convolutional neural network denoising
    Horst, K. K.
    Zhou, Z.
    Hull, N. C.
    Thacker, P. G.
    Kassmeyer, B. A.
    Johnson, M. P.
    Demirel, N.
    Missert, A. D.
    Weger, K.
    Yu, L.
    CLINICAL RADIOLOGY, 2025, 80
  • [49] Evaluation of the impact of organ-specific dose reduction on image quality in pediatric chest computed tomography
    Johannes Boos
    Patric Kröpil
    Dirk Klee
    Philipp Heusch
    Lars Schimmöller
    Jörg Schaper
    Gerald Antoch
    Rotem S. Lanzman
    Pediatric Radiology, 2014, 44 : 1065 - 1069
  • [50] Evaluation of the impact of organ-specific dose reduction on image quality in pediatric chest computed tomography
    Boos, Johannes
    Kroepil, Patric
    Klee, Dirk
    Heusch, Philipp
    Schimmoeller, Lars
    Schaper, Joerg
    Antoch, Gerald
    Lanzman, Rotem S.
    PEDIATRIC RADIOLOGY, 2014, 44 (09) : 1065 - 1069