Effects of shielding the radiosensitive superficial organs of ORNL pediatric phantoms on dose reduction in computed tomography

被引:24
|
作者
Akhlaghi, Parisa [1 ]
Miri-Hakimabad, Hashem [1 ]
Rafat-Motavalli, Laleh [1 ]
机构
[1] Ferdowsi Univ Mashhad, Fac Sci, Dept Phys, Azadi Sq, Mashhad 917751436, Iran
关键词
Image quality; lead and bismuth; Monte Carlo simulation; superficial organs' doses;
D O I
10.4103/0971-6203.144490
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In computed tomography (CT), some superficial organs which have increased sensitivity to radiation, receive doses that are significant enough to be matter of concern. Therefore, in this study, the effects of using shields on the amount of dose reduction and image quality was investigated for pediatric imaging. Absorbed doses of breasts, eyes, thyroid and testes of a series of pediatric phantoms without and with different thickness of bismuth and lead were calculated by Monte Carlo simulation. Appropriate thicknesses of shields were chosen based on their weights, X-ray spectrum, and the amount of dose reduction. In addition, the effect of lead shield on image quality of a simple phantom was assessed quantitatively using region of interest (ROI) measurements. Considering the maximum reduction in absorbed doses and X-ray spectrum, using a lead shield with a maximum thickness of 0.4 mm would be appropriate for testes and thyroid and two other organs (which are exposed directly) should be protected with thinner shields. Moreover, the image quality assessment showed that lead was associated with significant increases in both noise and CT attenuation values, especially in the anterior of the phantom. Overall, the results suggested that shielding is a useful optimization tool in CT.
引用
收藏
页码:238 / 246
页数:9
相关论文
共 50 条
  • [1] Protection of superficial organs using bismuth and iodine shielding during computed tomography in phantoms
    Kweon, Dae Cheol
    Lee, Jong-Woong
    Choi, Jiwon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2022, 81 (01) : 59 - 67
  • [2] Protection of superficial organs using bismuth and iodine shielding during computed tomography in phantoms
    Dae Cheol Kweon
    Jong-Woong Lee
    Jiwon Choi
    Journal of the Korean Physical Society, 2022, 81 : 59 - 67
  • [3] Radiation Dose to Radiosensitive Organs during Head/Sinus Computed Tomography Procedure
    Taha, Taha Mohamed
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2023, 56 (01): : 112 - 116
  • [4] PEDIATRIC DOSE REDUCTION IN COMPUTED TOMOGRAPHY
    Frush, Donald P.
    HEALTH PHYSICS, 2008, 95 (05): : 518 - 527
  • [5] Dose Reduction Techniques in Pediatric Computed Tomography
    Odle, Teresa G.
    RADIOLOGIC TECHNOLOGY, 2019, 91 (02)
  • [6] Location of radiosensitive organs inside pediatric anthropomorphic phantoms: Data required for dosimetry
    Inkoom, Stephen
    Raissaki, Maria
    Perisinakis, Kostas
    Maris, Thomas G.
    Damilakis, John
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 882 - 888
  • [7] On the use of pediatric phantoms in the dose evaluation during computed tomography (CT) thorax examinations
    Giacco, G
    Cannata, V
    Furetta, C
    Santopietro, F
    Fariello, G
    MEDICAL PHYSICS, 2001, 28 (02) : 199 - 204
  • [8] Effective Dose Normalized to Dose Length Product for Pediatric and Adult Reference Phantoms in Computed Tomography Examinations
    Lamart, S.
    Kim, K.
    Bolch, W.
    Lee, C.
    MEDICAL PHYSICS, 2012, 39 (06) : 3634 - 3634
  • [9] Dose Reduction in Pediatric Computed Tomography with Automated Exposure Control
    Alibek, Sedat
    Brand, Martin
    Suess, Christoph
    Wuest, Wolfgang
    Uder, Michael
    Greess, Holger
    ACADEMIC RADIOLOGY, 2011, 18 (06) : 690 - 693
  • [10] Multidetector computed tomography (MDCT) and dose reduction in pediatric radiology
    Heyer, C. M.
    MONATSSCHRIFT KINDERHEILKUNDE, 2011, 159 (04) : 343 - 349