A simple measurement of the pH of root apoplast by the fluorescence ratio method

被引:2
|
作者
Nishiyama, Hiroki [1 ]
Ohya, Tomoyuki [1 ]
Tanoi, Keitaro [1 ]
Nakanishi, Tomoko M. [1 ]
机构
[1] Univ Tokyo, Grad Sch Agr & Life Sci, Bunkyo Ku, 1-1-1 Yayoi, Tokyo 1138657, Japan
来源
PLANT ROOT | 2008年 / 2卷
关键词
Aluminum; apoplastic pH; fluorescence ratio method; Oregon Green; rice root;
D O I
10.3117/plantroot.2.3
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
We present a simple procedure for measuring the pH in the apoplast of the rice root, using the fluorescent ratio method and Oregon Green 488 (OG). Staining with 5 mu M OG for 3 min followed by 5-min washing with calcium solution was an effective method for measuring the pH of the apoplast at the root surface. Diffusion of OG from the apoplast could be prevented by circulating a low concentration of OG (0.02 mu M) in the root vessel. However, aluminum ions disturbed the pH measurement. In the presence of 50 mu M AICI(3), the pH value was inaccurate at values higher than pH 5.0.
引用
收藏
页码:3 / 6
页数:4
相关论文
共 50 条
  • [21] Measurement of intracellular pH in pancreatic duct cells - A new method for calibrating the fluorescence data
    Hegyi, P
    Rakonczay, Z
    Gray, MA
    Argent, BE
    [J]. PANCREAS, 2004, 28 (04) : 427 - 434
  • [22] The surface pH measurement of root canal sealers
    Huang, TH
    Kao, CT
    Chou, MY
    [J]. JOURNAL OF DENTAL RESEARCH, 1997, 76 : 459 - 459
  • [23] pH biosensing in the plant apoplast-a focus on root cell elongation (vol 187, pg 504, 2021)
    Moreau, Hortense
    Zimmermann, Sabine D.
    Gaillard, Isabelle
    Paris, Nadine
    [J]. PLANT PHYSIOLOGY, 2021, 187 (04) : 2878 - 2878
  • [24] A simple estimation method of photosynthetic condition based on pH measurement using ISFET sensor
    Teramoto, Akira
    Yamada, Akira
    [J]. 2013 INTERNATIONAL SYMPOSIUM ON MICRO-NANOMECHATRONICS AND HUMAN SCIENCE (MHS), 2013,
  • [25] RATIO METHOD FOR FLUORESCENCE SPECTRAL DECONVOLUTION
    FOGARTY, MP
    WARNER, IM
    [J]. ANALYTICAL CHEMISTRY, 1981, 53 (02) : 259 - 265
  • [26] Daily non-invasive fluorescence ratio measurement of platelet concentrate pH can detetect the presence of bacteria
    Barker, L. M.
    Nanassy, O. Z.
    Reed, M. W.
    Geelhood, S. J.
    Pfalzgraf, R. D.
    Cangelosi, G. A.
    [J]. TRANSFUSION, 2006, 46 (09) : 54A - 54A
  • [27] METHOD OF MEASUREMENT OF THE CARDIOTHORACIC RATIO
    HOEFFEL, JC
    HARMAND, D
    WORMS, AM
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1990, 11 (03) : 200 - 202
  • [28] METHOD OF MEASUREMENT OF THE CARDIOTHORACIC RATIO
    HOEFFEL, JC
    HARMAND, D
    WORMS, AM
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1990, 21 (02): : 86 - 88
  • [29] A SIMPLIFIED METHOD OF PH MEASUREMENT
    WARD, RJ
    DANZIGER, F
    ALLEN, GD
    STEVENS, JH
    [J]. SURGERY, 1966, 59 (04) : 527 - &
  • [30] A novel and simple fluorescence method for the measurement of presynaptic vesicular zinc release in acute hippocampal slices with a fluorescence plate reader
    Datki, Zsolt L.
    Hunya, Akos
    Penke, Botond
    [J]. BRAIN RESEARCH BULLETIN, 2007, 74 (1-3) : 183 - 187