GEOMETRIC CHARACTERISATION AND OUT-OF-PLANE SEISMIC STABILITY OF LOW-RISE UNREINFORCED BRICK MASONRY BUILDINGS IN AUCKLAND, NEW ZEALAND

被引:21
|
作者
Walsh, Kevin Q. [1 ,2 ]
Dizhur, Dmytro Y. [1 ]
Almesferl, Nasser [1 ]
Cummuskey, Patrick A. [2 ]
Cousins, Jim [3 ]
Derakhshan, Hossein [4 ]
Griffith, Michael C. [4 ]
Ingham, Jason M. [1 ]
机构
[1] Univ Auckland, Dept Civil & Environm Engn, Auckland, New Zealand
[2] Auckland Council, Auckland, New Zealand
[3] GNS Sci, Wellington, New Zealand
[4] Univ Adelaide, Sch Civil Environm & Min Engn, Adelaide, SA, Australia
关键词
Earthquakes;
D O I
10.5459/bnzsee.47.2.139-156
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The 2010-2011 Canterbury earthquakes and corresponding Royal Commission reports have resulted in changes to the legislative environment and led to increased public awareness in New Zealand of the earthquake performance of unreinforced masonry (URM) buildings. As a result, building regulators, owners, tenants, users and heritage stakeholders will be facing a unique challenge in the near future where assessments, improvements and demolitions of URM buildings are expected to occur at an unusually high rate. Auckland is the largest city in New Zealand and because of the relative prosperity of Auckland during the period 1880-1935 when most URM buildings were being constructed in New Zealand, the city has the largest number of URM buildings in the country. Identifying those buildings most at seismic risk in Auckland's large and varied building stock has warranted a rapid field assessment program supplemented by strategically chosen detailed assessments. Information that can be procured through rapid field inspections includes the building geometric typologies (e.g., heights, building footprint geometry and isolated versus row configuration), elevation type (e.g., perforated frame versus solid wall), wall construction (e.g., solid versus cavity, number of leaves) and basic construction material type (e.g., clay brick versus stone). Furthermore, investigation into the architectural history, heritage status and functional usage of Auckland's URM buildings will affect the direction of retrofit strategies and priorities. As the owner of a large and varied portfolio of URM buildings as well as the local organisation responsible for assessing building safety, Auckland Council is developing exemplar inspection, assessment, prioritisation and retrofit strategies that will target the seismic risks associated with URM buildings, in particular, so as to preserve and enhance safety and the economic and community value of these special buildings. Collaboration amongst Auckland Council, The University of Auckland and GNS Science has resulted in a state-of-the-art rapid quantitative assessment program applied to a sampling of typologically representative URM buildings in Auckland.
引用
收藏
页码:139 / 156
页数:18
相关论文
共 50 条
  • [21] Experimental and analytical investigation of the seismic out-of-plane behavior of unreinforced masonry walls
    Loenhoff, Moritz
    Helm, Lukas
    Sadegh-Azar, Hamid
    MAUERWERK, 2020, 24 (03) : 124 - 136
  • [22] Investigation of the Geometric Variation Effect on Seismic Performance of Low-Rise Unreinforced Masonry Structures Through Fragility Analysis
    Joonam Park
    International Journal of Civil Engineering, 2018, 16 : 93 - 106
  • [23] Seismic fragility of regular masonry buildings for in-plane and out-of-plane failure
    Karantoni, Fillitsa
    Tsionis, Georgios
    Lyrantzaki, Foteini
    Fardis, Michael N.
    EARTHQUAKES AND STRUCTURES, 2014, 6 (06) : 689 - 713
  • [24] A model for the out-of-plane dynamic analysis of unreinforced masonry walls in buildings with flexible diaphragms
    Landi, Luca
    Gabellieri, Rocco
    Diotallevi, Pier Paolo
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2015, 79 : 211 - 222
  • [25] Applicability of nonlinear static procedures for low-rise unreinforced masonry buildings with flexible diaphragms
    Nakamura, Yasuto
    Derakhshan, Hossein
    Griffith, Michael C.
    Magenes, Guido
    Sheikh, Abdul H.
    ENGINEERING STRUCTURES, 2017, 137 : 1 - 18
  • [26] Natural Fibers for Out-of-Plane Strengthening Interventions of Unreinforced Masonry Buildings in Aggregate Configuration
    Cima, Valentina
    Bartolomeo, Chiara
    Grande, Ernesto
    Imbimbo, Maura
    SUSTAINABILITY, 2022, 14 (16)
  • [27] Trilinear Model for the Out-of-Plane Seismic Assessment of Vertically Spanning Unreinforced Masonry Walls
    Godio, Michele
    Beyer, Katrin
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (12)
  • [28] Effect of out-of-plane behavior on seismic fragility of masonry buildings in Turkey
    Ceran, Hasan Burak
    Erberik, Murat Altug
    BULLETIN OF EARTHQUAKE ENGINEERING, 2013, 11 (05) : 1775 - 1795
  • [29] Evaluating the seismic out-of-plane capacity of unreinforced masonry walls: effects of cantilevered masses
    Helm, Lukas
    Sadegh-Azar, Hamid
    KERNTECHNIK, 2025, 90 (01) : 2 - 10
  • [30] Displacement-based seismic analysis for out-of-plane bending of unreinforced masonry walls
    Doherty, K
    Griffith, MC
    Lam, N
    Wilson, J
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2002, 31 (04): : 833 - 850