A MULTICENTER RANDOMIZED TRIAL COMPARING A PERCUTANEOUS COLLAGEN HEMOSTASIS DEVICE WITH CONVENTIONAL MANUAL COMPRESSION AFTER DIAGNOSTIC ANGIOGRAPHY AND ANGIOPLASTY

被引:166
|
作者
SANBORN, TA
GIBBS, HH
BRINKER, JA
KNOPF, WD
KOSINSKI, EJ
ROUBIN, GS
机构
[1] JOHNS HOPKINS UNIV HOSP, BALTIMORE, MD USA
[2] ST JOSEPHS HOSP ATLANTA, ATLANTA, GA USA
[3] ST VINCENTS HOSP, BRIDGEPORT, CT USA
[4] UNIV ALABAMA, BIRMINGHAM, AL USA
关键词
D O I
10.1016/0735-1097(93)90529-A
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. A new percutaneous collagen hemostasis device was compared with conventional compression techniques after diagnostic catheterization and angioplasty. Background. peripheral vascular complications after diagnostic catheterization or more complex interventional procedures, as well as the discomfort of manual compression and prolonged bed rest, represent significant morbidity for invasive cardiac procedures. Methods. A prospective, multicenter, randomized trial was designed to compare the hemostasis time in minutes and the incidence of vascular complications in patients receiving a vascular hemostasis device with those undergoing conventional compression techniques. Results. After diagnostic catheterization, hemostasis time was significantly less with the vascular hemostasis device than with conventional manual compression (4.1 +/- 2.8 min [n = 90 patients] vs. 17.6 +/- 9.2 min [n = 75], p < 0.0001). This difference was greater in patients undergoing angioplasty and was unrelated to the anticoagulation status (4.3 +/- 3.7 min [n = 71 not receiving heparin], 7.6 +/- 11.6 min [n = 85 receiving heparin], 33.6 +/- 24.2 min [n = 134 control patients not receiving heparin], p < 0.0001 vs. control patients). The time from the start of the procedure to ambulation was slightly less after diagnostic catheterization in patients treated with the device (13.3 +/- 12.1 h vs. 19.2 +/- 17.8 h, p < 0.05). It was also less in patients who underwent angioplasty when the device was used after discontinuation of anticoagulation (23.0 +/- 11.1 h, withoutheparin), as compared with control compression techniques (32.7 +/- 18.8 h, p < 0.0001). Time to ambulation was even shorter (16.1 +/- 11.1 h, p < 0.0001) in patients in whom the device was placed immediately after angioplasty while they were still fully anticoagulated with a prolonged activated clotting time (336 +/- 85 s). There were no major complications (surgery or transfusion) after diagnostic catheterization and a low incidence of major complications in patients who underwent angioplasty (0.7% in control patients, 1.4% with the device without heparin, 1.2% with the device and heparin, p = NS). After angioplasty, there was a trend toward fewer hematomas when the device was used in the absence of heparin (4.2% vs. 9.7% in control patients, p = 0.14). Conclusions. A new vascular hemostasis device can significantly reduce the puncture site hemostasis time and the time to ambulation without significantly increasing the risk of peripheral vascular complications. The role of this technology in reducing complications, length of hospital stay and cost remains to he determined.
引用
收藏
页码:1273 / 1279
页数:7
相关论文
共 50 条
  • [31] The efficacy and safety of a hemostatic puncture closure device with early ambulation after coronary angiography: a prospective, randomized multicenter trial
    Ward, SR
    Silver, MJ
    Casale, P
    Raymond, R
    Kussmaul, W
    Simpfendorfer, C
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 : TC259 - TC259
  • [32] RAPID ARTERIAL HEMOSTASIS AND DECREASED ACCESS SITE COMPLICATIONS AFTER CARDIAC-CATHETERIZATION AND ANGIOPLASTY - RESULTS OF A RANDOMIZED TRIAL OF A NOVEL HEMOSTATIC DEVICE
    KUSSMAUL, WG
    BUCHBINDER, M
    WHITLOW, PL
    AKER, UT
    HEUSER, RR
    KING, SB
    KENT, KM
    LEON, MB
    KOLANSKY, DM
    SANDZA, JG
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (07) : 1685 - 1692
  • [33] Arterial puncture site management after percutaneous transluminal procedures using a hemostatic wound dressing (Clo-Sur PAD) versus conventional manual compression: A randomized controlled trial
    Mlekusch, W
    Dick, P
    Haurner, M
    Sabeti, S
    Minar, E
    Schillinger, M
    JOURNAL OF ENDOVASCULAR THERAPY, 2006, 13 (01) : 23 - 31
  • [34] A Multicenter Randomized Control Trial Comparing a Novel Intramedullary Device (InterTAN) Versus Conventional Treatment (Sliding Hip Screw) of Geriatric Hip Fractures
    Sanders, David
    Bryant, Dianne
    Tieszer, Christina
    Lawendy, Abdel-Rahman
    MacLeod, Mark
    Papp, Steven
    Liew, Allan
    Viskontas, Darius
    Coles, Chad
    Gurr, Kevin
    Carey, Tim
    Gofton, Wade
    Bailey, Chris
    Bartley, Debra
    Trenholm, Andrew
    Stone, Trevor
    Leighton, Ross
    Foxall, Julia
    Zomar, Mauri
    Trask, Kelly
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (01) : 1 - 8
  • [35] EVALUATION OF KETANSERIN IN THE PREVENTION OF RESTENOSIS AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - A MULTICENTER RANDOMIZED DOUBLE-BLIND PLACEBO-CONTROLLED TRIAL
    SERRUYS, PW
    KLEIN, W
    TIJSSEN, JPG
    RUTSCH, W
    HEYNDRICKX, GR
    EMANUELSSON, H
    BALL, SG
    DECOSTER, O
    SCHROEDER, E
    LIBERMAN, H
    EICHHORN, E
    WILLERSON, JT
    ANDERSON, HV
    KHAJA, F
    ALEXANDER, RW
    BAIM, D
    MELKERT, R
    VANOENE, JC
    VANGOOL, R
    CIRCULATION, 1993, 88 (04) : 1588 - 1601
  • [36] Randomized trial comparing immediate sheath removal reversing heparin with protamine versus late conventional sheath removal after elective coronary angioplasty
    Marchetti, G
    Lavaggi, D
    Ruiz, AS
    Fernández, J
    Arellano, J
    Kantor, P
    Iglesias, R
    Ferreyra, R
    Pocovi, A
    Palacios, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 32B - 32B
  • [37] Closure of Large Percutaneous Access Sites After Balloon Aortic Valvuloplasty Using a Suture Based Closure Device vs. Collagen Based Closure Device vs, Manual Compression
    Ben-Dor, Erik
    Satler, Lowell P.
    Richard, Augusto D.
    Maluenda, Gabriel
    Gagila, Michael A.
    Syed, Asmtr
    Gonzalez, Manuel A.
    Mahmoudi, Mali
    Wakabayashi, Kohei
    Belle, Loic
    Torguson, Rebecca
    Petros, Okubagzi
    Xue, Zhenyi
    Bernardo, Nelson
    Gatlin, Robert
    Suddath, William O.
    Kent, Kenneth M.
    Lindsay, Joseph
    Waksman, Ron
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (13) : B113 - B113
  • [38] Comparison of MynxGrip vascular closure device and manual compression for closure after femoral access angiography: a randomized controlled trial: the closure devices used in every day practice study, CLOSE-UP III trial
    Jakobsen, Lars
    Holm, Niels R.
    Maeng, Michael
    Thim, Troels
    Kristensen, Steen D.
    Mogensen, Lone H.
    Christiansen, Evald H.
    BMC CARDIOVASCULAR DISORDERS, 2022, 22 (01)
  • [39] Comparison of MynxGrip vascular closure device and manual compression for closure after femoral access angiography: a randomized controlled trial: the closure devices used in every day practice study, CLOSE-UP III trial
    Lars Jakobsen
    Niels R. Holm
    Michael Maeng
    Troels Thim
    Steen D. Kristensen
    Lone H. Mogensen
    Evald H. Christiansen
    BMC Cardiovascular Disorders, 22
  • [40] The Duett Arterial Closure Device vs. manual compression after diagnostic and interventional procedures: Results of the SEAL trial ultrasound substudy.
    Sanborn, TA
    Feldman, T
    Ellis, SG
    Mooney, MR
    Leimgruber, PP
    Levine, D
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (6A): : 51P - 51P