A NEW APPARATUS FOR THE DETERMINATION OF THE EMITTED DOSE FROM PRESSURIZED METERED-DOSE INHALATION AEROSOLS WITH INHALATION DEVICES

被引:2
|
作者
GADDIPATI, N
GRAZIOSI, M
GANESAN, M
机构
[1] Medical Research Division American Cyanamid Company, Pearl River, NY
关键词
D O I
10.3109/03639049509063028
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
A new in vitro test apparatus is described in this report to test the emitted dose from the pressurized metered dose inhalation aerosols (MDI) with inhalation devices. Drug deposition from MDIs in conjunction with different inhalation chambers was studied using a new apparatus and compendial apparatuses. The new apparatus is simple and offers an alternate method to determine the small particle fraction delivered from MDI aerosols with inhalation devices.
引用
收藏
页码:1399 / 1409
页数:11
相关论文
共 50 条
  • [31] Inhalation therapy in asthma:: Nebulizer or pressurized metered-dose inhaler with holding chamber?: In vivo comparison of lung deposition in children
    Wildhaber, JH
    Dore, ND
    Wilson, JM
    Devadason, SG
    LeSouëf, PN
    JOURNAL OF PEDIATRICS, 1999, 135 (01): : 28 - 33
  • [32] A novel apparatus for the determination of solubility in pressurized metered dose inhalers
    Traini, Daniela
    Young, Paul M.
    Price, Robert
    Rogueda, Phillipe
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2006, 32 (10) : 1159 - 1163
  • [33] Budesonide/Formoterol Pressurized Metered-Dose Inhaler
    Katherine A. Lyseng-Williamson
    Dene Simpson
    Drugs, 2008, 68 : 1855 - 1864
  • [34] Budesonide/formoterol pressurized metered-dose inhaler
    Lyseng-Willianison, Katherine A.
    Simpson, Dene
    DRUGS, 2008, 68 (13) : 1855 - 1864
  • [35] Characterization of the Spray Velocities from a Pressurized Metered-Dose Inhaler
    Crosland, Brian Michael
    Johnson, Matthew Ronald
    Matida, Edgar Akio
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2009, 22 (02) : 85 - 97
  • [36] Theoretical investigation of the spray from a pressurized metered-dose inhaler
    Dunbar, CA
    Watkins, AP
    Miller, JF
    ATOMIZATION AND SPRAYS, 1997, 7 (04) : 417 - 436
  • [37] The bronchoprotective efficacy of salbutamol inhaled from a new metered-dose powder inhaler compared with a conventional pressurized metered-dose inhaler connected to a spacer
    Seppala, OP
    Herrala, J
    Hedman, J
    Alanko, K
    Liipo, K
    Terho, E
    Pietinalho, A
    Nyholm, JE
    Nieminen, MM
    RESPIRATORY MEDICINE, 1998, 92 (03) : 578 - 583
  • [38] SIZE ASPECTS OF METERED-DOSE INHALER AEROSOLS
    KIM, CS
    TRUJILLO, D
    SACKNER, MA
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1985, 132 (01): : 137 - 142
  • [39] TESTS FOR FOREIGN PARTICLES IN METERED-DOSE AEROSOLS
    LEA, AR
    DREW, RM
    WONG, SSL
    HAILEY, DM
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 1982, 34 (04) : 225 - 229
  • [40] INVITRO DOSE SAMPLING FROM PRESSURIZED INHALATION AEROSOLS - INVESTIGATION OF PROCEDURES IN BPC AND NF
    MOREN, F
    JACOBSSON, SE
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1979, 3 (06) : 335 - 340