REPEATABILITY OF SUBJECTIVE AND OBJECTIVE REFRACTION

被引:2
|
作者
ROSENFIELD, M
CHIU, NN
机构
关键词
AUTOREFRACTOR; REPEATABILITY; REFRACTIVE ERROR; SUBJECTIVE REFRACTION;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Although several studies have examined the repeatability of objective refraction, data concerning the repeatability of subjective refraction under masked conditions, i.e., where the examiner is unaware of the refractive results, are limited. Accordingly, the present study compared the variability of both subjective and objective refractive techniques. Refractive error was measured in 12 subjects on 5 separate occasions. Conventional subjective procedures were used, with the exception that the sphere power scale on the phoropter was covered so that the examiner was unaware of the final result. Objective measurements were obtained using a Canon Autoref R-1 infrared autorefractor. The standard deviation (SD) of the five examinations was calculated for each individual and the mean values for the population sample determined. The mean SD's for the subjective and objective techniques were +/-0.14 and +/-0.18 D, indicating 95% confidence limits of +/-0.27 and +/-0.35 D, respectively. It is concluded that with either assessment technique, a change in refractive error of at least +/-0.50 D should be adopted as the minimum significant shift in refractive status.
引用
收藏
页码:577 / 579
页数:3
相关论文
共 50 条
  • [31] Repeatability, Reproducibility, and Comparability of Subjective and Objective Measurements of Intraocular Forward Scattering in Healthy Subjects
    Iijima, Ayaka
    Shimizu, Kimiya
    Kobashi, Hidenaga
    Saito, Aya
    Kamiya, Kazutaka
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [32] A Comparison between Automated Subjective Refraction and Traditional Subjective Refraction in Keratoconus Patients
    Carracedo, Gonzalo
    Carpena-Torres, Carlos
    Pastrana, Cristina
    Privado-Aroco, Ana
    Serramito, Maria
    Espinosa-Vidal, Teresa Maria
    Rodriguez-Lafora, Maria
    OPTOMETRY AND VISION SCIENCE, 2021, 98 (06) : 597 - 604
  • [33] Repeatability and heritability of objective and subjective fleece traits and body weight in South African Angora goats
    Snyman, MA
    Olivier, JJ
    SMALL RUMINANT RESEARCH, 1999, 34 (02) : 103 - 109
  • [34] Objective Refraction - Retinoscopy
    Buser, A.
    AUGENHEILKUNDE UP2DATE, 2014, 4 (03) : 179 - 194
  • [35] OBJECTIVE AUTOMATIC REFRACTION
    JUNGE, J
    OPHTHALMOLOGICA, 1979, 178 (1-2) : 88 - 88
  • [36] Comparisons of wavefront refraction, autorefraction, and subjective manifest refraction
    Lin, Hong-Zin
    Chen, Chien-Chung
    Lee, Yuan-Chieh
    TZU CHI MEDICAL JOURNAL, 2013, 25 (01): : 43 - 46
  • [37] The precision of wavefront refraction compared to subjective refraction and autorefraction
    Pesudovs, Konrad
    Parker, Katrina E.
    Cheng, Han
    Applegate, Raymond A.
    OPTOMETRY AND VISION SCIENCE, 2007, 84 (05) : 387 - 392
  • [38] The Pentacam® AXI, Wave provides a reliable wavefront-based objective refraction when compared to manifest subjective refraction: A prospective study
    Balparda, Kepa
    Acevedo-Urrego, Andrea
    Silva-Quintero, Laura
    Herrera-Chalarca, Tatiana
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (05) : 1533 - +
  • [39] Repeatability of refraction and corrected visual acuity in keratoconus
    Davis, LJ
    Schechtman, KB
    Begley, CG
    Shin, JA
    Zadnik, K
    OPTOMETRY AND VISION SCIENCE, 1998, 75 (12) : 887 - 896
  • [40] Subjective Refraction - Monocular Alignment
    von Livonius, Bettina
    AUGENHEILKUNDE UP2DATE, 2021, 11 (03) : 195 - 200