TIME-RESOLVED CRYOELECTRON MICROSCOPY OF VITRIFIED MUSCULAR COMPONENTS

被引:26
|
作者
LEPAULT, J [1 ]
ERK, I [1 ]
NICOLAS, G [1 ]
RANCK, JL [1 ]
机构
[1] CNRS, TECHNOL LAB, F-75005 PARIS, FRANCE
关键词
TIME-RESOLVED MICROSCOPY; CRYOELECTRON MICROSCOPY; CRYO SUBSTITUTION; VITRIFIED BIOLOGICAL SPECIMEN; ACTIN STRUCTURE; MUSCLE STRUCTURE;
D O I
10.1111/j.1365-2818.1991.tb03072.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
Biological objects may be arrested in defined stages of their activity by fast freezing and may then be structurally examined. If the time between the start of activity and freezing is controlled, structural rearrangements due to biological function can be determined. Cryo-electron microscopy shows great potential for the study of such time-dependent phenomena. This study examines the actin polymerization process using cryo-electron microscopy of vitrified specimens. Actin filaments are shown to undergo a structural change during polymerization. In the early stages of the polymerization process (t < 2 min), filaments exhibit a pronounced structural variation and frequently show a central low-density area. In the later stages of the polymerization, F-actin-ADP filaments have a more uniform appearance and rarely display a central low-density area. These findings, analysed on the basis of a previously proposed polymerization model, suggest that polymerization intermediates (F-actin-ATP and more probably F-actin-ADP-P(i)) and filaments at steady state (F-actin-ADP) have different structures. To investigate the physiological relevance of these results at the cellular level, the potential of cryo-substitution in preserving the structure of muscular fibre was assessed. Optical diffraction patterns of relaxed and contracted frog cutaneous muscle are similar to the corresponding X-ray diffraction patterns. The resolution of the images extends to about 7 nm. These results show that dynamic study of muscle contraction is possible using cryo-substitution.
引用
收藏
页码:47 / 57
页数:11
相关论文
共 50 条
  • [41] Angular spectrum approach to time-resolved acoustic microscopy
    Titov, SA
    Maev, RG
    ACOUSTICAL IMAGING, VOL 25, 2000, 25 : 247 - 252
  • [42] Using Time-Resolved Microscopy to Investigate Subcellular Hyperthermia
    Markova, I. V.
    Ryabova, A. V.
    Pominova, D. V.
    Romanishkin, I. D.
    Linkov, K. G.
    PHYSICS OF ATOMIC NUCLEI, 2024, 87 (11) : 1754 - 1758
  • [43] NANOSECONDS TIME-RESOLVED REFLECTION ELECTRON-MICROSCOPY
    BOSTANJOGLO, O
    HEINRICHT, F
    EUREM 88, VOLS 1-3: TUTORIALS, INSTRUMENTATION AND TECHNIQUES / PHYSICS AND MATERIALS / BIOLOGY, 1988, 93 : 91 - 92
  • [44] Time-Resolved Microscopy: A New Frontier in Physical Chemistry
    Huang, Libai
    Wong, Cathy
    Grumstrup, Erik
    JOURNAL OF PHYSICAL CHEMISTRY A, 2020, 124 (29): : 5997 - 5998
  • [45] TIME-RESOLVED CATHODOLUMINESCENCE IN SCANNING ELECTRON MICROSCOPY.
    Hastenrath, M.
    Kubalek, E.
    Scanning Electron Microscopy, 1982, (pt 1) : 157 - 173
  • [46] Monitoring of microvascular calcification by time-resolved photoacoustic microscopy
    Ma, Haigang
    Yu, Yinshi
    Zhu, Yahui
    Wu, Hongjun
    Qiu, Haixia
    Gu, Ying
    Chen, Qian
    Zuo, Chao
    PHOTOACOUSTICS, 2025, 41
  • [47] Time-resolved electron microscopy by means of electron counting
    Osakabe, N
    Kodama, T
    Tonomura, A
    PHYSICAL REVIEW B, 1997, 56 (09): : 5156 - 5163
  • [48] Microsecond time-resolved cryo-electron microscopy
    Lorenz, Ulrich J.
    CURRENT OPINION IN STRUCTURAL BIOLOGY, 2024, 87
  • [49] Pitfalls and their remedies in time-resolved fluorescence spectroscopy and microscopy
    vandeVen, M
    Ameloot, M
    Valeur, B
    Boens, N
    JOURNAL OF FLUORESCENCE, 2005, 15 (03) : 377 - 413
  • [50] Time-resolved scanning tunnelling microscopy for molecular science
    Sloan, P. A.
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2010, 22 (26)