Evaluation of Filtering Bleb Function after Trabeculectomy with Mitomycin C Using Biomicroscopy, Anterior Segment Optical Coherence Tomography and In Vivo Confocal Microscopy

被引:11
|
作者
Yilmaz, Suzan Guven [1 ]
Degirmenci, Cumali [1 ]
Palamar, Melis [1 ]
Yagci, Ayse [1 ]
机构
[1] Ege Univ, Fac Med, Dept Ophthalmol, Izmir, Turkey
关键词
Bleb; biomicroscopy; anterior segment optical coherence tomography; in vivo confocal microscopy;
D O I
10.4274/tjo.29052
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To analyze and assess compatibility of trabeculectomy filtering bleb characteristics and appearances using biomicroscopy, anterior segment optical coherence tomography (AS-OCT) and in vivo confocal microscopy (IVCM). Materials and Methods: Twenty-eight eyes of 28 patients who underwent glaucoma filtering surgery with mitomycin C in our clinic between 2009 and 2013 were evaluated. Morphological appearances of the blebs on slit-lamp biomicroscopy were defined according to the Moorfields bleb classification system. For the internal tissue assessment of blebs, AS-OCT and IVCM were performed. Bleb biometric parameters such as length, height and bleb wall thickness were assessed by AS-OCT; conjunctival epithelial-stromal cyst, structural network of conjunctival stroma and vascularisation were examined with IVCM. The relation between biomicroscopic morphological staging and bleb characteristics detected on AS-OCT and IVCM were assessed. Results: The mean age of the 28 patients (16 male, 12 female) was 57.2 +/- 15.9 (19 to 79) years. The mean time elapsed between surgery and examination was 29.2 +/- 19.2 (6 to 68) months. According to biomicroscopic appearance, 17 (60.7%) blebs were functional (13 diffuse, 4 microcystic), whereas 11 (39.3%) blebs were non-functional (9 flat, 2 encapsulated). In the comparison of non-functional and functional blebs, functional blebs were found to be superior in terms of biometric parameters on AS-OCT assessment (p<0.05). Higher number of epithelial and stromal cysts and less vascularisation were detected by IVCM in functional blebs when compared with non-functional blebs (p<0.05). Conclusion: Biomicroscopic appearances and characteristics on AS-OCT and IVCM of filtration blebs are consistent with each other. Besides biomicroscopic examination, which is an easy and practical method for determining bleb morphology, cross-sectional images obtained by AS-OCT and IVCM provide objective data regarding internal structure and functional features of blebs.
引用
收藏
页码:132 / 137
页数:6
相关论文
共 50 条
  • [31] Comment on "Comparison of Anterior Segment Optical Coherence Tomography Bleb Grading, Moorfields Bleb Grading System, and Intraocular Pressure After Trabeculectomy"
    Ermerak, Basak Can
    Baykara, Mehmet
    Ozcetin, Hikmet
    JOURNAL OF GLAUCOMA, 2017, 26 (10) : E242 - E243
  • [32] Quantitative analysis of filtering blebs using optical coherence tomography following trabeculectomy with mitomycin C
    Mori, K
    Kawashima, A
    Kobayashi, L
    Kinoshita, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S5 - S5
  • [33] Epithelial barrier function of the filtering bleb conjunctiva and the cornea after trabeculectomy with mitomycin C
    Taniguchi, T
    Yamamoto, T
    Mochizuki, K
    Haque, MSR
    Kitazawa, Y
    Yokoi, N
    Komuro, A
    Kinoshita, S
    JOURNAL OF GLAUCOMA, 1996, 5 (04) : 233 - 236
  • [34] Anterior segment optical coherence tomography imaging and histopathologic findings of an overhanging filtering bleb
    W K Kim
    G J Seong
    C S Lee
    Y G Kim
    C Y Kim
    Eye, 2008, 22 : 1520 - 1521
  • [35] Anterior segment optical coherence tomography imaging and histopathologic findings of an overhanging filtering bleb
    Kim, W. K.
    Seong, G. J.
    Lee, C. S.
    Kim, Y. G.
    Kim, C. Y.
    EYE, 2008, 22 (12) : 1520 - 1521
  • [36] In Vivo Evaluation of the Limbus Using Anterior Segment Optical Coherence Tomography
    Le, Qihua
    Cordova, Daniel
    Xu, Jianjiang
    Deng, Sophie X.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (04):
  • [37] Imaging of trabeculectomy blebs using anterior segment optical coherence tomography
    Singh, Mandeep
    Chew, Paul T. K.
    Friedman, David S.
    Nolan, Winifred P.
    See, Jovina L.
    Smith, Scott D.
    Zheng, Ce
    Foster, Paul J.
    Aung, Tin
    OPHTHALMOLOGY, 2007, 114 (01) : 47 - 53
  • [38] Morphology of Trabeculectomy Filtering Blebs using Anterior Segment Optical Coherence Tomography: A Comparison of Two Methods
    Proenca, Rita Pinto
    Ferreira, Joana
    Cunha, Joao Paulo
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON PHOTONICS, OPTICS AND LASER TECHNOLOGY (PHOTOPTICS), 2017, : 414 - 419
  • [39] Morphology of trabeculectomy filtering blebs using anterior segment optical coherence tomography: a comparison of two methods
    Proenca, Rita
    Cunha, Joao Paulo
    Ferreira, Joana
    Santos, Arnaldo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (11)
  • [40] Measurement of Corneal and Limbal Epithelial Thickness by In Vivo Confocal Microscopy and Anterior Segment Optical Coherence Tomography
    Le, Qihua
    Chen, Yan
    Yang, Yujing
    Xu, JianJiang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)