Evaluation of Filtering Bleb Function after Trabeculectomy with Mitomycin C Using Biomicroscopy, Anterior Segment Optical Coherence Tomography and In Vivo Confocal Microscopy

被引:11
|
作者
Yilmaz, Suzan Guven [1 ]
Degirmenci, Cumali [1 ]
Palamar, Melis [1 ]
Yagci, Ayse [1 ]
机构
[1] Ege Univ, Fac Med, Dept Ophthalmol, Izmir, Turkey
关键词
Bleb; biomicroscopy; anterior segment optical coherence tomography; in vivo confocal microscopy;
D O I
10.4274/tjo.29052
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To analyze and assess compatibility of trabeculectomy filtering bleb characteristics and appearances using biomicroscopy, anterior segment optical coherence tomography (AS-OCT) and in vivo confocal microscopy (IVCM). Materials and Methods: Twenty-eight eyes of 28 patients who underwent glaucoma filtering surgery with mitomycin C in our clinic between 2009 and 2013 were evaluated. Morphological appearances of the blebs on slit-lamp biomicroscopy were defined according to the Moorfields bleb classification system. For the internal tissue assessment of blebs, AS-OCT and IVCM were performed. Bleb biometric parameters such as length, height and bleb wall thickness were assessed by AS-OCT; conjunctival epithelial-stromal cyst, structural network of conjunctival stroma and vascularisation were examined with IVCM. The relation between biomicroscopic morphological staging and bleb characteristics detected on AS-OCT and IVCM were assessed. Results: The mean age of the 28 patients (16 male, 12 female) was 57.2 +/- 15.9 (19 to 79) years. The mean time elapsed between surgery and examination was 29.2 +/- 19.2 (6 to 68) months. According to biomicroscopic appearance, 17 (60.7%) blebs were functional (13 diffuse, 4 microcystic), whereas 11 (39.3%) blebs were non-functional (9 flat, 2 encapsulated). In the comparison of non-functional and functional blebs, functional blebs were found to be superior in terms of biometric parameters on AS-OCT assessment (p<0.05). Higher number of epithelial and stromal cysts and less vascularisation were detected by IVCM in functional blebs when compared with non-functional blebs (p<0.05). Conclusion: Biomicroscopic appearances and characteristics on AS-OCT and IVCM of filtration blebs are consistent with each other. Besides biomicroscopic examination, which is an easy and practical method for determining bleb morphology, cross-sectional images obtained by AS-OCT and IVCM provide objective data regarding internal structure and functional features of blebs.
引用
收藏
页码:132 / 137
页数:6
相关论文
共 50 条
  • [1] Filtering bleb functionality: A clinical, anterior segment optical coherence tomography and in vivo confocal microscopy study
    Ciancaglini, Marco
    Carpineto, Paolo
    Agnifili, Luca
    Nubile, Mario
    Lanzini, Manuela
    Fasanella, Vincenzo
    Mastropasqua, Leonardo
    JOURNAL OF GLAUCOMA, 2008, 17 (04) : 308 - 317
  • [2] Functional evaluation of the filtering bleb by ultrasound biomicroscopy after trabeculectomy with mitomycin C
    Ali Abbas El Salhy
    Rabab Mohamed Elseht
    Ahmed Fekry Al Maria
    Saied Mohamed Abd Elwahab Shalaby
    Tarek Ragaee Hossein
    International Journal of Ophthalmology, 2018, (02) : 245 - 250
  • [3] Functional evaluation of the filtering bleb by ultrasound biomicroscopy after trabeculectomy with mitomycin C
    El Salhy, Ali Abbas
    Elseht, Rabab Mohamed
    Al Maria, Ahmed Fekry
    Shalaby, Saied Mohamed Abd El-Wahab
    Hossein, Tarek Ragaee
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2018, 11 (02) : 245 - 250
  • [4] Observation of filtering bleb after trabeculectomy using optical coherence tomography and ultrasound biomicroscopy.
    Miura, F
    Yuki, T
    Ohgushi, G
    Koike, T
    Kimura, Y
    Kishi, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S581 - S581
  • [5] Bleb Morphology After Mitomycin-C Augmented Trabeculectomy: Comparison Between Clinical Evaluation and Anterior Segment Optical Coherence Tomography
    Waibel, Soeren
    Spoerl, Eberhard
    Furashova, Olga
    Pillunat, Lutz E.
    Pillunat, Karin R.
    JOURNAL OF GLAUCOMA, 2019, 28 (05) : 447 - 451
  • [6] The Assessment of the Filtering Bleb Function With Anterior Segment Optical Coherence Tomography
    Tominaga, Akiko
    Miki, Atsuya
    Yamazaki, Yuko
    Matsushita, Kenji
    Otori, Yasumasa
    JOURNAL OF GLAUCOMA, 2010, 19 (08) : 551 - 555
  • [7] In Vivo Confocal Microscopy and Biomicroscopy of Filtering Blebs After Trabeculectomy
    Caglar, Cagatay
    Karpuzoglu, Nafiz
    Batur, Muhammed
    Yasar, Tekin
    JOURNAL OF GLAUCOMA, 2016, 25 (04) : E377 - E383
  • [8] Evaluation of Successful and Failed Filtering Blebs after Trabeculectomy Using Anterior Segment Optical Coherence Tomography
    Tekin, Serek
    Seven, Erbil
    Batur, Muhammed
    Ozer, Muhammet Derda
    Yasar, Tekin
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2021, 33 (01): : 1 - 5
  • [9] Analysis of bleb morphology after trabeculectomy with Visante anterior segment optical coherence tomography
    Leung, Christopher Kai-shun
    Yick, Doris Wai-fong
    Kwong, Yolanda Yuen-ying
    Li, Felix Chi-hong
    Leung, Dexter Yu-lung
    Mohamed, Shaheeda
    Tham, Clement Chee-yung
    Chung-chai, Chi
    Lam, Dennis Shun-Chiu
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (03) : 340 - 344
  • [10] Bleb analysis using anterior segment optical coherence tomography after trabeculectomy with amniotic membrane transplantation
    Kim, Hwayeong
    Moon, Sangwoo R.
    Kim, Eunah
    Kim, Jinmi
    Lee, Jiwoong
    PLOS ONE, 2023, 18 (05):