GPS for structural health monitoring - case study on the Basarab overpass cable-stayed bridge

被引:14
|
作者
Lepadatu, Alexandru [1 ]
Tiberius, Christian [2 ]
机构
[1] Tech Univ Civil Engn Bucharest, Fac Geodesy, Bucharest, Romania
[2] Delft Univ Technol, Fac Civil Engn & Geosci, Dept Geosci & Remote Sensing, NL-2628 CN Delft, Netherlands
关键词
GPS; Cable-stayed bridge monitoring; Detection probability; Harmonic analysis;
D O I
10.1515/jag-2013-0020
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
The Basarab cable-stayed bridge is a newly built structure in Bucharest, Romania, which was inaugurated in June 2011. Before the offcial opening, in order to assure its qualification for traffic, it had to pass several loading tests with convoys of trucks and trams. For this, besides a priori evaluation using the Finite Element Method (FEM), levelling and acceleration measurements were made to identify vertical displacements, as well as vibration frequencies of the bridge. The three-day loading trial of the bridge represented a good opportunity for setting-up a GPS campaign for structural monitoring of the Basarab bridge. Taking advantage of the redundancy obtained via simultaneous multi-sensor measurements, itwas possible to compare and validate the GPS estimated displacements with both FEM and levelling. Moreover, the dynamic behaviour of the bridge during a dynamic loading test was evaluated using a 20 Hz GPS observation rate and validated afterwards with vibration frequency estimates from acceleration time series. Along with simulations (FEM) and laboratory tests, the in situ monitoring of a structure has a particular importance in establishing the safety of a newly-built structure. Furthermore, in some cases permanent monitoring is needed for safety and economic reasons, especially for strategic structures such as dams and bridges. GPS technology can satisfy this request due to its real- time processing capability and thus it can be looked upon as a new and promising tool for dynamic evaluation of engineering structures. In this contribution we have also assessed the performance of GPS with regard to accuracy and false alarm probability demands for the continuous monitoring of the Basarab cable-stayed bridge.
引用
收藏
页码:65 / 85
页数:21
相关论文
共 50 条
  • [1] Basarab Cable-Stayed Bridge in Bucharest
    Manterola Armisen, Javier
    Martinez Cutillas, Antonio
    Fuente Garcia, Silvia
    STRUCTURAL ENGINEERING INTERNATIONAL, 2014, 24 (03) : 392 - 395
  • [2] Non-contact structural health monitoring of a cable-stayed bridge: case study
    Alamdari, Mehrisadat Makki
    Ge, Linlin
    Kildashti, Kamyar
    Zhou, Yincai
    Harvey, Bruce
    Du, Zheyuan
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2019, 15 (08) : 1119 - 1136
  • [3] STRUCTURAL HEALTH MONITORING SYSTEM OF A CONCRETE CABLE-STAYED BRIDGE
    Biliszczuk, Jan
    Hawryszkow, Pawel
    Teichgraeber, Marco
    ARCHITECTURE CIVIL ENGINEERING ENVIRONMENT, 2018, 11 (04) : 69 - 77
  • [4] Structural health monitoring system for Sutong Cable-stayed Bridge
    Wang, Hao
    Tao, Tianyou
    Li, Aiqun
    Zhang, Yufeng
    SMART STRUCTURES AND SYSTEMS, 2016, 18 (02) : 317 - 334
  • [5] Online structural monitoring of a cable-stayed bridge
    Chang, SP
    Kim, SK
    SMART SYSTEMS FOR BRIDGES, STRUCTURES, AND HIGHWAYS: SMART STRUCTURES AND MATERIALS 1996, 1996, 2719 : 150 - 158
  • [6] Structural monitoring of cable-stayed bridge: Analysis of GPS versus modeled deflections
    Watson, Christopher
    Watson, Tim
    Coleman, Richard
    JOURNAL OF SURVEYING ENGINEERING-ASCE, 2007, 133 (01): : 23 - 28
  • [7] Structural health monitoring of a long-span cable-stayed bridge
    Zhang, Guanyong
    Zhang, Zhijun
    Fischer, Chad
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2007, 18 (08) : 835 - 843
  • [8] Study on Health Monitoring System Design of Cable-Stayed Bridge
    Lin, Heng
    Xiang, Yiqiang
    Jia, Yakun
    FACING THE CHALLENGES IN STRUCTURAL ENGINEERING, 2018, : 216 - 228
  • [9] Structural health monitoring methods of cables in cable-stayed bridge: A review
    Zhang, Lixiao
    Qiu, Guoyang
    Chen, Zhishou
    MEASUREMENT, 2021, 168
  • [10] Structural health monitoring of a cable-stayed bridge with Bayesian neural networks
    Arangio, Stefania
    Bontempi, Franco
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2015, 11 (04) : 575 - 587