Structural health monitoring of a long-span cable-stayed bridge

被引:6
|
作者
Zhang, Guanyong
Zhang, Zhijun
Fischer, Chad
机构
[1] Tongji Univ, Dept Bridge Engn, Shanghai 200092, Peoples R China
[2] Univ Illinois, Dept Civil & Mat Engn, Chicago, IL 60607 USA
关键词
cable-stayed bridges; health monitoring; cable force; deformation monitoring; vibrational characteristics;
D O I
10.1177/1045389X06074568
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Proper selection of methods and instruments for structural health monitoring (SHM) of bridges will assure reliability, durability, and lower life cycle costs. This article provides a case study for in-service monitoring of a recently built long-span hybrid cablestayed bridge, Queshi Bridge, in southern China. Three parameters, namely the cable forces, main structure deformations, and their vibrations are monitored with different methods at regular intervals over a time period of about four years. The results to date are very encouraging as the SHM systems installed in the bridge have been able to provide vital information about the state of health of the bridge to the transportation authorities.
引用
收藏
页码:835 / 843
页数:9
相关论文
共 50 条
  • [1] Cable Health Monitoring System for Long-span Cable-stayed Bridge
    Gao Chao
    Li Xinke
    Guo Yongcai
    He Fuliang
    [J]. DISASTER ADVANCES, 2011, 4 : 130 - 135
  • [2] Instrumentation for durability monitoring of a long-span cable-stayed bridge
    Hua, XG
    Ni, YQ
    Zhou, HF
    Ko, JM
    [J]. Smart Structures and Materials 2005: Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace, Pts 1 and 2, 2005, 5765 : 982 - 991
  • [3] Continuous monitoring of a long-span cable-stayed timber bridge
    Saracoglu, Erhan
    Bergstrand, Sten
    [J]. JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2015, 5 (02) : 183 - 194
  • [4] HEALTH MONITORING SYSTEM OF LONG-SPAN PRESTRESSED CONCRETE CABLE-STAYED BRIDGE
    Tu, Guangya
    Yan, Donghuang
    Chen, Changsong
    [J]. INTERNATIONAL SYMPOSIUM ON LIFE-CYCLE PERFORMANCE OF BRIDGES AND STRUCTURES, 2010, : 196 - 200
  • [5] Damage Detection for Long-Span Cable-Stayed Bridge
    赵玲
    李爱群
    缪长青
    汪永兰
    [J]. Railway Engineering Science, 2006, (01) : 63 - 72
  • [6] Dynamic Characteristics of a Long-span Cable-stayed Bridge
    Hui, Liu
    [J]. MATERIALS ENGINEERING FOR ADVANCED TECHNOLOGIES, PTS 1 AND 2, 2011, 480-481 : 1496 - 1501
  • [7] Service performance evaluation of long-span cable-stayed bridge based on health monitoring data
    Zhang, Xin
    Wang, Jie
    Wang, Qiang
    Cao, Maosen
    Manoach, Emil
    [J]. JOURNAL OF VIBROENGINEERING, 2022, 24 (04) : 651 - 665
  • [8] Puqian Bridge: A Long-Span Cable-Stayed Bridge in a Meizoseismal Area
    Wu, Jingwu
    Xia, Ye
    Sun, Pingkuan
    Yu, Deen
    Sun, Limin
    [J]. STRUCTURAL ENGINEERING INTERNATIONAL, 2023, 33 (01) : 64 - 67
  • [9] The Seismic Response Analysis of Long-Span Cable-Stayed Bridge
    Niu, Yongzhe
    Guo, Wenjie
    Li, Guangling
    Sun, Ruixin
    [J]. ADVANCES IN CIVIL AND STRUCTURAL ENGINEERING III, PTS 1-4, 2014, 501-504 : 1364 - +
  • [10] Seismic Displacements Reduction for a Long-Span Cable-Stayed Bridge
    Yang, Xi-wen
    Lian, Zi-bao
    [J]. ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 840 - +