Damage Detection for Long-Span Cable-Stayed Bridge

被引:0
|
作者
赵玲 [1 ]
李爱群 [2 ]
缪长青 [2 ]
汪永兰 [2 ]
机构
[1] College of Civil Engineering, Southeast University, Nanjing 210096, China, College of Architectural Science and Engineering, Yangzhou University, Yangzhou 225009, China
[2] College of Civil Engineering, Southeast University, Nanjing 210096, China
关键词
Cable-stayed bridge; Cable damage; Girder damage; Modal curvature; Cable force;
D O I
暂无
中图分类号
U441 [结构原理、结构力学];
学科分类号
0814 ; 081406 ;
摘要
Based on the updated finite-element model of a cable-stayed bridge, this study investigates the technique of identifying damage existing in cable or girder by means of numerical simulation. The modal analysis is performed to identify the changes in modal frequencies and curvatures caused by damage, and the static analysis is executed to detect the influence of damage on cable force. The results indicate a relatively significant decrease in frequencies of lower vertical bending modes due to the damage in cable and little change of frequencies due to damage in girder. Different sensitivities to the location of damaged cable are observed from the frequency changes of different bending modes, which can be used to initially locate the damaged cable. The damage in either cable or girder can be further localized by the most significant change in curvature of girder. The damage occurred in a cable produces a remarkable change in force of nearby cables, whereas the damage in girder brings little change of cable forces. In addition, a pragmatic approach for localizing the damage in girder or cable is proposed based on a comprehensive utilization of the changes in frequency of vertical bending modes, modal curvature of girder, and force in cables.
引用
收藏
页码:63 / 72
页数:10
相关论文
共 50 条
  • [1] Simulation of the effect of temperature variation on damage detection in a long-span cable-stayed bridge
    Xu, Zhao-Dong
    Wu, Zhishen
    [J]. STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2007, 6 (03): : 177 - 189
  • [2] Dynamic Characteristics of a Long-span Cable-stayed Bridge
    Hui, Liu
    [J]. MATERIALS ENGINEERING FOR ADVANCED TECHNOLOGIES, PTS 1 AND 2, 2011, 480-481 : 1496 - 1501
  • [3] Fatigue Damage Factor Calibration for Long-Span Cable-Stayed Bridge Decks
    Nussbaumer, A.
    Pedro, J. Oliveira
    Baptista, C. A. Pereira
    Duval, M.
    [J]. MECHANICAL FATIGUE OF METALS: EXPERIMENTAL AND SIMULATION PERSPECTIVES, 2019, 7 : 369 - 376
  • [4] Cable Health Monitoring System for Long-span Cable-stayed Bridge
    Gao Chao
    Li Xinke
    Guo Yongcai
    He Fuliang
    [J]. DISASTER ADVANCES, 2011, 4 : 130 - 135
  • [5] Puqian Bridge: A Long-Span Cable-Stayed Bridge in a Meizoseismal Area
    Wu, Jingwu
    Xia, Ye
    Sun, Pingkuan
    Yu, Deen
    Sun, Limin
    [J]. STRUCTURAL ENGINEERING INTERNATIONAL, 2023, 33 (01) : 64 - 67
  • [6] Instrumentation for durability monitoring of a long-span cable-stayed bridge
    Hua, XG
    Ni, YQ
    Zhou, HF
    Ko, JM
    [J]. Smart Structures and Materials 2005: Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace, Pts 1 and 2, 2005, 5765 : 982 - 991
  • [7] The Seismic Response Analysis of Long-Span Cable-Stayed Bridge
    Niu, Yongzhe
    Guo, Wenjie
    Li, Guangling
    Sun, Ruixin
    [J]. ADVANCES IN CIVIL AND STRUCTURAL ENGINEERING III, PTS 1-4, 2014, 501-504 : 1364 - +
  • [8] Structural health monitoring of a long-span cable-stayed bridge
    Zhang, Guanyong
    Zhang, Zhijun
    Fischer, Chad
    [J]. JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2007, 18 (08) : 835 - 843
  • [9] Continuous monitoring of a long-span cable-stayed timber bridge
    Saracoglu, Erhan
    Bergstrand, Sten
    [J]. JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2015, 5 (02) : 183 - 194
  • [10] Seismic Displacements Reduction for a Long-Span Cable-Stayed Bridge
    Yang, Xi-wen
    Lian, Zi-bao
    [J]. ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 840 - +