A REVIEW OF PROTON-BEAM RADIATION-THERAPY

被引:99
|
作者
MILLER, DW
机构
[1] Department of Radiation Medicine, Loma Linda University Medical Center, Loma Linda, California
关键词
PROTONS; THERAPY HISTORY; TREATMENT DOSIMETRY; PROTON SYSTEMS; PROTON MICRODOSIMETRY;
D O I
10.1118/1.597435
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Beams of protons have been used for radiation treatment for approximately 40 years. This paper provides a short summary of activities from institutions that have contributed to the field over this period. The paper reviews some of the basic interactions of protons with matter that are relevant to radiation treatment and summarizes current knowledge pertaining to the response of biological systems to proton beam radiation. The technical means of producing and delivering proton treatment beams are discussed along with examples of the implementation of these methods at treatment facilities around the world. Finally, the clinical dosimetry of proton beams is summarized and sample data are presented.
引用
收藏
页码:1943 / 1954
页数:12
相关论文
共 50 条
  • [31] The development of proton-beam grid therapy (PBGT)
    Henry, T.
    Valdman, A.
    Siegbahn, A.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S260 - S260
  • [32] APPLICATION OF PROTON RADIATION-THERAPY
    BENNETT, GW
    LEVINE, GS
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (02): : 225 - 225
  • [33] PROTON-BEAM THERAPY AT THE HARVARD CYCLOTRON LABORATORY
    KOEHLER, AM
    SOUTH AFRICAN JOURNAL OF SCIENCE, 1982, 78 (05) : 215 - 215
  • [34] SHOULD PROTON-BEAM THERAPY BE WIDELY ADOPTED?
    Schulz, Robert J.
    Kagan, A. Robert
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (05): : 1307 - 1309
  • [35] PROTON-BEAM THERAPY FOR UVEAL MELANOMA - REPLY
    GRAGOUDAS, ES
    SEDDON, JM
    EGAN, K
    GLYNN, R
    OPHTHALMOLOGY, 1989, 96 (01) : 138 - 139
  • [36] Neovascular glaucoma following proton-beam therapy
    D'Hermies, F
    Meyer, A
    Morel, X
    Lumbroso, L
    Levy, C
    Desjardins, L
    Frau, E
    Halhal, M
    Elmaleh, C
    Berges, O
    Gauthier, JB
    Ferrand, R
    Delacroix, S
    Schlienger, P
    Schwarz, L
    Habrand, JL
    Mazeron, A
    Renard, G
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2001, 24 (01): : 95 - 101
  • [37] BROMOCRIPTINE PREPARATION OF PROLACTINOMAS FOR PROTON-BEAM THERAPY
    KLIMAN, B
    KJELLBERG, RN
    CLINICAL RESEARCH, 1983, 31 (02): : A471 - A471
  • [38] Is Proton-beam Therapy Better Than Intensity-modulated Radiation Therapy for Prostate Cancer?
    Kagan, Arthur R.
    Yeh, Jekwon
    Schulz, Robert J.
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2014, 37 (06): : 525 - 527
  • [39] SAFETY AND EFFICACY OF PROTON-BEAM RADIATION THERAPY FOR PATIENTS WITH LOCALLY RECURRENT RECTAL CANCER
    Hamauchi, S.
    Yamazaki, K.
    Yasui, H.
    Boku, N.
    Onozawa, Y.
    Fukutomi, A.
    Machida, N.
    Yokota, T.
    Todaka, A.
    Taniguchi, H.
    Tsushima, T.
    Funakoshi, T.
    Tabuse, H.
    Shibata, Y.
    ANNALS OF ONCOLOGY, 2012, 23 : 160 - 160
  • [40] PROTON-BEAM SOURCE
    AUSLENDER, VL
    LAZAREV, VN
    PANFILOV, AD
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1979, 22 (04) : 915 - 918