COBE DIFFERENTIAL MICROWAVE RADIOMETERS - CALIBRATION TECHNIQUES

被引:46
|
作者
BENNETT, CL
SMOOT, GF
JANSSEN, M
GULKIS, S
KOGUT, A
HINSHAW, G
BACKUS, C
HAUSER, MG
MATHER, JC
ROKKE, L
TENORIO, L
WEISS, R
WILKINSON, DT
WRIGHT, EL
DEAMICI, G
BOGGESS, NW
CHENG, ES
JACKSON, PD
KEEGSTRA, P
KELSALL, T
KUMMERER, R
LINEWEAVER, C
MOSELEY, SH
MURDOCK, TL
SANTANA, J
SHAFER, RA
SILVERBERG, RF
机构
[1] LAWRENCE BERKELEY LAB,BERKELEY,CA 94720
[2] NASA,GODDARD SPACE FLIGHT CTR,UNIV SPACE RES ASSOC,GREENBELT,MD 20771
[3] HUGHES STX CORP,LANHAM,MD 20706
[4] GEN RES CORP,DANVERS,MA 01923
[5] UNIV CALIF BERKELEY,SPACE SCI LAB,BERKELEY,CA 94720
[6] JET PROP LAB,PASADENA,CA 91109
[7] MIT,DEPT PHYS,CAMBRIDGE,MA 02139
[8] PRINCETON UNIV,DEPT PHYS,PRINCETON,NJ 08544
[9] UNIV CALIF LOS ANGELES,DEPT ASTRON,LOS ANGELES,CA 90024
来源
ASTROPHYSICAL JOURNAL | 1992年 / 391卷 / 02期
关键词
COSMIC MICROWAVE BACKGROUND; INSTRUMENTATION; DETECTORS;
D O I
10.1086/171363
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The COBE spacecraft was launched 1989 November 18 UT carrying three scientific instruments into Earth orbit for studies of cosmology. One of these instruments, the Differential Microwave Radiometer (DMR), is designed to measure the large-angular-scale temperature anisotropy of the cosmic microwave background radiation at three frequencies (31.5, 53, and 90 GHz). In this paper we present three methods used to calibrate the DMR. First, the signal difference between beam-filling hot and cold targets observed on the ground provides a primary calibration that is transferred to space by noise sources internal to the instrument. Second, the Moon is used in flight as an external calibration source. Third, the signal arising from the Doppler effect due to the Earth's motion around the barycenter of the solar system is used as an external calibration source. Preliminary analysis of the external source calibration techniques confirms the accuracy of the currently more precise ground-based calibration. Assuming the noise source behavior did not change from the ground-based calibration to flight we derive a 0.1%-0.4% relative and 0.7%-2.5% absolute calibration uncertainty, depending on radiometer channel.
引用
收藏
页码:466 / 482
页数:17
相关论文
共 50 条
  • [21] PRELIMINARY SEPARATION OF GALACTIC AND COSMIC MICROWAVE EMISSION FOR THE COBE DIFFERENTIAL MICROWAVE RADIOMETER
    BENNETT, CL
    SMOOT, GF
    HINSHAW, G
    WRIGHT, EL
    KOGUT, A
    DEAMICI, G
    MEYER, SS
    WEISS, R
    WILKINSON, DT
    GULKIS, S
    JANSSEN, M
    BOGGESS, NW
    CHENG, ES
    HAUSER, MG
    KELSALL, T
    MATHER, JC
    MOSELEY, SH
    MURDOCK, TL
    SILVERBERG, RF
    ASTROPHYSICAL JOURNAL, 1992, 396 (01): : L7 - &
  • [22] Calibration Method for Fully Polarimetric Microwave Radiometers Using the Correlated Noise Calibration Standard
    Peng, Jinzheng
    Ruf, Christopher S.
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2008, 46 (10): : 3087 - 3097
  • [23] Calibration techniques and devices for correlation radiometers used in polarization measurements
    Baralis, M
    Peverini, OA
    Tascone, R
    Trinchero, D
    Niculae, V
    Olivieri, A
    Carretti, E
    Cortiglioni, S
    Macculi, C
    Monari, J
    Orfei, A
    Sironi, G
    Zannoni, M
    ASTROPHYSICAL POLARIZED BACKGROUNDS, 2002, 609 : 257 - 260
  • [24] A Calibration Scheme for Microwave Radiometers Using Tipping Curves and Kalman Filtering
    Schneebeli, Marc
    Maetzler, Christian
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2009, 47 (12): : 4201 - 4209
  • [25] Stabilization of the brightness temperature of a calibration warm load for spaceborne microwave radiometers
    De Amici, Giovanni
    Layton, Ryan A.
    Brown, Shannon T.
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2007, 45 (07): : 1921 - 1927
  • [26] PLANAR METAMATERIAL ABSORBERS FOR CALIBRATION OF MICROWAVE RADIOMETERS FOR ATMOSPHERIC REMOTE SENSING
    Khatib, Omar
    Gu, Dazhen
    Smith, Jonah
    Deal, William R.
    Padilla, Willie J.
    Reising, Steven C.
    2022 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS 2022), 2022, : 7214 - 7217
  • [27] Inter-Calibration of Microwave Radiometers Using the Vicarious Cold Calibration Double Difference Method
    Kroodsma, Rachael A.
    McKague, Darren S.
    Ruf, Christopher S.
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2012, 5 (03) : 1006 - 1013
  • [28] A correlated noise calibration standard for interferometric, polarimetric, and autocorrelation microwave radiometers
    Ruf, CS
    Li, JK
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2003, 41 (10): : 2187 - 2196
  • [29] Analysis and improvement of tipping calibration for ground-based microwave radiometers
    Han, Y
    Westwater, ER
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2000, 38 (03): : 1260 - 1276
  • [30] ANGULAR POWER SPECTRUM OF THE MICROWAVE BACKGROUND ANISOTROPY SEEN BY THE COBE DIFFERENTIAL MICROWAVE RADIOMETER
    WRIGHT, EL
    SMOOT, GF
    BENNETT, CL
    LUBIN, PM
    ASTROPHYSICAL JOURNAL, 1994, 436 (02): : 443 - 451